Jakob Hufschmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jakob Hufschmidt has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Holl
Division of Medical Physics, Department of Diagnostic and Interventional Radiology University Medical Center Freiburg, Faculty of Medicine, University of Freiburg Freiburg Germany
2 shared publications - Nils Schallner
Department of Anesthesiology and Critical Care Medical Center ‐ University of Freiburg, Faculty of Medicine, University of Freiburg Freiburg Germany
2 shared publications - Sebastian Littin
Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center, University of Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
2 shared publications - Thomas Stieglitz
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
2 shared publications - Cristian Pasluosta
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
1 shared publication - Frank Zijlstra
Department of Radiology and Nuclear Medicine St Olav's University Hospital Trondheim Norway
1 shared publication
Latest Publications
- Open Access
- 9 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3187-3198
Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration
Purpose: Provide the theoretical foundation and the first practical demonstration of spatiotemporal encoding (SPEN) using additional nonlinear gradient hardware. Methods: The quadratic phase profile can be generated either by a chirped‐RF pulse combined with a constant gradient or, directly, by a quadratic gradient pulse. Both a conventional chirped‐RF and a novel SPEN method using a custom‐built matrix gradient coil for quadratic phase generation were implemented and integrated into a spin‐echo echo‐planar‐imaging (SE‐EPI) sequence using Pulseq. The methods were compared through phantom imaging experiments performed on a 3T MRI system. Results: The required quadratic phase profile for SPEN was successfully generated using the nonlinear gradient coil, resulting in images of comparable quality. This quadratic gradient‐based approach was achieved while exploiting the advantages of SPEN and overcoming current SAR and minimal TE limitations arising from the use of chirped‐RF pulses. Conclusion: The generation of the SPEN‐defining quadratic phase using nonlinear gradients is an advantageous alternative to conventional methods. This approach enables improved clinical applicability of SPEN, particularly for 3D and high‐field MRI, by mitigating critical safety and timing limitations. Additionally, an implementation of the conventional method is provided open‐source to support further research.
- 9 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3187-3198
Open AccessSpatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration
Purpose: Provide the theoretical foundation and the first practical demonstration of spatiotemporal encoding (SPEN) using additional nonlinear gradient hardware. Methods: The quadratic phase profile can be generated either by a chirped‐RF pulse combined with a constant gradient or, directly, by a quadratic gradient pulse. Both a conventional chirped‐RF and a novel SPEN method using a custom‐built matrix gradient coil for quadratic phase generation were implemented and integrated into a spin‐echo echo‐planar‐imaging (SE‐EPI) sequence using Pulseq. The methods were compared through phantom imaging experiments performed on a 3T MRI system. Results: The required quadratic phase profile for SPEN was successfully generated using the nonlinear gradient coil, resulting in images of comparable quality. This quadratic gradient‐based approach was achieved while exploiting the advantages of SPEN and overcoming current SAR and minimal TE limitations arising from the use of chirped‐RF pulses. Conclusion: The generation of the SPEN‐defining quadratic phase using nonlinear gradients is an advantageous alternative to conventional methods. This approach enables improved clinical applicability of SPEN, particularly for 3D and high‐field MRI, by mitigating critical safety and timing limitations. Additionally, an implementation of the conventional method is provided open‐source to support further research.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3949-3957
Multiplication of Compound Signals in Neural Array Signal Processing Improves Signal Quality and Detectability of Action Potentials
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3949-3957
Open AccessMultiplication of Compound Signals in Neural Array Signal Processing Improves Signal Quality and Detectability of Action Potentials