PBPavel Belina

Pavel Belina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pavel Belina has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy of COMPASS Upgrade equilibrium reconstruction

    by M Vanakova, T Markovic, S Marchioni, L Kripner, M Imrisek, D Fridrich, O Kovanda, P Belina, V Veselovsky, Compass Upgrade Team

    We carry out an analysis of the reconstruction accuracy of plasma equilibrium during the plasma current flat-top phase of the tokamak COMPASS Upgrade, utilizing the codes EFIT and LIUQE. We do so for the nominal set of input synthetic magnetic diagnostic signals, as well as those with varying degrees of introduced measurement errors (normal distribution with 2% standard deviation) within 75 Monte Carlo data set inputs. The analysis was performed for three COMPASS Upgrade baseline scenarios using the measurements of standard and backup magnetic diagnostics set, and for a case study of missing magnetic sensors on the low field side. We show that both in the absence of measurement errors as well as for conservative estimates of 2% error, the reconstruction accuracy of LIUQE code is within the 1 cm limit, albeit approaching it at the top and bottom of the plasma column. EFIT also performs well in the absence of input measurement errors, but with errors included the inaccuracy of the reconstruction reaches slightly above the error limits at several positions. We conclude that the utilization of LIUQE for tokamak COMPASS Upgrade plasma control will be viable, albeit real-time implementation of the reconstruction algorithms will have to be the subject of our future work.

  • Open Access

    Design of the soft x-ray spectrometer for observing high- Z elements at the full-metal COMPASS Upgrade tokamak

    by Vladimir Weinzettl, Jens Rauschenberger, Tobias Wilken, Pavel Belina, Jaroslav Cerovsky, Amelie Grudinova, Adam Zak

    A compact and highly flexible soft x-ray (SXR) spectrometer for measuring electromagnetic radiation, primarily in the spectral range of about 2–8 keV, was designed with the aim of monitoring of highly ionized, mainly high- Z metallic impurities in the core of high temperature plasmas at the COMPASS Upgrade tokamak (currently under construction) with core plasma temperatures of ∼1–5 keV and core electron densities of ∼1–3 * 10 20 m −3 . These impurities will originate from plasma interaction with plasma-facing components made of tungsten and nickel–chromium-based alloys (Inconel), containing elements such as nickel, chromium, molybdenum and iron. The SXR spectrometer will enable the monitoring of each of these elements by resolving well their characteristic spectral lines in pre-selected spectral regions of interest. Additionally, information on the electron and ion temperature in the plasma core will be provided using artificially introduced impurities such as argon. The main technical parameters of the SXR spectrometer are as follows: Johann geometry using spherical Bragg crystals, back-illuminated charge-coupled device as a detector in a fixed position, pre-selected spectral regions of interest for metallic (W, Mo, Fe, Cr, Ni) and gaseous (Ar) impurities in the spectral region 2.4–8.1 keV (0.52–0.15 nm), spectral resolution about 2500, but better than 3000 for the Ar lines near 3.1 keV, time resolution about 40 ms, compact size (the core of the spectrometer of about 1 m by 1 m; 2.5 m long vacuum connection duct to the tokamak cryostat edge) and flexible configuration (remotely driven crystal exchanger, left–right spectrometer set-up flexibility, differential pumping). The contribution introduces the design of the spectrometer itself as well as future plans for its implementation in the tokamak hall in early operational phases with low hard radiation or in a shielded area outside the tokamak hall for high-performance plasmas at COMPASS Upgrade.

  • Open Access

    Design of ultra-fast soft x-ray sensorics for spectral monitoring of high-temperature plasmas

    by A Havranek, D Kekrt, M Imrisek, V Weinzettl, P Belina, J Svoboda, P Svihra, L Tomasek, M Kuncova, Z Janoska, et al.

    The 2D ultra-fast soft x-ray sensorics for spectral monitoring of high-temperature plasmas opens the possibility to study spectrally resolved emission in the 4–20 keV range with a typical spatial resolution of several millimeters on a sub-millisecond scale. The camera core consists of an innovative monolithic active pixel sensor, derived from the SpacePix3 sensor family, capable of measuring individual photon energies, complemented by system-on-chip-based readout electronics and an optical link. We present a design that targets the harsh environments near fusion devices, therefore fully aimed at remote control. The design offers high flexibility for adjusting the camera field-of-view and spatial resolution, even with the pixel sensor located in a vacuum. As a differentially pumped diagnostic with an entrance gate valve, the camera can be easily mounted to or dismounted from the device. The use and integration of the camera is supported by an Ethernet interface, HDF5 data format, web interface, and C++ library. The initial sensor tests, based on the measurement of ⁵ ⁵ Fe emitter x-ray spectra and the energy calibration curve, are presented.