Shiwei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiwei Wu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Fu
School of Automation, Qingdao University, Qingdao 266071, China
1 shared publication - Dejun Pan
School of Automation, Qingdao University, Qingdao 266071, China
1 shared publication - Guanguan Zhang
School of Control Science and Engineering, Shandong University, Jinan 250061, China
1 shared publication - Le Chang
College of Electric Power Engineering, Shanghai University of Electric Power, Shanghai, China
1 shared publication - Xiaoling Wang
School of Automation, Qingdao University, Qingdao 266071, China
1 shared publication
Latest Publications
- Open Access
Finite-Time Backstepping Control for Stand-Alone Three-Phase Voltage-Source Inverters Based on Disturbance Observer
For the three-phase voltage-source inverters (VSIs), load disturbances and parameter uncertainties degrade the quality of output voltages, potentially leading to system instability. To improve steady-state precision and disturbance rejection, this paper suggests a finite-time backstepping control (FTBC) strategy that incorporates a fixed-time sliding mode disturbance observer (FTSMDO). Firstly, this paper establishes a new dynamic model of the three-phase VSI considering load disturbances, parameter uncertainty and cross-coupling effect. Subsequently, a fixed-time disturbance observer is then developed to precisely estimate the uncertain disturbances, with its convergence time not reliant on the system’s initial conditions. Concurrently, a finite-time differentiator is developed to achieve the desired signals, thereby sidestepping the “explosion of complexity” problem. A finite-time controller is constructed to obtain stable three-phase output voltages. Theoretical and test analysis demonstrate the proposed method is effective. Compared with the PI control, the proposed strategy improves dynamic performance and enhances disturbance-rejection capability under time-varying load disturbances.
Open AccessFinite-Time Backstepping Control for Stand-Alone Three-Phase Voltage-Source Inverters Based on Disturbance Observer
For the three-phase voltage-source inverters (VSIs), load disturbances and parameter uncertainties degrade the quality of output voltages, potentially leading to system instability. To improve steady-state precision and disturbance rejection, this paper suggests a finite-time backstepping control (FTBC) strategy that incorporates a fixed-time sliding mode disturbance observer (FTSMDO). Firstly, this paper establishes a new dynamic model of the three-phase VSI considering load disturbances, parameter uncertainty and cross-coupling effect. Subsequently, a fixed-time disturbance observer is then developed to precisely estimate the uncertain disturbances, with its convergence time not reliant on the system’s initial conditions. Concurrently, a finite-time differentiator is developed to achieve the desired signals, thereby sidestepping the “explosion of complexity” problem. A finite-time controller is constructed to obtain stable three-phase output voltages. Theoretical and test analysis demonstrate the proposed method is effective. Compared with the PI control, the proposed strategy improves dynamic performance and enhances disturbance-rejection capability under time-varying load disturbances.