Christine Vo
Christine Vo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kelly Zhang
Synthetic Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States
2 shared publications Raymond Lieu
Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, USA
2 shared publications- Tao Chen
Synthetic Molecule Analytical Chemistry, Synthetic Molecule Pharmaceutical Sciences, Genentech, Inc., 1 DNA Way, South San Francisco, California 94080, United States
2 shared publications - Wan-Chih Su
Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, USA
2 shared publications - Yuchen Fan
Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, USA
2 shared publications - Szabolcs Fekete
Waters Corporation, Geneva, Switzerland
1 shared publication
Latest Publications
- 23 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1776, 466928
High-throughput mRNA poly(A) tail characterization through on-off retention ion-exchange chromatography
- 23 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1776, 466928
High-throughput mRNA poly(A) tail characterization through on-off retention ion-exchange chromatography
- Open Access
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
High-Throughput mRNA Poly(A) Tail Characterization Through On-Off Retention Ion-Exchange Chromatography
Limited chromatographic resolution of large nucleic acids remains a major bottleneck in the development of high-throughput analytical platforms for mRNA therapeutics. Here, we report a pronounced on-off elution behavior of oligonucleotides and mRNA under strong ion-exchange (IEX) conditions, using a normalized linear ionic strength model. This discovery fundamentally redefines solvent-strength scaling in IEX and enables rapid separations of oligonucleotides and mRNA on ultra-short columns. Leveraging this on-off elution behavior, two complementary high-throughput IEX methods were developed using 5 cm columns under a unified platform (pH 8, 75 °C, lithium perchlorate as the mobile-phase additive). A 6.5-minute gradient achieved baseline separation and quantification of non-poly(A)- and poly(A)-mRNA species for both eGFP and Fluc mRNA, representing the first reported baseline chromatographic separation of intact non-poly(A)- and poly(A)-mRNA. To resolve poly(A) length variants within the oligonucleotide sequence range, a non-linear logarithmic gradient achieved separation of 20-120 nt poly(A) ladders within 4 minutes, enabling high-throughput poly(A) tail length determination. Following one-step RNase T1 digestion, poly(A) tail lengths of 117 nt and 118 nt were determined for eGFP and Fluc mRNA, respectively, in agreement with theoretical values. Collectively, this work establishes on-off elution behavior as a defining retention regime in IEX and demonstrates it as a powerful strategy for high-throughput characterization of mRNA poly(A) content and tail length, with strong potential to support process development and quality control of mRNA therapeutics.
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-Throughput mRNA Poly(A) Tail Characterization Through On-Off Retention Ion-Exchange Chromatography
Limited chromatographic resolution of large nucleic acids remains a major bottleneck in the development of high-throughput analytical platforms for mRNA therapeutics. Here, we report a pronounced on-off elution behavior of oligonucleotides and mRNA under strong ion-exchange (IEX) conditions, using a normalized linear ionic strength model. This discovery fundamentally redefines solvent-strength scaling in IEX and enables rapid separations of oligonucleotides and mRNA on ultra-short columns. Leveraging this on-off elution behavior, two complementary high-throughput IEX methods were developed using 5 cm columns under a unified platform (pH 8, 75 °C, lithium perchlorate as the mobile-phase additive). A 6.5-minute gradient achieved baseline separation and quantification of non-poly(A)- and poly(A)-mRNA species for both eGFP and Fluc mRNA, representing the first reported baseline chromatographic separation of intact non-poly(A)- and poly(A)-mRNA. To resolve poly(A) length variants within the oligonucleotide sequence range, a non-linear logarithmic gradient achieved separation of 20-120 nt poly(A) ladders within 4 minutes, enabling high-throughput poly(A) tail length determination. Following one-step RNase T1 digestion, poly(A) tail lengths of 117 nt and 118 nt were determined for eGFP and Fluc mRNA, respectively, in agreement with theoretical values. Collectively, this work establishes on-off elution behavior as a defining retention regime in IEX and demonstrates it as a powerful strategy for high-throughput characterization of mRNA poly(A) content and tail length, with strong potential to support process development and quality control of mRNA therapeutics.