RRRohit Rohit

Rohit Rohit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rohit Rohit has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Riya Choudhary

    Department of Physics, Indian Institute of Technology Roorkee, Roorkee, India

    1 shared publication
  • Sachin Sachin

    Department of Physics and the Centre for Photonics and Quantum Communication Technology, Indian Institute of Technology Roorkee, Roorkee, India

    1 shared publication

Latest Publications

  • Poriferous Flexible Plasmonic Nanocolumns-Based Micro-Spot Sensing of Mercury Ion via Enhanced Fluorescence

    by Riya Riya, Rohit Rohit, Sachin Sachin

    In this study, a plasmonic sensor was developed utilizing templating-assisted fabrication of poriferous flexible silver (Ag) nanocolumns (NCOLs) embedded in polydimethylsiloxane (PDMS) for the detection of mercury ions (Hg2+) in dual modes of operation (dry and wet modes). The detection mechanism relied on the fluorescence signal from rhodamine-6G (R6G) molecules over Ag-NCOLs in the presence of Hg2+ ion and cystamine (Cys). In dry mode, the fluorescence signal gradually increased as the concentration of Hg2+ ion increased while the concentration of Cys was fixed, and vice versa. In wet mode, the fluorescence signal experienced gradual quenching as the concentration of Hg2+ ions was increased for a fixed concentration of Cys. However, with an increase in the concentration of Cys with fixed concentration of Hg2+ ion, the fluorescence signal increased in the wet mode. Fluorescence lifetime spectroscopy (FLS), Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS) measurements were performed as control experiments to understand the increase and quenching of fluorescence mechanism distinctly. The sensor effectively detected this variation in concentration of Hg2+ as a function of fluorescence intensity. Remarkably, the limit of detection (LoD) for Hg2+ ion was estimated to be 10 fM and 5 fM, spanning a dynamic range from 0.001 to 100 pM in dry and wet modes, respectively. The fabricated sensor demonstrates reusability, exceptional selectivity for Hg2+ ion, and rapid response time. This innovative approach promises sensitive, selective and efficient detection of Hg2+ ion in various food safety applications, environmental, and biological samples.