RWRunsheng Wang

Runsheng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Runsheng Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Dawn M. Nilsen

    Department of Rehabilitation and Regenerative Medicine Columbia University Irving Medical Center 10032 New York NY USA

    1 shared publication
  • Joel Stein

    Department of Rehabilitation and Regenerative Medicine Columbia University Irving Medical Center 10032 New York NY USA

    1 shared publication
  • Katelyn Lee

    Department of Mechanical Engineering Columbia University

    1 shared publication
  • Lauren Winterbottom

    Department of Rehabilitation and Regenerative Medicine Columbia University Irving Medical Center 10032 New York NY USA

    1 shared publication
  • Matei Ciocarlie

    Department of Mechanical Engineering, Columbia University, New York, NY, USA

    1 shared publication
  • Xinyue Zhu

    Department of Computer Science Columbia University

    1 shared publication

Latest Publications

  • Open Access

    ReactEMG Stroke: Healthy-to-Stroke Few-shot Adaptation for sEMG-Based Intent Detection

    by Runsheng Wang, Katelyn Lee, Xinyue Zhu, Lauren Winterbottom, Dawn M. Nilsen, Joel Stein, Matei Ciocarlie

    Surface electromyography (sEMG) is a promising control signal for assist-as-needed hand rehabilitation after stroke, but detecting intent from paretic muscles often requires lengthy, subject-specific calibration and remains brittle to variability. We propose a healthy-to-stroke adaptation pipeline that initializes an intent detector from a model pretrained on large-scale able-bodied sEMG, then fine-tunes it for each stroke participant using only a small amount of subject-specific data. Using a newly collected dataset from three individuals with chronic stroke, we compare adaptation strategies (head-only tuning, parameter-efficient LoRA adapters, and full end-to-end fine-tuning) and evaluate on held-out test sets that include realistic distribution shifts such as within-session drift, posture changes, and armband repositioning. Across conditions, healthy-pretrained adaptation consistently improves stroke intent detection relative to both zero-shot transfer and stroke-only training under the same data budget; the best adaptation methods improve average transition accuracy from 0.42 to 0.61 and raw accuracy from 0.69 to 0.78. These results suggest that transferring a reusable healthy-domain EMG representation can reduce calibration burden while improving robustness for real-time post-stroke intent detection.