Abdusshakur Muhammad Auwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdusshakur Muhammad Auwal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Callum Cook
Institute of Infection, Veterinary and Ecological Science, University of Liverpool, Liverpool, UK
2 shared publications - Mark Ellul
Institute of Infection, Veterinary and Ecological Science, University of Liverpool, Liverpool, UK
2 shared publications - Ava Easton
Institute of Infection, Veterinary and Ecological Science, University of Liverpool, Liverpool, UK
1 shared publication Benedict D Michael
Institute of Infection, Veterinary and Ecological Science, University of Liverpool, Liverpool, UK
1 shared publication- Benedict Daniel Michael
The Brain Infection and Inflammation Group, Liverpool Interdisciplinary Neuroscience Centre (LINC), Clinical Infection, Microbiology, and Immunology, Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Liverpool, UK
1 shared publication Brendan Sargent
Liverpool Interdisciplinary Neuroscience Centre, Liverpool, UK
1 shared publication
Latest Publications
- Open Access
- 29 April 2026
- Published by BMJ in Practical Neurology
- Vol. 26 (5) , 426-439
Suspected encephalitis in adults
‘Query encephalitis’ is one of the most common reasons for inpatient neurology referral in the context of an acutely confused patient. Growing evidence suggests that time to treatment is a key determinant of outcome in both infectious and autoimmune encephalitis; hence, these two causes should be considered simultaneously at presentation. However, under-recognition and the existence of several mimics make a rapid diagnosis of encephalitis challenging. Appreciation of clinical syndromes can guide aetiological investigation and consequent treatment. In this article, we discuss clinical phenotypes associated with both infectious and autoimmune encephalitis, as well as a systematic approach to their investigation and up-to-date treatment strategies. We also highlight ongoing areas of research, such as metagenomics and therapeutic trials.
- 29 April 2026
- Published by BMJ in Practical Neurology
- Vol. 26 (5) , 426-439
Open AccessSuspected encephalitis in adults
‘Query encephalitis’ is one of the most common reasons for inpatient neurology referral in the context of an acutely confused patient. Growing evidence suggests that time to treatment is a key determinant of outcome in both infectious and autoimmune encephalitis; hence, these two causes should be considered simultaneously at presentation. However, under-recognition and the existence of several mimics make a rapid diagnosis of encephalitis challenging. Appreciation of clinical syndromes can guide aetiological investigation and consequent treatment. In this article, we discuss clinical phenotypes associated with both infectious and autoimmune encephalitis, as well as a systematic approach to their investigation and up-to-date treatment strategies. We also highlight ongoing areas of research, such as metagenomics and therapeutic trials.
- Open Access
- 30 January 2026
- Published by Springer Nature in Journal of Neurology
- Vol. 273 (2) , 108
Real-world evaluation of an automated EEG spike detection software in a tertiary centre compared to a clinical reference standard
Background: Interictal epileptiform discharges (IEDs) are transient spikes or waves that occur in electroencephalography (EEG) records and can help support the diagnosis and classification of epilepsy. High-throughput machine learning models aim to automate the detection of IEDs. Previous evaluations of machine learning models have reported non-inferiority compared to human experts, but these studies predominantly use small datasets of pre-selected, ‘IED rich’ records, which are not representative of clinical practice. Therefore, this study aims to analyse the accuracy of machine learning models in a large, routine, clinically representative cohort. Methods: All routine EEGs performed in a large regional hospital in England were identified between June 2024 and February 2025. EEG records were run through the commercial machine learning model P15 and automated IED reports generated. The sensitivity, specificity, positive and negative predictive value of P15-detected IEDs were evaluated using the final clinical report as a reference standard. Results: Of 484 EEG records, 53 were reported to contain at least one IED in the final clinical report. At P15’s default sensitivity setting, sensitivity for IED detection was 81.1% (95% CI:77.6–84.6), specificity 59.9% (95% CI: 55.5–64.2), positive predictive value 19.9% (95% CI:16.3–23.5) and negative predictive value 96.3% (95% CI:94.6–98.0). Discussion: This large-scale study of a machine learning model for identification of IEDs in a representative clinical population found a high negative predictive value suggesting that this may be a useful tool to rule out IEDs. However, the low positive predictive value demonstrates the potential for over-calling IEDs in routine EEGs. Future research should evaluate machine learning models alongside clinical feedback before this approach can have sufficient utility in direct clinical care.
- 30 January 2026
- Published by Springer Nature in Journal of Neurology
- Vol. 273 (2) , 108
Open AccessReal-world evaluation of an automated EEG spike detection software in a tertiary centre compared to a clinical reference standard
Background: Interictal epileptiform discharges (IEDs) are transient spikes or waves that occur in electroencephalography (EEG) records and can help support the diagnosis and classification of epilepsy. High-throughput machine learning models aim to automate the detection of IEDs. Previous evaluations of machine learning models have reported non-inferiority compared to human experts, but these studies predominantly use small datasets of pre-selected, ‘IED rich’ records, which are not representative of clinical practice. Therefore, this study aims to analyse the accuracy of machine learning models in a large, routine, clinically representative cohort. Methods: All routine EEGs performed in a large regional hospital in England were identified between June 2024 and February 2025. EEG records were run through the commercial machine learning model P15 and automated IED reports generated. The sensitivity, specificity, positive and negative predictive value of P15-detected IEDs were evaluated using the final clinical report as a reference standard. Results: Of 484 EEG records, 53 were reported to contain at least one IED in the final clinical report. At P15’s default sensitivity setting, sensitivity for IED detection was 81.1% (95% CI:77.6–84.6), specificity 59.9% (95% CI: 55.5–64.2), positive predictive value 19.9% (95% CI:16.3–23.5) and negative predictive value 96.3% (95% CI:94.6–98.0). Discussion: This large-scale study of a machine learning model for identification of IEDs in a representative clinical population found a high negative predictive value suggesting that this may be a useful tool to rule out IEDs. However, the low positive predictive value demonstrates the potential for over-calling IEDs in routine EEGs. Future research should evaluate machine learning models alongside clinical feedback before this approach can have sufficient utility in direct clinical care.