Biyuan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Biyuan Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Tao Ding
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710079, China
5 shared publications Tianyou Xue
3 shared publicationsHua Zhang
2 shared publicationsJun Guo
North China Branch of State Grid Corporation of China
2 shared publicationsYantao Zhang
State Grid Electric Power Research Institute (NARI Group Corporation)
2 shared publicationsYuzheng Liu
School of Electrical Engineering Xi'an Jiaotong University Xi'an China
2 shared publications
Latest Publications
- 10 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 257
Non-iterative Lagrangian relaxation to schedule industrial power generators considering prohibited operational zones
- 10 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 257
Non-iterative Lagrangian relaxation to schedule industrial power generators considering prohibited operational zones
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70470
Sparse Ordered‐Binary Formulation for Committed‐Number‐Controlled Transmission Constraints in Security‐Constrained Unit Commitment
Security‐constrained unit commitment is a fundamental optimization problem in power system operations. Conditional transmission constraints, whose limit values dynamically depend on the number of online committed units, introduce computational challenges due to the binary variables required for level selection. This paper proposes a sparse formulation based on ordered binary variables to model these constraints. By representing the staircase function with an ordered binary sequence, the proposed formulation achieves the same linear programming relaxation tightness as the interval‐selection method while reducing binary variables and non‐zero entries. The ordered sequence associated with a given unit group is constructed only once and can be shared across multiple transmission sections controlled by the same committed‐number condition, which eliminates redundant auxiliary variables. Numerical results on three test systems show speedups over the conventional approach.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70470
Open AccessSparse Ordered‐Binary Formulation for Committed‐Number‐Controlled Transmission Constraints in Security‐Constrained Unit Commitment
Security‐constrained unit commitment is a fundamental optimization problem in power system operations. Conditional transmission constraints, whose limit values dynamically depend on the number of online committed units, introduce computational challenges due to the binary variables required for level selection. This paper proposes a sparse formulation based on ordered binary variables to model these constraints. By representing the staircase function with an ordered binary sequence, the proposed formulation achieves the same linear programming relaxation tightness as the interval‐selection method while reducing binary variables and non‐zero entries. The ordered sequence associated with a given unit group is constructed only once and can be shared across multiple transmission sections controlled by the same committed‐number condition, which eliminates redundant auxiliary variables. Numerical results on three test systems show speedups over the conventional approach.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70310
Convex Hull Model for Optimal Self‐Scheduling of the Thermal Unit Considering Deep Peak Regulation
Optimal self‐scheduling of the thermal unit (OSSTU) is typically formulated as a mixed‐integer linear programming (MILP), which is NP‐hard. When deep peak regulation (DPR) is considered, additional integer variables are introduced, significantly increasing the computational burden. To address this challenge, this paper proposes a convex hull formulation to precisely and efficiently solve the OSSTU considering DPR. To be more specific, we prove that the optimal power outputs of the DPR‐constrained OSSTU lie within a finite discrete set. Based on this structure, the original MILP can be reformulated as a backward dynamic programming problem, which is further transformed into a tractable linear programming (LP). Then, the optimal self‐scheduling strategy is obtained from the dual solution of the LP, ensuring that the proposed method can solve this problem in polynomial time. Numerical experiments validate its effectiveness.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70310
Open AccessConvex Hull Model for Optimal Self‐Scheduling of the Thermal Unit Considering Deep Peak Regulation
Optimal self‐scheduling of the thermal unit (OSSTU) is typically formulated as a mixed‐integer linear programming (MILP), which is NP‐hard. When deep peak regulation (DPR) is considered, additional integer variables are introduced, significantly increasing the computational burden. To address this challenge, this paper proposes a convex hull formulation to precisely and efficiently solve the OSSTU considering DPR. To be more specific, we prove that the optimal power outputs of the DPR‐constrained OSSTU lie within a finite discrete set. Based on this structure, the original MILP can be reformulated as a backward dynamic programming problem, which is further transformed into a tractable linear programming (LP). Then, the optimal self‐scheduling strategy is obtained from the dual solution of the LP, ensuring that the proposed method can solve this problem in polynomial time. Numerical experiments validate its effectiveness.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Two‐Stage Robust Security‐Constrained Unit Commitment for Wind Power Reserve Provision Optimisation Under Decision‐Dependent Uncertainty
To address the challenge brought by the wind power uncertainty to power system scheduling, this paper proposes a two‐stage robust security‐constrained unit commitment (RSCUC) model for wind power reserve provision, considering the impact of optimal decisions on the uncertainty set. In the first stage (pre‐scheduling stage), the curtailment plan of wind power is made and the wind power reserve is optimised, where the curtailment plan will influence the wind power uncertainty, giving rise to a decision‐dependent uncertainty (DDU) set. In the second stage (re‐scheduling stage), the thermal unit redispatch and the wind power reserve are allowed to keep the system balanced. The two‐stage RSCUC model with DDU can be solved by reformulating DDU into decision‐independent uncertainty, and the column‐and‐constraint generation algorithm is employed. Numerical results verify the effectiveness of the proposed model.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessTwo‐Stage Robust Security‐Constrained Unit Commitment for Wind Power Reserve Provision Optimisation Under Decision‐Dependent Uncertainty
To address the challenge brought by the wind power uncertainty to power system scheduling, this paper proposes a two‐stage robust security‐constrained unit commitment (RSCUC) model for wind power reserve provision, considering the impact of optimal decisions on the uncertainty set. In the first stage (pre‐scheduling stage), the curtailment plan of wind power is made and the wind power reserve is optimised, where the curtailment plan will influence the wind power uncertainty, giving rise to a decision‐dependent uncertainty (DDU) set. In the second stage (re‐scheduling stage), the thermal unit redispatch and the wind power reserve are allowed to keep the system balanced. The two‐stage RSCUC model with DDU can be solved by reformulating DDU into decision‐independent uncertainty, and the column‐and‐constraint generation algorithm is employed. Numerical results verify the effectiveness of the proposed model.