  • Open Access

    Characterisation and model validation of actively modulated thermal transmittance in a closed-loop bio-based polyurethane active insulation system

    by Ingrid Demanega, Francesco Isaia, Giordano Miori, Miren Juaristi

    Closed-loop active insulation systems can modulate heat transfer through opaque building envelopes by coupling insulation with controlled internal airflow. By responding to changing environmental conditions, these systems can exploit favourable thermal conditions to support reduced heating and cooling demand in high-performance and net-zero buildings. However, their development is hindered by the lack of systematic methodologies combining full-scale experimental characterisation with validated thermo-fluid modelling. This paper presents an integrated experimental and numerical methodology for the development and validation of a closed-loop active insulation system based on bio-based polyurethane (BioPUR). The investigated component consists of a full-scale insulation panel with embedded air channels and axial fans, designed to switch between insulating and heat-exchanging states. Parametric numerical analysis supported prototype design, followed by experimental characterization in a guarded hot-box facility under controlled steady-state boundary conditions representative of U-value and cooling-demand night scenarios. A three-dimensional conjugate heat-transfer and fluid-flow model was developed in COMSOL Multiphysics and validated against measured surface temperatures and heat fluxes using uncertainty-normalised validation metrics. The system achieved significant thermal adaptation, with measured overall U-values rising from 0.17 to 0.58 Wm-2K-1 (adaptation ratio of 3.4) in the most effective fan configuration. The model accurately reproduces passive and single-fan operation, providing a reliable basis for predicting component behaviour. The validated framework supports design optimisation and future building-scale integration of adaptive envelope technologies, enabling exploration of alternative geometries, airflow configurations, and material choices towards responsive, high-performance building envelopes supporting the transition to net-zero carbon buildings.

  • Measuring Box for On-site Thermal Assessment of Windows: Presentation of a Movable Prototype, Applied Calculation and Application

    by Simone Panico, Dagmar Exner, Marco Larcher, Alexandra Troi, Giordano Miori, David Cennamo, Daniel Herrera-Avellanosa