Huong-Tra Ngo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huong-Tra Ngo has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Andrew R. Jamieson
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, USA
2 shared publications - David Hein
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, USA
2 shared publications - Michael Holcomb
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, USA
2 shared publications - Philip Jarrett
Department of Emergency Medicine, The University of Texas Southwestern Medical Center, Dallas, USA
2 shared publications - Thomas O. Dalton
Department of Internal Medicine, UT Southwestern Medical Center, Dallas, USA
2 shared publications Ameer Hamza Shakur
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, USA
1 shared publication
Latest Publications
- Open Access
- 7 October 2026
- Published by Springer Nature in npj Digital Medicine
Prospective deployment of multimodal AI grading for medical student OSCEs
- 7 October 2026
- Published by Springer Nature in npj Digital Medicine
Open AccessProspective deployment of multimodal AI grading for medical student OSCEs
- Open Access
- 21 August 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (10)
Integrins and tetraspanins mediate CD36-actin coupling and regulate CD36 organization and signaling
Submembrane cortical actin (CA) plays a large role in regulating the dynamic organization of cell surface receptors, which in turn regulates receptor signaling. Many receptors have short intracellular domains and no known link to actin. Here, we identified the β1-integrin subunit and several tetraspanins (CD9, CD81, and CD151) as part of the hitherto unknown molecular link between the receptor CD36 and CA. Our data indicate that CD36 in vascular endothelial cells interacts with these proteins, with stronger interactions near the cell edge. Compromising these interactions via the point mutation G12V in the N-terminal transmembrane domain of CD36 alters the dynamic organization of CD36 on the cell surface and weakens its coupling to CA dynamics. Moreover, it abolishes thrombospondin-1–induced CD36 signaling through the Src family kinase Fyn. Given their many interactions with transmembrane proteins, tetraspanins and integrins may provide a ubiquitous mechanism for plasma membrane–CA coupling.
- 21 August 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (10)
Open AccessIntegrins and tetraspanins mediate CD36-actin coupling and regulate CD36 organization and signaling
Submembrane cortical actin (CA) plays a large role in regulating the dynamic organization of cell surface receptors, which in turn regulates receptor signaling. Many receptors have short intracellular domains and no known link to actin. Here, we identified the β1-integrin subunit and several tetraspanins (CD9, CD81, and CD151) as part of the hitherto unknown molecular link between the receptor CD36 and CA. Our data indicate that CD36 in vascular endothelial cells interacts with these proteins, with stronger interactions near the cell edge. Compromising these interactions via the point mutation G12V in the N-terminal transmembrane domain of CD36 alters the dynamic organization of CD36 on the cell surface and weakens its coupling to CA dynamics. Moreover, it abolishes thrombospondin-1–induced CD36 signaling through the Src family kinase Fyn. Given their many interactions with transmembrane proteins, tetraspanins and integrins may provide a ubiquitous mechanism for plasma membrane–CA coupling.
- Open Access
Automated Assessment of OSCE Physical Exams using Multimodal AI
Background: The assessment of physical examination skills in medical education is resource-intensive and prone to inter-rater variability. While artificial intelligence (AI) has successfully automated the grading of clinical notes and transcripts, evaluating the physical techniques themselves—what students do rather than what they say—remains an unsolved challenge. We evaluated whether a multimodal AI system could assess physical examination skills with expert-level reliability. Methods: In this retrospective ablation study, we analyzed 300 video-recorded encounters from six Objective Structured Clinical Examination (OSCE) stations (cardiovascular, respiratory, gastrointestinal, musculoskeletal, and neurological). We compared the performance of a multimodal AI model (Gemini 2.5 Pro) across single- and multi-camera configurations and isolated input modalities (video, audio-only, transcript-only, visual-only) against standard human grading. The primary outcome was agreement with a physician-adjudicated ground-truth reference standard, measured by quadratic weighted Cohen’s kappa (κ). Results: The AI system using a synchronized 3-camera native video configuration achieved significantly higher reliability (κ = 0.830; 95% CI, 0.773–0.880) than the standard human evaluators (κ = 0.732; 95% CI, 0.687–0.776). Performance followed a strict hierarchy: native video > audio-only > transcript-only > visual-only. Notably, visual-only models failed (κ ≈ 0.20) despite high detection accuracy, revealing a “visual paradox” where models could identify when an action occurred but not how well it was performed without audio cues. Conclusions: A properly configured multimodal AI system can grade physical examination skills with reliability exceeding that of trained human evaluators. Success requires native processing of synchronized audio-visual streams; transcript-based or visual-only approaches are insufficient for high-stakes assessment. These findings suggest that AI can provide scalable, objective, and valid assessment of clinical skills, overcoming the limitations of traditional human grading. Abstract Figure:
Open AccessAutomated Assessment of OSCE Physical Exams using Multimodal AI
Background: The assessment of physical examination skills in medical education is resource-intensive and prone to inter-rater variability. While artificial intelligence (AI) has successfully automated the grading of clinical notes and transcripts, evaluating the physical techniques themselves—what students do rather than what they say—remains an unsolved challenge. We evaluated whether a multimodal AI system could assess physical examination skills with expert-level reliability. Methods: In this retrospective ablation study, we analyzed 300 video-recorded encounters from six Objective Structured Clinical Examination (OSCE) stations (cardiovascular, respiratory, gastrointestinal, musculoskeletal, and neurological). We compared the performance of a multimodal AI model (Gemini 2.5 Pro) across single- and multi-camera configurations and isolated input modalities (video, audio-only, transcript-only, visual-only) against standard human grading. The primary outcome was agreement with a physician-adjudicated ground-truth reference standard, measured by quadratic weighted Cohen’s kappa (κ). Results: The AI system using a synchronized 3-camera native video configuration achieved significantly higher reliability (κ = 0.830; 95% CI, 0.773–0.880) than the standard human evaluators (κ = 0.732; 95% CI, 0.687–0.776). Performance followed a strict hierarchy: native video > audio-only > transcript-only > visual-only. Notably, visual-only models failed (κ ≈ 0.20) despite high detection accuracy, revealing a “visual paradox” where models could identify when an action occurred but not how well it was performed without audio cues. Conclusions: A properly configured multimodal AI system can grade physical examination skills with reliability exceeding that of trained human evaluators. Success requires native processing of synchronized audio-visual streams; transcript-based or visual-only approaches are insufficient for high-stakes assessment. These findings suggest that AI can provide scalable, objective, and valid assessment of clinical skills, overcoming the limitations of traditional human grading. Abstract Figure: