Shehzad Alamgir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shehzad Alamgir has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Arif Mehdi
Sungkyunkwan University
1 shared publication - Muhammad Ali
Department of Semiconductor Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
1 shared publication - S. Jarjees Ul Hassan
Centre for Energy Technologies, Department of Business Development and Technology, Aarhus University, Birk Centerpark 15, 7400 Herning, Denmark
1 shared publication - Zeeshan Haider
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 2 February 2026
- Published by MDPI AG in Electricity
- Vol. 7 (1) , 11
Analysis of Grounding Schemes and Machine Learning-Based Fault Detection in Hybrid AC/DC Distribution System
The increasing integration of hybrid AC/DC networks in modern power systems introduces new challenges in fault detection and grounding scheme design, necessitating advanced techniques for stable and reliable operation. This paper investigates fault detection and grounding schemes in hybrid AC/DC networks using a machine learning (ML) approach to enhance accuracy, speed, and adaptability. Traditional methods often struggle with the dynamic and complex nature of hybrid systems, leading to delayed or incorrect fault identification. To address this, we propose a data-driven ML framework that leverages features such as voltage, current, and frequency characteristics for real-time detection and classification of faults. Additionally, the effectiveness of various grounding schemes is analyzed under different fault conditions to ensure system stability and safety. Simulation results on a hybrid AC/DC test network demonstrate the superior performance of the proposed ML-based fault detection method compared to conventional techniques, achieving high precision, recall, and robustness against noise and varying operating conditions. The findings highlight the potential of ML in improving fault management and grounding strategy optimization for future hybrid power grids.
- 2 February 2026
- Published by MDPI AG in Electricity
- Vol. 7 (1) , 11
Open AccessAnalysis of Grounding Schemes and Machine Learning-Based Fault Detection in Hybrid AC/DC Distribution System
The increasing integration of hybrid AC/DC networks in modern power systems introduces new challenges in fault detection and grounding scheme design, necessitating advanced techniques for stable and reliable operation. This paper investigates fault detection and grounding schemes in hybrid AC/DC networks using a machine learning (ML) approach to enhance accuracy, speed, and adaptability. Traditional methods often struggle with the dynamic and complex nature of hybrid systems, leading to delayed or incorrect fault identification. To address this, we propose a data-driven ML framework that leverages features such as voltage, current, and frequency characteristics for real-time detection and classification of faults. Additionally, the effectiveness of various grounding schemes is analyzed under different fault conditions to ensure system stability and safety. Simulation results on a hybrid AC/DC test network demonstrate the superior performance of the proposed ML-based fault detection method compared to conventional techniques, achieving high precision, recall, and robustness against noise and varying operating conditions. The findings highlight the potential of ML in improving fault management and grounding strategy optimization for future hybrid power grids.