Sahil Kumar
Sahil Kumar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Narinder Kaur
Department of Microbiology, MM Institute of Medical Sciences and Research, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana, India
2 shared publications - Ankur Kaushal
Department of Biosciences and Technology, Maharishi Markandeshwar Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, India
1 shared publication - Bimal Kumar Agrawal
Department of Medicine, MM Institute of Medical Sciences and Research, Maharishi Markandeshwar Deemed to be University, Mullana, Haryana, India
1 shared publication - Harit Kumar
Department of Microbiology, Maharishi Markandeshwar Institute of Medical Sciences and Research, Maharishi Markandeshwar (Deemed to be) University, Mullana, India
1 shared publication - Nandita Sharma
Department of Medical Microbiology, Post Graduate Institute of Medical Education & Research, Chandigarh
1 shared publication - Rohit Kumar1 shared publication
Latest Publications
- 1 June 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (11) , 115501
Optimized and Cost-Effective Portable Electrochemical DNA Sensor for Dual-Gene Detection of Neisseria Gonorrhoeae in Patients Using In-House Printed Electrodes
In this study, a screen-printed electrode modified with gold nanoparticle-stabilized graphene quantum dots and ssDNA probe (SPPE/AuNPs@GQDs/ssDNA) based biosensor compatible with smartphone technology for electrochemical detection of Neisseria gonorrhoeae (NG) via targeting two different genes ( FitA and MsrA ) was developed. The gold stabilized graphene quantum dots (AuNPs@GQDs) were synthesized and characterized using UV–vis spectroscopy, Fourier Transform Infrared Spectroscopy (FTIR), fluorometry, particle analyser, zeta potential and Transmission Electron Microscopy (TEM), confirming their successful synthesis and functionalization. The electrode surface characterization was assured through Scanning Electron Microscopy (SEM), Energy Dispersive X-ray (EDX) and FTIR. The electrochemical response of biosensor was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The FitA and MsrA gene-based DNA sensor exhibited exceptional sensitivity, reaching 16,333.9 (μA/mm 2 )/ng, 140.38(μA/mm 2 )/ng with detection limits of 0.73 fg μl −1 , 100 fg μl −1 respectively via DPV. Selectivity and specificity studies revealed the sensor’s ability to differentiate NG DNA from non-target bacterial DNA and mismatched sequences, confirming its robustness. FitA and MsrA based validation studies using cervical swab samples further confirmed diagnostic potential and enabled cross-verification of enhanced specificity and accuracy. The portable SPPE/AuNPs@GQDs/ssDNA sensor offers a cost-effective, and highly sensitive platform for NG detection, demonstrating potential for point-of-care diagnostics.
- 1 June 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (11) , 115501
Optimized and Cost-Effective Portable Electrochemical DNA Sensor for Dual-Gene Detection of Neisseria Gonorrhoeae in Patients Using In-House Printed Electrodes
In this study, a screen-printed electrode modified with gold nanoparticle-stabilized graphene quantum dots and ssDNA probe (SPPE/AuNPs@GQDs/ssDNA) based biosensor compatible with smartphone technology for electrochemical detection of Neisseria gonorrhoeae (NG) via targeting two different genes ( FitA and MsrA ) was developed. The gold stabilized graphene quantum dots (AuNPs@GQDs) were synthesized and characterized using UV–vis spectroscopy, Fourier Transform Infrared Spectroscopy (FTIR), fluorometry, particle analyser, zeta potential and Transmission Electron Microscopy (TEM), confirming their successful synthesis and functionalization. The electrode surface characterization was assured through Scanning Electron Microscopy (SEM), Energy Dispersive X-ray (EDX) and FTIR. The electrochemical response of biosensor was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The FitA and MsrA gene-based DNA sensor exhibited exceptional sensitivity, reaching 16,333.9 (μA/mm 2 )/ng, 140.38(μA/mm 2 )/ng with detection limits of 0.73 fg μl −1 , 100 fg μl −1 respectively via DPV. Selectivity and specificity studies revealed the sensor’s ability to differentiate NG DNA from non-target bacterial DNA and mismatched sequences, confirming its robustness. FitA and MsrA based validation studies using cervical swab samples further confirmed diagnostic potential and enabled cross-verification of enhanced specificity and accuracy. The portable SPPE/AuNPs@GQDs/ssDNA sensor offers a cost-effective, and highly sensitive platform for NG detection, demonstrating potential for point-of-care diagnostics.
- Open Access
- 30 January 2026
- Published by Journal of Pure and Applied Microbiology in Journal of Pure and Applied Microbiology
- Vol. 20 (1) , 260
Limited Therapeutic Options in blaNDM and blaOXA-48 producing Carbapenem-resistant Klebsiella pneumoniae: Insights from a Cross-sectional Study
Carbapenem-resistant K. pneumoniae (CRKP), listed in the WHO 2024 priority, hydrolyzes β-lactam antibiotics, especially carbapenems, posing a significant challenge. Carbapenems are the last resort antibiotics for severe Gram-negative infections and are associated with increased mortality in ICUs and IPDs. This cross-sectional study at a tertiary hospital (April 2023-December 2024) included 375 multidrug-resistant (MDR) K. pneumoniae isolates with ertapenem MIC ≥8 µg/mL. Carbapenemase genes were detected via conventional PCR. Bivariate analysis examined clinical correlations, while MIC50/90 assessed resistance. The most common carbapenemase genes were blaNDM (48.26%) and blaOXA-48 (37.86%), followed by blaKPC (13.6%). Co-occurrence of genes was also reported. Twelve of seventeen clinical variables were significantly associated with gene presence (p < 0.05). Ertapenem, imipenem, and meropenem had MIC50/90 ≥8 µg/mL, indicating high resistance. Tigecycline showed better sensitivity, with MIC50/90 of 0.5/2 µg/mL (blaNDM) and 2/2 µg/mL (blaOXA-48). Fosfomycin MIC90 in blaOXA-48 isolates ranged up to 256 µg/mL. The study highlights high blaNDM and blaOXA-48 prevalence, their clinical associations, and limited therapeutic options. Tigecycline remains most effective in vitro, but pharmacokinetic concerns exist. These findings emphasize the need for antimicrobial stewardship and molecular surveillance.
- 30 January 2026
- Published by Journal of Pure and Applied Microbiology in Journal of Pure and Applied Microbiology
- Vol. 20 (1) , 260
Open AccessLimited Therapeutic Options in blaNDM and blaOXA-48 producing Carbapenem-resistant Klebsiella pneumoniae: Insights from a Cross-sectional Study
Carbapenem-resistant K. pneumoniae (CRKP), listed in the WHO 2024 priority, hydrolyzes β-lactam antibiotics, especially carbapenems, posing a significant challenge. Carbapenems are the last resort antibiotics for severe Gram-negative infections and are associated with increased mortality in ICUs and IPDs. This cross-sectional study at a tertiary hospital (April 2023-December 2024) included 375 multidrug-resistant (MDR) K. pneumoniae isolates with ertapenem MIC ≥8 µg/mL. Carbapenemase genes were detected via conventional PCR. Bivariate analysis examined clinical correlations, while MIC50/90 assessed resistance. The most common carbapenemase genes were blaNDM (48.26%) and blaOXA-48 (37.86%), followed by blaKPC (13.6%). Co-occurrence of genes was also reported. Twelve of seventeen clinical variables were significantly associated with gene presence (p < 0.05). Ertapenem, imipenem, and meropenem had MIC50/90 ≥8 µg/mL, indicating high resistance. Tigecycline showed better sensitivity, with MIC50/90 of 0.5/2 µg/mL (blaNDM) and 2/2 µg/mL (blaOXA-48). Fosfomycin MIC90 in blaOXA-48 isolates ranged up to 256 µg/mL. The study highlights high blaNDM and blaOXA-48 prevalence, their clinical associations, and limited therapeutic options. Tigecycline remains most effective in vitro, but pharmacokinetic concerns exist. These findings emphasize the need for antimicrobial stewardship and molecular surveillance.