Johan R. Villanueva Medina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Johan R. Villanueva Medina has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Flores
Department of Earth, Environment, and Equity, Howard University, Washington, DC 20059, USA
2 shared publications - Nakul Nitin Karle
Deparment of Earth, Environment and Equity, Howard University, Washington, DC 20059, USA
2 shared publications - Ricardo K. Sakai
Department of Earth, Environment, and Equity, Howard University, Washington, DC 20059, USA
2 shared publications - Daja R. Elum
Deparment of Earth, Environment and Equity, Howard University, Washington, DC 20059, USA
1 shared publication - Joseph L. Wilkins
Department of Earth, Environment, and Equity Howard University Washington DC USA
1 shared publication - Monique Walker
National Geospatial Intelligence Agency, 7500 GEOINT Drive, Springfield, VA 22150, USA
1 shared publication
Latest Publications
- Open Access
- 21 August 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (16) , 2840
Tracking Total Precipitable Water Vapor: A Multi-Instrument Comparative Analysis
Atmospheric water vapor is a major driver of Earth’s climate, yet despite its vital role in driving extreme weather and informing Numerical Weather Prediction (NWP) models, precise quantification of Precipitable Water Vapor (PWV) remains a challenge due to its high spatial and temporal variability. To provide an upgraded evaluation reflecting the most recent data and next-generation instrumentation, this study evaluates the accuracy, relative to radiosonde measurements, in calculating PWV values across six different instruments: Microwave Radiometer (MWR), NOAA-21, TROPOMI, Pandora spectrometer, AERONET sun-photometer, and GNSS/GPS against the bias-corrected Vaisala RS-92 and RS-41 radiosondes over Beltsville, Maryland, utilizing an updated 2024–2025 database. As a certified GRUAN site, HUBC adheres to strict international observation standards designed specifically to provide reference-quality data and comprehensive corrections for systematic errors. This rigorous framework justifies their application as the definitive ‘referent truth’ benchmark for remote sensing validation. RMSE and bias were the primary metrics used to assess relative accuracy. GPS measurements provided the highest level of relative accuracy, yielding the lowest RMSE (1.50 mm) and a near-unity linear fit (y = 0.98x). NOAA-21 and TROPOMI exhibit higher random noise when compared to ground-based instrumentation, yet both obtain high relative accuracy retrievals with negligible biases. AERONET and Pandora also showed strong performance with low RMSEs and R2 values of 0.986 and 0.988, respectively, while slightly underestimating PWV. In contrast, the Radiometer performed with the lowest relative accuracy, characterized by the highest RMSE (6.19 mm) and a significant negative bias (−5.55 mm). Although all instruments maintained high correlation coefficients (R2 ≥ 0.904), these results indicate that satellite and ground-based remote sensing provide reliable PWV retrievals, while GPS presents the most robust benchmark for high-accuracy PWV retrievals relative to radiosonde measurements. The findings also underscore the need for instrument-specific calibration constants to better align remote sensing retrievals with in situ observations.
- 21 August 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (16) , 2840
Open AccessTracking Total Precipitable Water Vapor: A Multi-Instrument Comparative Analysis
Atmospheric water vapor is a major driver of Earth’s climate, yet despite its vital role in driving extreme weather and informing Numerical Weather Prediction (NWP) models, precise quantification of Precipitable Water Vapor (PWV) remains a challenge due to its high spatial and temporal variability. To provide an upgraded evaluation reflecting the most recent data and next-generation instrumentation, this study evaluates the accuracy, relative to radiosonde measurements, in calculating PWV values across six different instruments: Microwave Radiometer (MWR), NOAA-21, TROPOMI, Pandora spectrometer, AERONET sun-photometer, and GNSS/GPS against the bias-corrected Vaisala RS-92 and RS-41 radiosondes over Beltsville, Maryland, utilizing an updated 2024–2025 database. As a certified GRUAN site, HUBC adheres to strict international observation standards designed specifically to provide reference-quality data and comprehensive corrections for systematic errors. This rigorous framework justifies their application as the definitive ‘referent truth’ benchmark for remote sensing validation. RMSE and bias were the primary metrics used to assess relative accuracy. GPS measurements provided the highest level of relative accuracy, yielding the lowest RMSE (1.50 mm) and a near-unity linear fit (y = 0.98x). NOAA-21 and TROPOMI exhibit higher random noise when compared to ground-based instrumentation, yet both obtain high relative accuracy retrievals with negligible biases. AERONET and Pandora also showed strong performance with low RMSEs and R2 values of 0.986 and 0.988, respectively, while slightly underestimating PWV. In contrast, the Radiometer performed with the lowest relative accuracy, characterized by the highest RMSE (6.19 mm) and a significant negative bias (−5.55 mm). Although all instruments maintained high correlation coefficients (R2 ≥ 0.904), these results indicate that satellite and ground-based remote sensing provide reliable PWV retrievals, while GPS presents the most robust benchmark for high-accuracy PWV retrievals relative to radiosonde measurements. The findings also underscore the need for instrument-specific calibration constants to better align remote sensing retrievals with in situ observations.
- Open Access
- 9 February 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (4) , 549
High Resolution UAV-Based Monitoring of Ambient Methane: Field Deployment and Intercomparison with Reference Standards
This study investigates the spatiotemporal variability of ambient methane (CH4) using a drone-deployable Aeris Technologies MIRA Strato LDS midwave-infrared analyzer. Laboratory calibration with NOAA-certified gas standards and Standard Reference Material (SRM) for CH4 demonstrated high measurement precision across a range of concentrations (R2 = 0.9986, slope = 0.9678). Field validation conducted during a two-week intercomparison with a Picarro G2301 in September 2023 confirmed the MIRA Strato’s reliability under ambient conditions (R2 = 0.9845; slope = 0.9438), indicating strong agreement with the reference analyzer. Diurnal patterns revealed peak CH4 concentrations (~2.2 ppm) between 04:00–08:00 LT and minima (~2.1 ppm) between 13:00–17:00 LT, consistent with nocturnal boundary-layer stability and daytime convective mixing. Across 14 midday UAV flights from October 2023 to September 2024, CH4–altitude slopes ranged from −3.05 × 10−4 to +1.41 × 10−4 ppm/m, reflecting variable stratification and uplift regimes. The highest flight concentration (2.23 ppm) was observed on 19 October under stable conditions, while the lowest (2.03 ppm) was observed on 14 August under elevated vertical mixing. These extremes reflect seasonal background accumulation and convective transport effects. Temperature was the most consistent predictor, with regression coefficients ranging from −0.021 to +0.008 ppm/°C, while ethane (C2H6) coefficients were significant but confounded due to measurements below detection limits. The analyzer maintained strong signal stability throughout (mean CV ≈ 0.0066; max = 0.0114), and remote sensing validation with TROPOMI supported observed seasonal accumulation trends. These results demonstrate the MIRA Strato’s capability to resolve near-surface CH4 dynamics and characterize convective transport in complex atmospheric environments.
- 9 February 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (4) , 549
Open AccessHigh Resolution UAV-Based Monitoring of Ambient Methane: Field Deployment and Intercomparison with Reference Standards
This study investigates the spatiotemporal variability of ambient methane (CH4) using a drone-deployable Aeris Technologies MIRA Strato LDS midwave-infrared analyzer. Laboratory calibration with NOAA-certified gas standards and Standard Reference Material (SRM) for CH4 demonstrated high measurement precision across a range of concentrations (R2 = 0.9986, slope = 0.9678). Field validation conducted during a two-week intercomparison with a Picarro G2301 in September 2023 confirmed the MIRA Strato’s reliability under ambient conditions (R2 = 0.9845; slope = 0.9438), indicating strong agreement with the reference analyzer. Diurnal patterns revealed peak CH4 concentrations (~2.2 ppm) between 04:00–08:00 LT and minima (~2.1 ppm) between 13:00–17:00 LT, consistent with nocturnal boundary-layer stability and daytime convective mixing. Across 14 midday UAV flights from October 2023 to September 2024, CH4–altitude slopes ranged from −3.05 × 10−4 to +1.41 × 10−4 ppm/m, reflecting variable stratification and uplift regimes. The highest flight concentration (2.23 ppm) was observed on 19 October under stable conditions, while the lowest (2.03 ppm) was observed on 14 August under elevated vertical mixing. These extremes reflect seasonal background accumulation and convective transport effects. Temperature was the most consistent predictor, with regression coefficients ranging from −0.021 to +0.008 ppm/°C, while ethane (C2H6) coefficients were significant but confounded due to measurements below detection limits. The analyzer maintained strong signal stability throughout (mean CV ≈ 0.0066; max = 0.0114), and remote sensing validation with TROPOMI supported observed seasonal accumulation trends. These results demonstrate the MIRA Strato’s capability to resolve near-surface CH4 dynamics and characterize convective transport in complex atmospheric environments.