Akhila Rayampalli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akhila Rayampalli has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Akash Gajanan Prabhune
ADMIRE, IIHMR Bangalore, Bangalore, India
2 shared publications - Vinay R Srihari
ADMIRE, IIHMR Bangalore, Bangalore, India
2 shared publications - Adith Vijay
ADMIRE, IIHMR Bangalore, Bangalore, India
1 shared publication - Subodh S. Satheesh
Department of Hospital and Health Management, Institute of Health Management Research, Bangalore, India
1 shared publication
Latest Publications
- Open Access
FootNet: A Multi-View Smartphone Dataset and Four-Model Benchmark for Clinical Foot Segmentation
We present FootNet, a 453-image multi-view smart-phone foot dataset for binary foot segmentation, with expert-annotated masks across six anatomical views (dorsal, medial, and plantar, both left and right). We benchmark four segmentation models under a controlled protocol: U-Net with a MobileNetV2 encoder achieves the best performance (IoU 0.9268, Dice 0.9608, 95% CI [0.9209, 0.9320]); DeepLabV3 with MobileNetV3-Large scores IoU 0.8984 (Dice 0.9449); UNet++ with MobileNetV2 scores IoU 0.8913 (Dice 0.9391); and SAM ViT-B with oracle bounding-box prompt scores IoU 0.9219 on the matched 191-image sub-set. Bonferroni-corrected Wilcoxon signed-rank tests ( k = 6 comparisons) show U-Net significantly outperforms DeepLab ( p < 0.001, r = 0.638) and SAM ViT-B with oracle bounding-box ( p = 0.005, r = 0.202); UNet++ does not significantly differ from DeepLab ( p = 0.062). Connected-component post-processing yields negligible benefit (mean ΔIoU = +0.0003, 12 of 453 images improved). The extended dataset is available upon request.
Open AccessFootNet: A Multi-View Smartphone Dataset and Four-Model Benchmark for Clinical Foot Segmentation
We present FootNet, a 453-image multi-view smart-phone foot dataset for binary foot segmentation, with expert-annotated masks across six anatomical views (dorsal, medial, and plantar, both left and right). We benchmark four segmentation models under a controlled protocol: U-Net with a MobileNetV2 encoder achieves the best performance (IoU 0.9268, Dice 0.9608, 95% CI [0.9209, 0.9320]); DeepLabV3 with MobileNetV3-Large scores IoU 0.8984 (Dice 0.9449); UNet++ with MobileNetV2 scores IoU 0.8913 (Dice 0.9391); and SAM ViT-B with oracle bounding-box prompt scores IoU 0.9219 on the matched 191-image sub-set. Bonferroni-corrected Wilcoxon signed-rank tests ( k = 6 comparisons) show U-Net significantly outperforms DeepLab ( p < 0.001, r = 0.638) and SAM ViT-B with oracle bounding-box ( p = 0.005, r = 0.202); UNet++ does not significantly differ from DeepLab ( p = 0.062). Connected-component post-processing yields negligible benefit (mean ΔIoU = +0.0003, 12 of 453 images improved). The extended dataset is available upon request.
- Open Access
- 31 January 2026
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 32 (1) , 69-76
Development and Validation of a Predictive AI Framework for Diabetic Foot Ulcer Monitoring and Severity Assessment: A Step towards Self-monitoring and Primary Care Integration
Objectives: Diabetic foot ulcer (DFU) is a critical complication of diabetes that can lead to severe outcomes such as infection, amputation, and increased mortality if left untreated. Early detection and continuous monitoring are essential but remain challenging, especially in resource-limited settings such as India. This study developed and validated a deep learning algorithm to classify diabetic foot images into severity grades based on the International Working Group on the Diabetic Foot classification: grade 0 (healthy), grade 1 (mild), grade 2 (moderate), and grade 3 (severe).Methods: A dataset of 407 clinical images was collected from open-source platforms and clinics in South India and expanded to 612 images through data augmentation. The dataset was divided into training (70%), validation (15%), and testing (15%) subsets. Multiple machine learning models were tested, including MobileNet_V2, EfficientNet-b0, DenseNet121, ResNet_50, VGG16, and ViT_b_16.Results: Among the evaluated models, MobileNet_V2 demonstrated the highest validation accuracy (82%) and achieved an F1-score of 79% on the test set. Although the model showed strong training accuracy, minor overfitting was observed, particularly in distinguishing adjacent severity grades. To address this, dropout, batch normalization, and early stopping were employed. Overall, the model generalized well, showing high accuracy in detecting healthy cases and acceptable performance across ulcer severity grades.Conclusions: This study underscores the potential of machine learning-based tools to support frontline healthcare workers and facilitate patient self-monitoring in low-resource environments. Future work will focus on refining the model and integrating it into user-friendly applications.
- 31 January 2026
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 32 (1) , 69-76
Open AccessDevelopment and Validation of a Predictive AI Framework for Diabetic Foot Ulcer Monitoring and Severity Assessment: A Step towards Self-monitoring and Primary Care Integration
Objectives: Diabetic foot ulcer (DFU) is a critical complication of diabetes that can lead to severe outcomes such as infection, amputation, and increased mortality if left untreated. Early detection and continuous monitoring are essential but remain challenging, especially in resource-limited settings such as India. This study developed and validated a deep learning algorithm to classify diabetic foot images into severity grades based on the International Working Group on the Diabetic Foot classification: grade 0 (healthy), grade 1 (mild), grade 2 (moderate), and grade 3 (severe).Methods: A dataset of 407 clinical images was collected from open-source platforms and clinics in South India and expanded to 612 images through data augmentation. The dataset was divided into training (70%), validation (15%), and testing (15%) subsets. Multiple machine learning models were tested, including MobileNet_V2, EfficientNet-b0, DenseNet121, ResNet_50, VGG16, and ViT_b_16.Results: Among the evaluated models, MobileNet_V2 demonstrated the highest validation accuracy (82%) and achieved an F1-score of 79% on the test set. Although the model showed strong training accuracy, minor overfitting was observed, particularly in distinguishing adjacent severity grades. To address this, dropout, batch normalization, and early stopping were employed. Overall, the model generalized well, showing high accuracy in detecting healthy cases and acceptable performance across ulcer severity grades.Conclusions: This study underscores the potential of machine learning-based tools to support frontline healthcare workers and facilitate patient self-monitoring in low-resource environments. Future work will focus on refining the model and integrating it into user-friendly applications.