Jiale Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiale Sun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ao Sheng
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213251, China
1 shared publication - Libin Li
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213251, China
1 shared publication - Rugao He
Laisai Laser Technology Co., Ltd., Changzhou 213100, China
1 shared publication - Shudong Zhuang
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213200, China
1 shared publication - Ying Zou
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213251, China
1 shared publication - Yu Wan
College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213251, China
1 shared publication
Latest Publications
- Open Access
High-Fidelity Modeling of Laser Levels via Pulse-Window Software Lock-In PSD Sensing
Accurate identification of dynamic parameters, specifically natural frequency and damping ratio, is critical for optimizing the disturbance rejection performance of laser level self-leveling mechanisms. However, traditional Finite Element Analysis (FEA) often struggles to quantify micro-friction damping, while contact measurement methods introduce added mass interference. To address these challenges, this paper proposes an integrated framework combining Pulse-Window Software Lock-in (PWSL) sensing with a data-driven model updating strategy. Initially, a rigid-body dynamic model theoretically predicted a natural frequency (fsim) of 2.987 Hz and a damping ratio (ζsim) of 0.1255. To acquire authentic responses, a non-contact Position Sensitive Detector (PSD) system was developed. The custom PWSL algorithm leverages the laser’s 10 kHz carrier to extract high-fidelity displacement signals, effectively suppressing broadband noise despite embedded hardware limitations. Experimental results demonstrated that the measured frequency (fexp = 2.861 Hz) aligned well with predictions (4.22% error). In contrast, the measured damping ratio (ζexp = 0.1435) exceeded the simulation value by 14.34%, quantitatively revealing the energy dissipation caused by unmodeled bearing friction. Based on this disparity, the FEA model was inversely updated by introducing an equivalent friction coefficient, successfully reducing the damping prediction error to 0.97%. This study establishes a high-fidelity updated model, providing a reliable basis for the refined design of precision pendulum instruments.
Open AccessHigh-Fidelity Modeling of Laser Levels via Pulse-Window Software Lock-In PSD Sensing
Accurate identification of dynamic parameters, specifically natural frequency and damping ratio, is critical for optimizing the disturbance rejection performance of laser level self-leveling mechanisms. However, traditional Finite Element Analysis (FEA) often struggles to quantify micro-friction damping, while contact measurement methods introduce added mass interference. To address these challenges, this paper proposes an integrated framework combining Pulse-Window Software Lock-in (PWSL) sensing with a data-driven model updating strategy. Initially, a rigid-body dynamic model theoretically predicted a natural frequency (fsim) of 2.987 Hz and a damping ratio (ζsim) of 0.1255. To acquire authentic responses, a non-contact Position Sensitive Detector (PSD) system was developed. The custom PWSL algorithm leverages the laser’s 10 kHz carrier to extract high-fidelity displacement signals, effectively suppressing broadband noise despite embedded hardware limitations. Experimental results demonstrated that the measured frequency (fexp = 2.861 Hz) aligned well with predictions (4.22% error). In contrast, the measured damping ratio (ζexp = 0.1435) exceeded the simulation value by 14.34%, quantitatively revealing the energy dissipation caused by unmodeled bearing friction. Based on this disparity, the FEA model was inversely updated by introducing an equivalent friction coefficient, successfully reducing the damping prediction error to 0.97%. This study establishes a high-fidelity updated model, providing a reliable basis for the refined design of precision pendulum instruments.