Catherine T. Nordgård
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Catherine T. Nordgård has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Berit Løkensgard Strand
Department of Biotechnology and Food Science, NTNU, Norway
2 shared publications - Joachim Sebastian Kjesbu
Norwegian Biopolymer Laboratory (NOBIPOL), Department of Biotechnology and Food Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications - Amalie J. H. Mathisen
Norwegian University of Science and Technology image/svg+xml
1 shared publication - Aman S. Chahal
Department of Biotechnology and Food Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway; Department of Biotechnology and Nanomedicine, SINTEF Industry, Trondheim, Norway; Department of Clinical and Molecular Medicine, NTNU, Trondheim, Norway
1 shared publication - Daria Zaytseva-Zotova
Polymers for Biology Laboratory, Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, 117997, Miklukho-Maklaya 16/10, Moscow, Russia
1 shared publication - Finn Lillelund Aachmann
Department of Biotechnology and Food Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 26 August 2026
- Published by Stavanger University Library in Annual Transactions of the Nordic Rheology Society
- Vol. 34, 61-65
In Situ Rheology of the Biofilm from a Nitrifying Bioreactor Relevant for RAS – a Proof of Principle Study
Nitrifying bioreactors are a vital component of recirculating aquaculture systems (RAS) to maintain the required water quality. Bioreactors contain suspended plastic carriers on which nitrifying microorganisms grow. Understanding the rheology of biofilms that form on these carriers can provide useful information that can be correlated with other analyses to monitor the development and stability of the microbial communities, both over the lifetime of the bioreactor and in response to environmental changes, such as the salinity changes typical of salmonid aquaculture. The standard carriers have an open patterned geometry for biofilm formation and good fluid flow through but is not convenient for in situ rheological measurements. In this study, we included carriers in the same material (HDPE) and with the same external dimensions but with a 20mm diameter flat surface area suitable for placement within the rheometer. The carriers were placed in stainless steel “tea-ball” cages in two lab-scale bioreactors with different configurations for five weeks and then retrieved. After securing the carrier within the rheometer (Kinexus Ultra+ with a 20mm roughened parallel plate upper geometry) the upper plate was lowered to a normal force of 0.05N. Oscillatory measurements (frequency sweep and amplitude sweep) and creep compliance measurements confirmed the biofilm on the carrier surface as a solid dominant viscoelastic solid at low strain. This is comparable with the reported behaviour of microbial biofilms.
- 26 August 2026
- Published by Stavanger University Library in Annual Transactions of the Nordic Rheology Society
- Vol. 34, 61-65
Open AccessIn Situ Rheology of the Biofilm from a Nitrifying Bioreactor Relevant for RAS – a Proof of Principle Study
Nitrifying bioreactors are a vital component of recirculating aquaculture systems (RAS) to maintain the required water quality. Bioreactors contain suspended plastic carriers on which nitrifying microorganisms grow. Understanding the rheology of biofilms that form on these carriers can provide useful information that can be correlated with other analyses to monitor the development and stability of the microbial communities, both over the lifetime of the bioreactor and in response to environmental changes, such as the salinity changes typical of salmonid aquaculture. The standard carriers have an open patterned geometry for biofilm formation and good fluid flow through but is not convenient for in situ rheological measurements. In this study, we included carriers in the same material (HDPE) and with the same external dimensions but with a 20mm diameter flat surface area suitable for placement within the rheometer. The carriers were placed in stainless steel “tea-ball” cages in two lab-scale bioreactors with different configurations for five weeks and then retrieved. After securing the carrier within the rheometer (Kinexus Ultra+ with a 20mm roughened parallel plate upper geometry) the upper plate was lowered to a normal force of 0.05N. Oscillatory measurements (frequency sweep and amplitude sweep) and creep compliance measurements confirmed the biofilm on the carrier surface as a solid dominant viscoelastic solid at low strain. This is comparable with the reported behaviour of microbial biofilms.
- 24 January 2026
- Published by Elsevier in Carbohydrate Polymers
- Vol. 378, 125007
Physical-mechanical properties of fucoidan-alginate composite hydrogels
- 24 January 2026
- Published by Elsevier in Carbohydrate Polymers
- Vol. 378, 125007
Physical-mechanical properties of fucoidan-alginate composite hydrogels
- Open Access
- 10 January 2026
- Published by Elsevier in Carbohydrate Polymers
- Vol. 379, 124913
RGD-Alginate beads as scaffolds for culturing primary human dermal and pulmonary fibroblasts
- 10 January 2026
- Published by Elsevier in Carbohydrate Polymers
- Vol. 379, 124913
Open AccessRGD-Alginate beads as scaffolds for culturing primary human dermal and pulmonary fibroblasts