Kiran Veernapu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kiran Veernapu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Adinarayana Andy
Mass General Brigham, USA
1 shared publication - Aman Suresh Tharayil
Dr. M.G.R. Educational and Research Institute, India
1 shared publication - Anmol Shankarrao Budhewar
Sandip Institute of Technology and Research Centre, Nashik, India
1 shared publication - Balkrishna Keshavrao Patil
Sandip Institute of Technology and Research Centre, Nashik, India
1 shared publication - C.L Sindhura
Narayana Pharmacy College, India
1 shared publication Debabrata Biswas
1 shared publication
Latest Publications
- Open Access
- 30 June 2026
- Published by AAN Publishing in Journal of Computers, Mechanical and Management
- Vol. 5 (3)
Healthcare-Centric Confidence Assessment of Machine Learning Models via Average Precision and Feature-Subset Stability
The paper presents a confidence-based assessment system of machine learning models which uses the Average Precision (AP) which is the result of the precision-recall curve as a threshold-agnostic ranking metric and indicator of operational reliability. This method is not based on the accuracy of the class-labels of the model like the traditional metrics, but the consistency of the model performance at the entire range of decision thresholds. To act as an experimental test bed, a one-dimensional convolutional neural network (1D CNN) was trained using the Breast Cancer Wisconsin (Diagnostic) dataset. Permutation based feature importance was done after full-feature baseline AP to measure the AP degradation on a feature-by-feature basis and an even higher-order subset, such as pairs, triplets and quadruplets. Empirical analysis revealed worst concave points, worst concavity and mean texture as the main factors of individual AP drops. Within higher-order subsets, worst concavity, worst radius and mean texture always prevailed in the AP-based reliability profile. It is interesting to note that several four-feature combinations produced an AP score of the same size as or greater than the baseline of 30 features, which indicates a high level of informational redundancy. AP functions as a stable threshold-agnostic ranking and operational-performance measure, not as direct probabilistic confidence, as evidenced by its consistently high AP (>0.95) across operating thresholds. The paper finds that high AP-based operational reliability does not necessitate a complete feature set, but instead the consistency of AP-based reliability in small feature sets increases the interpretability, trust and deployability of machine learning systems in the studied medical diagnostic setting and in related safety-critical applications pending external validation.
- 30 June 2026
- Published by AAN Publishing in Journal of Computers, Mechanical and Management
- Vol. 5 (3)
Open AccessHealthcare-Centric Confidence Assessment of Machine Learning Models via Average Precision and Feature-Subset Stability
The paper presents a confidence-based assessment system of machine learning models which uses the Average Precision (AP) which is the result of the precision-recall curve as a threshold-agnostic ranking metric and indicator of operational reliability. This method is not based on the accuracy of the class-labels of the model like the traditional metrics, but the consistency of the model performance at the entire range of decision thresholds. To act as an experimental test bed, a one-dimensional convolutional neural network (1D CNN) was trained using the Breast Cancer Wisconsin (Diagnostic) dataset. Permutation based feature importance was done after full-feature baseline AP to measure the AP degradation on a feature-by-feature basis and an even higher-order subset, such as pairs, triplets and quadruplets. Empirical analysis revealed worst concave points, worst concavity and mean texture as the main factors of individual AP drops. Within higher-order subsets, worst concavity, worst radius and mean texture always prevailed in the AP-based reliability profile. It is interesting to note that several four-feature combinations produced an AP score of the same size as or greater than the baseline of 30 features, which indicates a high level of informational redundancy. AP functions as a stable threshold-agnostic ranking and operational-performance measure, not as direct probabilistic confidence, as evidenced by its consistently high AP (>0.95) across operating thresholds. The paper finds that high AP-based operational reliability does not necessitate a complete feature set, but instead the consistency of AP-based reliability in small feature sets increases the interpretability, trust and deployability of machine learning systems in the studied medical diagnostic setting and in related safety-critical applications pending external validation.
- Top Cited Papers
- 22 January 2026
- Published by IGI Global Scientific Publishing
- p. 431-452
Real-time AI in Clinical Decision Support
The integration of real-time artificial intelligence (AI) into Clinical Decision Support Systems (CDSS) marks a turning point in the evolution of modern healthcare. Traditional CDSS relied on retrospective or rule-based reasoning, offering insights only after data were finalized. In contrast, real-time AI enables continuous interpretation of live data streams from bedside monitors and laboratory systems to imaging and wearable devices transforming static analytics into adaptive, situational intelligence. This chapter examines how real-time AI can transition from successful experimentation to consistent clinical deployment. It explores the technical architectures that make real-time processing feasible, as well as the ethical, operational, and regulatory challenges that arise when algorithms move from laboratory settings to patient care environments.
- 22 January 2026
- Published by IGI Global Scientific Publishing
- p. 431-452
Top Cited PapersReal-time AI in Clinical Decision Support
The integration of real-time artificial intelligence (AI) into Clinical Decision Support Systems (CDSS) marks a turning point in the evolution of modern healthcare. Traditional CDSS relied on retrospective or rule-based reasoning, offering insights only after data were finalized. In contrast, real-time AI enables continuous interpretation of live data streams from bedside monitors and laboratory systems to imaging and wearable devices transforming static analytics into adaptive, situational intelligence. This chapter examines how real-time AI can transition from successful experimentation to consistent clinical deployment. It explores the technical architectures that make real-time processing feasible, as well as the ethical, operational, and regulatory challenges that arise when algorithms move from laboratory settings to patient care environments.