VTV. V. Tishchenko

V. V. Tishchenko

*This is an algorithmically generated author record based on publicly available information.

V. V. Tishchenko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simultaneous determination of 12 aminoglycosides in plant products by HPLC-MS/MS after solid-phase extraction

    by A. O. Melekhin, D. P. Bulkatov, A. L. Bairov, M. Yu. Parfenov, A. S. Sherstneva, N. O. Goncharov, V. V. Tishchenko

    A simplified and efficient sample preparation method combined with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed for the determination of twelve aminoglycoside antibiotic pesticides: amikacin, apramycin, validamycin, gentamicin, hygromycin, dihydrostreptomycin, kanamycin, kasugamycin, neomycin, paromomycin, streptomycin, and zhongshengmycin in matrices with high starch content (rice), high acidity (lemon), high fat content (avocado), and high water content (cucumber). The method involves extraction of the compounds with a specific buffer solution consisting of ammonium acetate, EDTA, sodium chloride, and trichloroacetic acid, followed by the extraction of the analytes from the extracts using HLB cartridges. Validation results were satisfactory: the correlation coefficients for the calibration curves (R²) exceeded 0.99 for all target compounds within the linear range across four matrices. Limits of detection (LOD) were 3–15 μg/kg, and limits of quantification (LOQ) were 10–50 μg/kg. Inter-day and intra-day relative standard deviations (RSD) did not exceed 20 %.

  • Open Access

    Simultaneous determination of 14 rodenticides in pathological material by HPLC-MS/MS after purification by solid-phase extraction

    by E. D. Usanova, E. S. Osinova, M. Yu. Parfenov, V. V. Tolmacheva, A. O. Melekhin, V. V. Tishchenko

    A method for determination of rodenticides in pathological material by high-performance liquid chromatography-tandem mass spectrometry is proposed. Various sample preparation methods were compared in the course of developing the methodology. As a result of the comparison, a method that includes liquid extraction using methanol and further purification of the extract by solid-phase extraction on C18 sorbent was selected. The developed technique was validated, the detection limits were 2–5 μg/kg. The relative standard deviation of the analysis results does not exceed 20 %. The matrix effects in the determination did not exceed 25 %.