Latest Publications

  • Open Access

    Size-Specific Dose Estimate Assessment in Adult Non-Contrast Computed Tomography Abdomen: A Cross-Sectional Dose Evaluation Study

    by Satyam Verma, Rohit Sharma, Atul Mishra, Arun Kumar Yadav, Abhishek Kumar, Ajai Kumar Srivastava

    To evaluate and compare conventional radiation dose metrics (computed tomography dose index volume [CTDIvol] and dose length product [DLP]) with size-specific dose estimates (SSDEs) in adult patients undergoing non-contrast computed tomography (NCCT) abdomen examinations. This study aimed to evaluate radiation dose metrics in adult NCCT abdomen examinations with particular emphasis on SSDE and to compare the findings with international diagnostic reference levels. A retrospective analysis of 130 adult patients was performed. CTDIvol and DLP were recorded from scanner-generated dose reports, and effective dose was calculated using standard abdominal conversion coefficients. SSDE was derived using patient anteroposterior and lateral body dimensions based on American Association of Physicists in Medicine TG-204 recommendations. The mean CTDIvol and DLP were 8.59 ± 2.13 mGy and 405.2 ± 121.46 mGy·cm, respectively, with a calculated effective dose of 6.08 ± 1.82 mSv. The mean SSDE was 13.53 ± 3.03 mGy, significantly higher than CTDIvol (p < 0.01). All dose indices were below the American College of Radiology and International Atomic Energy Agency reference levels. The study demonstrates that reliance on CTDIvol significantly underestimates the absorbed radiation dose in adult NCCT abdomen examinations. Incorporating SSDE provides a more accurate, patient-specific estimation of actual radiation dose.

  • Open Access

    Quantitative Assessment of Radiation Dose Reduction Using Aluminum and Copper Beam Filtration in Pediatric Chest Radiography Phantom Study

    by Km Pooja, Rohit Sharma, Sugandhi Sharma, Abhishek Kumar, Anupama Tandon, Atul Mishra

    Children are more radiosensitive than adults, making radiation dose optimization a priority in pediatric radiography. In chest imaging, low-energy photons contribute substantially to patient dose without significantly improving diagnostic information. Additional beam filtration using aluminum (Al) and copper (Cu) can reduce radiation exposure by selectively attenuating low-energy photons; however, standardized comparative data in pediatric chest radiography remain limited. This article quantitatively evaluates radiation dose reduction achieved with aluminum and copper beam filtration during simulated pediatric chest radiography using a phantom-based experimental model. This cross-sectional experimental study was conducted using a 7-cm polymethyl methacrylate phantom representing a pediatric chest. Imaging was performed at 70 kVp and 100 cm source-to-image distance using automatic exposure control. Four filtration conditions were assessed: no additional filtration, 1.0 mm aluminum, 0.1 mm copper, and 0.2 mm copper. Dose area product (DAP) was measured using a calibrated DAP meter. Seven repeated exposures were acquired per condition (total n = 28). Mean DAP and standard deviation were calculated. Statistical analysis was performed using one-way analysis of variance with Tukey's post-hoc testing. The highest mean DAP was observed without additional filtration (0.628 ± 0.005 Gy·cm2). Aluminum filtration (1.0 mm) reduced DAP by 27.2% (0.457 ± 0.008 Gy·cm2). Greater reductions were achieved with copper filtration: 0.1 mm Cu resulted in a 42.5% reduction (0.361 ± 0.005 Gy·cm2), while 0.2 mm Cu produced the greatest reduction of 54.9% (0.283 ± 0.006 Gy·cm2). Differences between groups were statistically significant (p < 0.05). Additional beam filtration significantly reduces radiation dose in simulated pediatric chest radiography, with copper filtration demonstrating superior performance compared to aluminum. Incorporating thin copper filtration, particularly 0.2 mm Cu, into pediatric chest radiography protocols may substantially reduce patient radiation exposure while maintaining standardized detector exposure. These findings support beam filtration as a practical optimization strategy in accordance with the ALARA (as low as reasonably achievable) principles. Clinical implementation should be accompanied by objective image quality evaluation and protocol validation across different pediatric age groups.

  • Open Access

    Comparative Role of Biparametric and Multiparametric MRI in Detection of Muscle Invasive Bladder Cancer Using VI-RADS Scoring System: A Prospective Observational Study

    by Sonu Kaushik, Rohit Sharma, Mahesh Kumar Mittal, Anuradha Sharma, Pawan Vasudeva, Reeta Kanaujiya

    Vesical Imaging–Reporting and Data System (VI-RADS) has been recently proposed for standardizing magnetic resonance imaging (MRI) reporting in bladder cancer. In this single-center prospective observational study, we sought to compare the diagnostic accuracy of biparametric MRI (BP-MRI) and multiparametric MRI (MP-MRI) in detection of detrusor muscle invasion by bladder cancer using VI-RADS. Patients with bladder cancer underwent MRI on a 3 Tesla scanner. Tumors were scored on T2-weighted images (T2WI), diffusion-weighted imaging (DWI), and dynamic contrast enhanced (DCE) imaging according to VI-RADS. Results of BP-MRI and MP-MRI were compared taking histopathology as the gold standard. Receiver operating characteristic (ROC) curve analysis was used to find out the cut-off point of VI-RADS for predicting detrusor muscle invasion by bladder cancer. Diagnostic tests were used to calculate sensitivity and specificity of BP-MRI and MP-MRI for detecting muscle-invasive bladder cancer (MIBC) for each VI-RADS cutoff. A total of 30 patients with bladder cancer were evaluated using MRI. Using the ROC curve, the cut-off for both BP-MRI and MP-MRI VI-RADS for predicting MIBC was determined to be ≥3. Area under the ROC curves (AUROC) of BP-MRI and MP-MRI were 0.866 and 0.861, respectively, the difference being statistically insignificant (DeLong's test p = 0.900). BP-MRI and MP-MRI also had equal sensitivity (95.5%) and specificity (75.0%) at the cut-off of VI-RADS score ≥3. On account of their similar diagnostic accuracy, BP-MRI appears to be a feasible alternative to MP-MRI in detection of detrusor muscle invasion by bladder cancer.

  • Open Access

    Measurement of Scattered Radiation Using Ionization Chamber-Based Survey Meter with Variable Phantom Thickness and Kilovoltage in a Digital Radiographic Room

    by Santosh Yadav, Rohit Sharma, Atul Mishra, A.K. Srivastava, Abhishek Kumar

    Scattered radiation in diagnostic radiology is a source of radiation exposure to medical staff. It mostly originates from patient interaction during X-ray exposure. Its intensity is determined by technical conditions, including kilovoltage (kVp), phantom thickness, and field size. This research endeavors to quantify scatter radiation with an ionization chamber-based survey meter for different conditions of kVp and phantom thickness to assess its effect in a digital radiographic room. A GE Definium XR-8000 digital X-ray machine served as the source of radiation. Scattered radiation at a standard distance and angle was measured with the help of the Fluke 451P ionization chamber-based survey meter. Both a basic water phantom and a general radiographic polymethyl methacrylate phantom were employed with varying thicknesses (5–25 cm and 10–40 mm, respectively). Scattered radiation was measured across different tube voltages (50–125 kVp), while mAs and source-to-image distance were kept constant. Scattered radiation was proportional to both tube voltage and phantom thickness. In 25-cm water phantom thickness, scatter went from 0.38 mR at 50 kVp to 2.05 mR at 125 kVp. A rise in water phantom thickness from 5 to 25 cm at 80 kVp revealed a rise in scatter from 1.67 to 1.9 mR. The radiographic phantom exhibited a similar trend. Present values were higher as compared with values in literature, because the mAs setting was higher for this investigation. This study shows increased scatter with higher kVp and phantom thickness, emphasizing optimized parameters and ALARA (As Low As Reasonably Achievable) for radiation safety.