Vincent Gemar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vincent Gemar has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Abdallah Alashqar
Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
3 shared publications - Andreas Rowald
Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
3 shared publications - Esra Neufeld
Foundation for Research on Information Technologies in Society (IT’IS), Zurich, Switzerland
2 shared publications - Fabien B. Wagner
Univ. Bordeaux, CNRS, IMN, UMR 5293, F-33000 Bordeaux, France
2 shared publications - Ismael Seáñez
Washington University in St. Louis
2 shared publications - Zhaoshun Hu
Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
2 shared publications
Latest Publications
- Open Access
- 8 September 2026
- Published by Springer Nature in Communications Biology
A generalized activating function for rapid and accurate neural response prediction in spinal cord stimulation
We present the Generalized Activating Function (GAF), a biophysics-grounded framework that accelerates neural activation predictions by up to three orders of magnitude relative to NEURON simulations of multi-compartment cable models while maintaining high predictive accuracy ( R 2 = 0.99). By overcoming computational bottlenecks in patient-specific modeling, the GAF enables practical translation of computational optimization into neuromodulation therapies such as spinal cord stimulation (SCS). We verify the GAF’s physiological validity by demonstrating near-perfect agreement with multi-compartment simulations for activation thresholds and spike initiation location/timing across multiple pulse widths in an anatomically realistic spine model. We validate clinical relevance by reproducing a published SCS optimization study for lower-limb motor recovery, matching NEURON-based prediction accuracy while reducing computation time from hours to seconds. Finally, we exploit the GAF’s speed to explore previously intractable parameter spaces: Pareto optimization over pulse waveforms uncovers solutions with approximately seven-fold increased energy efficiency at matched activation, while optimization of multielectrode stimulation (16 currents) increases the functional selectivity index for right hip flexion from 52% (clinical benchmark) to 82% in under one minute. By eliminating computational bottlenecks and enabling gains in efficiency and selectivity, the GAF transforms model-driven optimization into a clinically viable tool for patient-specific neuromodulation.
- 8 September 2026
- Published by Springer Nature in Communications Biology
Open AccessA generalized activating function for rapid and accurate neural response prediction in spinal cord stimulation
We present the Generalized Activating Function (GAF), a biophysics-grounded framework that accelerates neural activation predictions by up to three orders of magnitude relative to NEURON simulations of multi-compartment cable models while maintaining high predictive accuracy ( R 2 = 0.99). By overcoming computational bottlenecks in patient-specific modeling, the GAF enables practical translation of computational optimization into neuromodulation therapies such as spinal cord stimulation (SCS). We verify the GAF’s physiological validity by demonstrating near-perfect agreement with multi-compartment simulations for activation thresholds and spike initiation location/timing across multiple pulse widths in an anatomically realistic spine model. We validate clinical relevance by reproducing a published SCS optimization study for lower-limb motor recovery, matching NEURON-based prediction accuracy while reducing computation time from hours to seconds. Finally, we exploit the GAF’s speed to explore previously intractable parameter spaces: Pareto optimization over pulse waveforms uncovers solutions with approximately seven-fold increased energy efficiency at matched activation, while optimization of multielectrode stimulation (16 currents) increases the functional selectivity index for right hip flexion from 52% (clinical benchmark) to 82% in under one minute. By eliminating computational bottlenecks and enabling gains in efficiency and selectivity, the GAF transforms model-driven optimization into a clinically viable tool for patient-specific neuromodulation.
- Open Access
- 4 March 2026
- Published by Springer Nature in Research Square
Virtual prototyping of non-invasive spinal cord electrical stimulation targeting upper limb motor function
Transcutaneous spinal cord stimulation (tSCS) applied over the cervical or lumbar spinal cord facilitates motor function after paralysis. However, emerging electrophysiological evidence indicates mechanistic differences between cervical and lumbar tSCS and across different cervical tSCS paradigms. To clarify these discrepancies, we developed and validated a multi-scale, whole-body computational model of tSCS-induced volume conduction, axonal recruitment, and synaptic transmission. Across 24 cervical and four lumbar tSCS paradigms, simulations showed that somatosensory afferents consistently exhibit lower stimulation thresholds than motor efferents. In turn, region-specific synaptic transmission differences may explain electrophysiological discrepancies between cervical and lumbar tSCS. Across cervical tSCS paradigms, substantial volume conduction and axonal recruitment differences were observed that explain electrophysiological discrepancies. Specifically, clinically-prevalent paradigms, including those with anodes placed over the clavicles or iliac crests, engaged peripheral nerves in addition to spinal roots. This effect was amplified by multiphasic waveforms, which introduced recruitment sites near the anodes. By integrating simulations with electrophysiological recordings in 14 able-bodied individuals, we investigated previously unexplored cervical tSCS paradigms on their capacity to recruit somatosensory afferents relative to motor threshold.
- 4 March 2026
- Published by Springer Nature in Research Square
Open AccessVirtual prototyping of non-invasive spinal cord electrical stimulation targeting upper limb motor function
Transcutaneous spinal cord stimulation (tSCS) applied over the cervical or lumbar spinal cord facilitates motor function after paralysis. However, emerging electrophysiological evidence indicates mechanistic differences between cervical and lumbar tSCS and across different cervical tSCS paradigms. To clarify these discrepancies, we developed and validated a multi-scale, whole-body computational model of tSCS-induced volume conduction, axonal recruitment, and synaptic transmission. Across 24 cervical and four lumbar tSCS paradigms, simulations showed that somatosensory afferents consistently exhibit lower stimulation thresholds than motor efferents. In turn, region-specific synaptic transmission differences may explain electrophysiological discrepancies between cervical and lumbar tSCS. Across cervical tSCS paradigms, substantial volume conduction and axonal recruitment differences were observed that explain electrophysiological discrepancies. Specifically, clinically-prevalent paradigms, including those with anodes placed over the clavicles or iliac crests, engaged peripheral nerves in addition to spinal roots. This effect was amplified by multiphasic waveforms, which introduced recruitment sites near the anodes. By integrating simulations with electrophysiological recordings in 14 able-bodied individuals, we investigated previously unexplored cervical tSCS paradigms on their capacity to recruit somatosensory afferents relative to motor threshold.
- Open Access
Virtual prototyping of non-invasive spinal cord electrical stimulation targeting upper limb motor function
Transcutaneous spinal cord stimulation (tSCS) applied over the cervical or lumbar spinal cord facilitates motor function after paralysis. However, emerging electrophysiological evidence indicates mechanistic differences between cervical and lumbar tSCS and across different cervical tSCS paradigms. To clarify these discrepancies, we developed and validated a multi-scale, whole-body computational model of tSCS-induced volume conduction, axonal recruitment, and synaptic transmission. Across 24 cervical and four lumbar tSCS paradigms, simulations showed that somatosensory afferents consistently exhibit lower stimulation thresholds than motor efferents. In turn, region-specific synaptic transmission differences may explain electrophysiological discrepancies between cervical and lumbar tSCS. Across cervical tSCS paradigms, substantial volume conduction and axonal recruitment differences were observed that explain electrophysiological discrepancies. Specifically, clinically-prevalent paradigms, including those with anodes placed over the clavicles or iliac crests, engaged peripheral nerves in addition to spinal roots. This effect was amplified by multiphasic waveforms, which introduced recruitment sites near the anodes. By integrating simulations with electrophysiological recordings in 14 able-bodied individuals, we investigated previously unexplored cervical tSCS paradigms on their capacity to recruit somatosensory afferents relative to motor threshold.
Open AccessVirtual prototyping of non-invasive spinal cord electrical stimulation targeting upper limb motor function
Transcutaneous spinal cord stimulation (tSCS) applied over the cervical or lumbar spinal cord facilitates motor function after paralysis. However, emerging electrophysiological evidence indicates mechanistic differences between cervical and lumbar tSCS and across different cervical tSCS paradigms. To clarify these discrepancies, we developed and validated a multi-scale, whole-body computational model of tSCS-induced volume conduction, axonal recruitment, and synaptic transmission. Across 24 cervical and four lumbar tSCS paradigms, simulations showed that somatosensory afferents consistently exhibit lower stimulation thresholds than motor efferents. In turn, region-specific synaptic transmission differences may explain electrophysiological discrepancies between cervical and lumbar tSCS. Across cervical tSCS paradigms, substantial volume conduction and axonal recruitment differences were observed that explain electrophysiological discrepancies. Specifically, clinically-prevalent paradigms, including those with anodes placed over the clavicles or iliac crests, engaged peripheral nerves in addition to spinal roots. This effect was amplified by multiphasic waveforms, which introduced recruitment sites near the anodes. By integrating simulations with electrophysiological recordings in 14 able-bodied individuals, we investigated previously unexplored cervical tSCS paradigms on their capacity to recruit somatosensory afferents relative to motor threshold.