Sulagna Sarkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sulagna Sarkar has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Akbar Nawaz Syed
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
1 shared publication Alberto Daniel Navarro Vergara
Hospital de Trauma Manuel Giagni, Asunción Paraguay, Asunción, Paraguay
1 shared publication- Alexandra M. Olson
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
1 shared publication - Alexandre Arkader
Children’s Hospital of Philadelphia, Orthopedic Center, Philadelphia, PA
1 shared publication - Ambika Nair
The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
1 shared publication - Apurva S. Shah
Division of Orthopaedics, The Children’s Hospital of Philadelphia, Philadelphia, PA
1 shared publication
Latest Publications
- 19 October 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
Principles or Resources? Best Management of Pediatric Femoral Neck Fractures
Background: Pediatric femoral neck fractures (PFNF) are rare but have a reported complication rate of >30%. To date, there remains a lack of consensus on the definitive risk factors for AVN following PFNF. By comparing the outcomes of PFNF treated at a major US metropolitan area tertiary-level 1 pediatric trauma center (group 1) to an equivalent trauma hospital in a major Latin American capital (group 2), we sought to weigh whether treatment principles or resources are more important for a favorable result. Methods: This was a retrospective review of all children (P P =0.01) while no other differences in fracture characteristics were observed between groups. Of the patients who underwent operative treatment for their fractures, the time to surgery was significantly shorter in group 1 (4.42 days) compared with group 2 (7.56 days, P 0.05). Conclusion: While these 2 institutions differ in resources, such as the ability to perform surgery urgently or hardware availability, and despite differences in fracture type, there were no significant differences in the outcome and incidence of complications, including AVN. Levels of Evidence: Level 3, Retrospective comparative study.
- 19 October 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
Principles or Resources? Best Management of Pediatric Femoral Neck Fractures
Background: Pediatric femoral neck fractures (PFNF) are rare but have a reported complication rate of >30%. To date, there remains a lack of consensus on the definitive risk factors for AVN following PFNF. By comparing the outcomes of PFNF treated at a major US metropolitan area tertiary-level 1 pediatric trauma center (group 1) to an equivalent trauma hospital in a major Latin American capital (group 2), we sought to weigh whether treatment principles or resources are more important for a favorable result. Methods: This was a retrospective review of all children (P P =0.01) while no other differences in fracture characteristics were observed between groups. Of the patients who underwent operative treatment for their fractures, the time to surgery was significantly shorter in group 1 (4.42 days) compared with group 2 (7.56 days, P 0.05). Conclusion: While these 2 institutions differ in resources, such as the ability to perform surgery urgently or hardware availability, and despite differences in fracture type, there were no significant differences in the outcome and incidence of complications, including AVN. Levels of Evidence: Level 3, Retrospective comparative study.
- 19 October 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
Outcomes Related to the Use of Standard-Standard versus Standard-Offset Magnetically Controlled Growing Rods
Background: Magnetically controlled growing rods (MCGRs) are used to perform growth-friendly spinal deformity correction. A key variable that remains debated in determining the optimal use of MCGRs is the orientation of the rods: parallel to one another (standard-standard) versus antiparallel (standard-offset). This study aims to determine if the orientation of the rods has an impact on lengthening outcomes and complication rates. Methods: A retrospective analysis of an international multicenter prospective registry of early-onset scoliosis patients was conducted. Inclusion criteria were patients who underwent bilateral MCGR index surgery with available lengthening data for a minimum of 2 years. Lengthening analyses were discontinued following revision or exchange of the implants. Accumulated programmed and actual lengthening was recorded at the first visit, 2-year, and 5-year intervals following index surgery. Results: Six hundred sixty-eight patients met the inclusion criteria for the study, including 327 females (49%) and 341 males (51%) patients who were 8.0±1.9 years old at index surgery, with a mean major coronal curve of 74 degrees (18 to 134 degrees). Three hundred twenty-three (48%) patients received standard-standard and 345 (52%) patients received standard-offset MCGRs. Patients with standard-standard rods experienced complications at a similar rate to patients who received standard-offset rods [n=137 (42%) vs. n=128 (37%); P =0.161]. In terms of achieved lengthening, no differences were found across actuator orientations at the first lengthening, or in the achieved lengthening accumulated by patients who were still undergoing lengthening procedures at 2 or 5 years post-implantation. Conclusions: The lengthening achieved and complication risks are similar across rod orientations at 2 and 5 years. At 2 years post-index surgery, surgeons appear to be attempting to lengthen patients who receive standard-offset rods to a greater extent without any additional clinical benefit. Further investigation is needed to further elucidate the best practices of MCGR utilization and to determine which patients would benefit from one orientation compared with the other. Level of Evidence: Level 3.
- 19 October 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
Outcomes Related to the Use of Standard-Standard versus Standard-Offset Magnetically Controlled Growing Rods
Background: Magnetically controlled growing rods (MCGRs) are used to perform growth-friendly spinal deformity correction. A key variable that remains debated in determining the optimal use of MCGRs is the orientation of the rods: parallel to one another (standard-standard) versus antiparallel (standard-offset). This study aims to determine if the orientation of the rods has an impact on lengthening outcomes and complication rates. Methods: A retrospective analysis of an international multicenter prospective registry of early-onset scoliosis patients was conducted. Inclusion criteria were patients who underwent bilateral MCGR index surgery with available lengthening data for a minimum of 2 years. Lengthening analyses were discontinued following revision or exchange of the implants. Accumulated programmed and actual lengthening was recorded at the first visit, 2-year, and 5-year intervals following index surgery. Results: Six hundred sixty-eight patients met the inclusion criteria for the study, including 327 females (49%) and 341 males (51%) patients who were 8.0±1.9 years old at index surgery, with a mean major coronal curve of 74 degrees (18 to 134 degrees). Three hundred twenty-three (48%) patients received standard-standard and 345 (52%) patients received standard-offset MCGRs. Patients with standard-standard rods experienced complications at a similar rate to patients who received standard-offset rods [n=137 (42%) vs. n=128 (37%); P =0.161]. In terms of achieved lengthening, no differences were found across actuator orientations at the first lengthening, or in the achieved lengthening accumulated by patients who were still undergoing lengthening procedures at 2 or 5 years post-implantation. Conclusions: The lengthening achieved and complication risks are similar across rod orientations at 2 and 5 years. At 2 years post-index surgery, surgeons appear to be attempting to lengthen patients who receive standard-offset rods to a greater extent without any additional clinical benefit. Further investigation is needed to further elucidate the best practices of MCGR utilization and to determine which patients would benefit from one orientation compared with the other. Level of Evidence: Level 3.
- 14 July 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 46 (10) , e1004-e1009
Correlation Between Radiographic Parameters and Clinical Range of Motion in Slipped Capital Femoral Epiphysis
Background: Surgical procedures that improve motion for slipped capital femoral epiphysis (SCFE) deformity are typically guided by radiographic imaging. However, the specific aspects of the deformity that have the greatest impact on hip functional biomechanics remain unclear. This study investigated the relationship between radiographic parameters and clinical ROM measurements in patients with SCFE to better elucidate which elements of SCFE pathoanatomy have the greatest effect on joint mobility. Methods: Patients who underwent in situ pinning for stable SCFE at a single institution between 2013 and 2025 were retrospectively reviewed. Patients were excluded if they had unstable SCFE or underwent a modified Dunn osteotomy or simultaneous bilateral SCFE procedures. Demographics and clinical ROM measurements were obtained from the electronic health record. Radiographic parameters, including the Southwick slip angle (SSA), posterior sloping angle (PSA), percent epiphyseal displacement of Wilson (PED), and alpha angle, were measured on immediate postoperative radiographs. ROM deficits were calculated as the difference between affected and unaffected hips. The relationships between radiographic and clinical ROM variables were quantified using linear regressions. Results: Seventy-four hips in 69 patients (mean age 12.3±1.5 y, 50.7% male) were included. In 5 patients, ROM data were available for the contralateral, unaffected hip just before a subsequent slip and were used as control measurements for that hip. Overall, PED had the largest effect on ROM. For every 1% increase in displacement, patients lost an average of 2.18 degrees of flexion ( P P =0.001). SSA, PSA, and AP alpha angle had statistically significant effects on internal rotation in flexion (IRF)—a 1-degree increase in each led to a 0.78, 0.81, and 0.74-degree decrease in IRF, respectively ( P <0.001 for all). The lateral alpha angle had the smallest impact. Conclusions: In children with SCFE, radiographic deformity predicts clinical ROM. PED has the strongest negative association with flexion and abduction, while PSA, SSA, and AP alpha angle have negative associations with IRF. Reconstructive strategies should prioritize correction of these aspects of the SCFE deformity to maximize joint mobility. Level of Evidence: Level III—retrospective comparative study.
- 14 July 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 46 (10) , e1004-e1009
Correlation Between Radiographic Parameters and Clinical Range of Motion in Slipped Capital Femoral Epiphysis
Background: Surgical procedures that improve motion for slipped capital femoral epiphysis (SCFE) deformity are typically guided by radiographic imaging. However, the specific aspects of the deformity that have the greatest impact on hip functional biomechanics remain unclear. This study investigated the relationship between radiographic parameters and clinical ROM measurements in patients with SCFE to better elucidate which elements of SCFE pathoanatomy have the greatest effect on joint mobility. Methods: Patients who underwent in situ pinning for stable SCFE at a single institution between 2013 and 2025 were retrospectively reviewed. Patients were excluded if they had unstable SCFE or underwent a modified Dunn osteotomy or simultaneous bilateral SCFE procedures. Demographics and clinical ROM measurements were obtained from the electronic health record. Radiographic parameters, including the Southwick slip angle (SSA), posterior sloping angle (PSA), percent epiphyseal displacement of Wilson (PED), and alpha angle, were measured on immediate postoperative radiographs. ROM deficits were calculated as the difference between affected and unaffected hips. The relationships between radiographic and clinical ROM variables were quantified using linear regressions. Results: Seventy-four hips in 69 patients (mean age 12.3±1.5 y, 50.7% male) were included. In 5 patients, ROM data were available for the contralateral, unaffected hip just before a subsequent slip and were used as control measurements for that hip. Overall, PED had the largest effect on ROM. For every 1% increase in displacement, patients lost an average of 2.18 degrees of flexion ( P P =0.001). SSA, PSA, and AP alpha angle had statistically significant effects on internal rotation in flexion (IRF)—a 1-degree increase in each led to a 0.78, 0.81, and 0.74-degree decrease in IRF, respectively ( P <0.001 for all). The lateral alpha angle had the smallest impact. Conclusions: In children with SCFE, radiographic deformity predicts clinical ROM. PED has the strongest negative association with flexion and abduction, while PSA, SSA, and AP alpha angle have negative associations with IRF. Reconstructive strategies should prioritize correction of these aspects of the SCFE deformity to maximize joint mobility. Level of Evidence: Level III—retrospective comparative study.
- 9 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
Effectiveness of a Structured Training Program in Pediatric Distal Radial Fracture Reduction for Orthopaedic Advanced Practice Providers
Background: Training programs to prepare novice advanced practice providers (APPs) to reduce fractures have not been described or evaluated. The current study evaluated the effectiveness of a structured training program for APPs to deliver effective fracture care independently in emergency department settings. Methods: We performed a retrospective review of the first 5 independent distal radial fracture reductions performed by each participant. Radiographic measurements and information regarding patient injury, loss of reduction, and the need for surgery due to failure of closed management were collected. Patients were treated by (1) APPs with structured training (APP group), (2) traditionally trained postgraduate year (PGY)-2 residents (TR2), (3) PGY-2 residents with additional simulation training (SR2), and (4) experienced PGY-4 residents (TR4). Results: We identified 136 patients: 28 treated by the APP group; 24, by TR2s; 52, by SR2s; and 32, by TR4s. Significant differences were seen in post-reduction angulation and percent contact, with the APPs and TR4s achieving better initial reductions as indicated by the least residual angulation and greatest percent contact (all p < 0.05). At the time of follow-up, reductions by the APP group had more favorable outcomes, compared with those performed by residents, with respect to angulation on lateral radiographs (p = 0.047) and percent contact on anteroposterior (p = 0.036) and lateral (p = 0.004) radiographs. Reductions performed by the APP group also showed lower rates of loss of reduction (p < 0.001) and subsequent surgery (p = 0.005). Conclusions: APPs receiving structured training prior to independent care delivery achieved better reductions overall, placed better casts, and had lower rates of loss of reduction and subsequent surgery compared with junior orthopaedic residents. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
- 9 July 2026
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
Effectiveness of a Structured Training Program in Pediatric Distal Radial Fracture Reduction for Orthopaedic Advanced Practice Providers
Background: Training programs to prepare novice advanced practice providers (APPs) to reduce fractures have not been described or evaluated. The current study evaluated the effectiveness of a structured training program for APPs to deliver effective fracture care independently in emergency department settings. Methods: We performed a retrospective review of the first 5 independent distal radial fracture reductions performed by each participant. Radiographic measurements and information regarding patient injury, loss of reduction, and the need for surgery due to failure of closed management were collected. Patients were treated by (1) APPs with structured training (APP group), (2) traditionally trained postgraduate year (PGY)-2 residents (TR2), (3) PGY-2 residents with additional simulation training (SR2), and (4) experienced PGY-4 residents (TR4). Results: We identified 136 patients: 28 treated by the APP group; 24, by TR2s; 52, by SR2s; and 32, by TR4s. Significant differences were seen in post-reduction angulation and percent contact, with the APPs and TR4s achieving better initial reductions as indicated by the least residual angulation and greatest percent contact (all p < 0.05). At the time of follow-up, reductions by the APP group had more favorable outcomes, compared with those performed by residents, with respect to angulation on lateral radiographs (p = 0.047) and percent contact on anteroposterior (p = 0.036) and lateral (p = 0.004) radiographs. Reductions performed by the APP group also showed lower rates of loss of reduction (p < 0.001) and subsequent surgery (p = 0.005). Conclusions: APPs receiving structured training prior to independent care delivery achieved better reductions overall, placed better casts, and had lower rates of loss of reduction and subsequent surgery compared with junior orthopaedic residents. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (1)
Development of Apex Volar Deformity Following Volar Plating of Pediatric Radius Fractures
Background: Plate fixation in skeletally immature children can cause angular deformity with longitudinal growth even when the plate does not overlie the adjacent physis. While this phenomenon has been described for the distal femur, angular deformity has not been reported following plating in other long bones. The aim of the study was to characterize whether sagittal-plane deformity occurs following volar plating of radius fractures in skeletally immature children and to determine associated risk factors. Methods: A retrospective review of volar plating of acute radius fractures in children with an open distal radius physis at a single institution was completed. In patients with at least 4 months of follow-up, the first radiograph and the last follow-up radiograph were evaluated for any change in sagittal angulation distal to the plate. Demographic information was obtained from the electronic medical record. Linear regression analysis was used to determine if distance from the plate to the physis, follow-up time, age, or coexisting ulnar fracture was predictive of any observed changes in angulation. Results: Sixty-one acute radius fractures treated with volar plating at a mean age of 12.1 years (67% male, 70.5% White, 90.2% non-Hispanic) were included. When analyzing by fracture location, 78% (21/27) of the distal-third radius fractures with appropriate follow-up developed at least 10° of apex volar angular deformity, with 44% (12/27) exhibiting greater than 20°. Middle-third and proximal-third fractures did not exhibit similar degrees of angulation (only 13% [4/30] and 0% [0/4] of included patients developed more than 10° of deformity, respectively). Linear regression analysis revealed distance of the plate to the physis and follow-up time to be strong predictors of angulation (both p < 0.0001). Conclusions: Children with radius fractures, particularly those in the distal-third, treated with a volar plate may develop apex volar angular deformity. While the exact rate of this phenomenon is unclear, these findings underscore the importance of strict surgical indications and vigilant postoperative monitoring beyond fracture healing, and represent a paradigm shift in understanding growth modulation following plating. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (1)
Open AccessDevelopment of Apex Volar Deformity Following Volar Plating of Pediatric Radius Fractures
Background: Plate fixation in skeletally immature children can cause angular deformity with longitudinal growth even when the plate does not overlie the adjacent physis. While this phenomenon has been described for the distal femur, angular deformity has not been reported following plating in other long bones. The aim of the study was to characterize whether sagittal-plane deformity occurs following volar plating of radius fractures in skeletally immature children and to determine associated risk factors. Methods: A retrospective review of volar plating of acute radius fractures in children with an open distal radius physis at a single institution was completed. In patients with at least 4 months of follow-up, the first radiograph and the last follow-up radiograph were evaluated for any change in sagittal angulation distal to the plate. Demographic information was obtained from the electronic medical record. Linear regression analysis was used to determine if distance from the plate to the physis, follow-up time, age, or coexisting ulnar fracture was predictive of any observed changes in angulation. Results: Sixty-one acute radius fractures treated with volar plating at a mean age of 12.1 years (67% male, 70.5% White, 90.2% non-Hispanic) were included. When analyzing by fracture location, 78% (21/27) of the distal-third radius fractures with appropriate follow-up developed at least 10° of apex volar angular deformity, with 44% (12/27) exhibiting greater than 20°. Middle-third and proximal-third fractures did not exhibit similar degrees of angulation (only 13% [4/30] and 0% [0/4] of included patients developed more than 10° of deformity, respectively). Linear regression analysis revealed distance of the plate to the physis and follow-up time to be strong predictors of angulation (both p < 0.0001). Conclusions: Children with radius fractures, particularly those in the distal-third, treated with a volar plate may develop apex volar angular deformity. While the exact rate of this phenomenon is unclear, these findings underscore the importance of strict surgical indications and vigilant postoperative monitoring beyond fracture healing, and represent a paradigm shift in understanding growth modulation following plating. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.