Xiaochen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaochen Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Nan Wang
Songshan Lake Materials Laboratory, Dongguan 523808, China
1 shared publication - Pengfei Yang
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310014, China
1 shared publication - Wei Wang
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310014, China
1 shared publication - Wenjun Shu
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310014, China
1 shared publication - Xindong Liang
University of Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Zhen Yang
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310014, China
1 shared publication
Latest Publications
- Open Access
- 3 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1525
FPGA-Based Real-Time Measurement System for Single-Shot Carrier-Envelope Phase in High-Repetition-Rate Laser Amplification Systems
To address the issue of low closed-loop feedback bandwidth caused by the long latency of Carrier-Envelope Phase (CEP) measurement systems for amplified femtosecond laser pulses, and to meet the requirements for real-time single-shot measurement in 10 kHz repetition rate systems, this paper proposes a microsecond-level low-latency CEP measurement technique based on a Field-Programmable Gate Array (FPGA). To tackle the problem of non-uniform spectral sampling resulting from nonlinear wavelength-frequency mapping, the system implements a real-time linear interpolation algorithm for the interference spectrum. This approach effectively suppresses computational spurious peaks introduced by non-uniform sampling and significantly reduces measurement errors. Adopting a fully pipelined parallel processing architecture, the system achieves a CEP processing latency of approximately 89 μs, representing an improvement of 2–3 orders of magnitude compared to traditional Central Processing Unit (CPU)-based solutions. Hardware-in-the-loop testing, conducted by injecting a known sinusoidal phase modulation into the interference spectrum of a 10 kHz laser amplification system, demonstrates that the computational error of the proposed algorithm is less than 30 mrad. This work paves the way for achieving single-shot CEP feedback locking in high-repetition-rate laser amplification systems.
- 3 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (3) , 1525
Open AccessFPGA-Based Real-Time Measurement System for Single-Shot Carrier-Envelope Phase in High-Repetition-Rate Laser Amplification Systems
To address the issue of low closed-loop feedback bandwidth caused by the long latency of Carrier-Envelope Phase (CEP) measurement systems for amplified femtosecond laser pulses, and to meet the requirements for real-time single-shot measurement in 10 kHz repetition rate systems, this paper proposes a microsecond-level low-latency CEP measurement technique based on a Field-Programmable Gate Array (FPGA). To tackle the problem of non-uniform spectral sampling resulting from nonlinear wavelength-frequency mapping, the system implements a real-time linear interpolation algorithm for the interference spectrum. This approach effectively suppresses computational spurious peaks introduced by non-uniform sampling and significantly reduces measurement errors. Adopting a fully pipelined parallel processing architecture, the system achieves a CEP processing latency of approximately 89 μs, representing an improvement of 2–3 orders of magnitude compared to traditional Central Processing Unit (CPU)-based solutions. Hardware-in-the-loop testing, conducted by injecting a known sinusoidal phase modulation into the interference spectrum of a 10 kHz laser amplification system, demonstrates that the computational error of the proposed algorithm is less than 30 mrad. This work paves the way for achieving single-shot CEP feedback locking in high-repetition-rate laser amplification systems.