XQXinmiao Qu

Xinmiao Qu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinmiao Qu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Hanfu Shi

    Academy of Macroeconomic Research National Development and Reform Commission of People’s Republic of China, Beijing 100038, China

    1 shared publication
  • Haoran Zhang

    School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China

    1 shared publication
  • Hongyu Yang

    Key Laboratory of Big Data-Based Precision Medicine of Ministry of Industry and Information Technology, School of Engineering Medicine, Beihang University, Beijing 100191, China

    1 shared publication
  • Hui Lin

    Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310018, China

    1 shared publication
  • Ke Li

    Breast Center, Peking University People’s Hospital, Peking University, Beijing 100044, China

    1 shared publication
  • Shu Wang

    Breast Center, Peking University People’s Hospital, Beijing 100044, China

    1 shared publication

Latest Publications

  • Open Access

    Harmonic Ratio Analysis in Magnetic Particle Imaging Enables Differentiation of Malignant and Benign Human Breast Tissues: A Feasibility Study

    by Hongyu Yang, Haoran Zhang, Yiyin Zhang, Yixiang Zhou, Xinmiao Qu, Xun Zhang, Ke Li, Hanfu Shi, Hui Lin, Shu Wang, et al.

    Accurate intraoperative differentiation between malignant and benign breast tissues, particularly the assessment of lymph node status and tumor margins, is critical for surgical decision-making and prognosis. Traditional histopathological methods, such as frozen section analysis, are time-consuming and labor-intensive. Magnetic Particle Imaging (MPI) is a novel, radiation-free modality that senses the microenvironmental properties of tissues through the dynamic response of magnetic tracers. In this study, we propose a diagnostic method utilizing the higher-order harmonic response of magnetic nanoparticles. Various ex vivo breast tissue samples were immersed in Synomag-50 nanoparticles. Using a custom-built MPI spectrometer (5 kHz excitation, 9 mT amplitude) operating in spectroscopic mode, we implemented a rapid acquisition protocol in which each sample was measured 10 times, with 0.1 s per cycle. We analyzed the magnetic response spectrum and calculated the ratio of the third to the fifth harmonic (H3/H5). Histological analysis confirmed the effective infiltration of MNPs into the interstitial spaces. The repeated measurement data demonstrated high stability. A distinct stepwise increase in harmonic ratios was observed from normal tissue to tumor-adjacent tissue and finally to malignant tumors. Specifically, malignant samples showed ratios that generally exceeded 2.2, whereas benign samples remained below 2.0. These preliminary findings suggest that the harmonic ratio could serve as a sensitive biomarker reflecting the microenvironmental constraints associated with malignancy. This study validates the feasibility of utilizing MPI signal harmonics as a quantitative metric with rapid signal acquisition capabilities for differentiating benign and malignant lymph nodes.