Emile A. Schweikert
Research Subjects
Emile A. Schweikert has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Yong Nam
Department of Materials Science and Chemical Engineering, Stony Brook University 2 , Stony Brook, New York 11794
2 shared publications - Gregrey Swieca
Department of Chemistry and Biochemistry, University of Mississippi 1 , Oxford, Mississippi 38677
2 shared publications - Markus Langner
Department of Chemistry and Biochemistry, University of Mississippi 1 , Oxford, Mississippi 38677
2 shared publications - Michael J. Eller
Department of Chemistry and Biochemistry, University of Mississippi 1 , Oxford, Mississippi 38677
2 shared publications - Nikhil Tiwale
Center for Functional Nanomaterials, Brookhaven National Laboratory 3 , Upton, New York 11973
2 shared publications - Pierre Hirchenhahn
Department of Chemistry, Texas A&M University , College Station, Texas 77840
2 shared publications
Latest Publications
- 14 August 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Investigation of as-cast polymethylmethacrylate based homopolymer resists in positive ion mode with nano projectile secondary ion mass spectrometry
Polymethylmethacrylate (PMMA) is a positive tone photoresist, which undergoes chain scission under extreme ultraviolet exposure and is often used as a model photoresist for mechanistic studies due to its simplicity. Nano projectile secondary ion mass spectrometry (NP-SIMS) can be used to gain chemical information about the surface composition of a sample. NP-SIMS involves the bombardment of the sample surface with primary ions and the collection of the ejected secondary ions. The primary ions, Au4004+, are separated in time and space, and this enables the analysis of the secondary ions from each individual impact. Thin films (≈25 nm thick) of spin-cast PMMA of different molecular weights (35, 200, 495, and 950 kDa) on the silicon substrate were investigated regarding postincident fragmentation patterns. Three circular areas of 125 μm diameter were analyzed, and a total of 1–1.5 × 106 spectra were taken for each sample.
- 14 August 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Investigation of as-cast polymethylmethacrylate based homopolymer resists in positive ion mode with nano projectile secondary ion mass spectrometry
Polymethylmethacrylate (PMMA) is a positive tone photoresist, which undergoes chain scission under extreme ultraviolet exposure and is often used as a model photoresist for mechanistic studies due to its simplicity. Nano projectile secondary ion mass spectrometry (NP-SIMS) can be used to gain chemical information about the surface composition of a sample. NP-SIMS involves the bombardment of the sample surface with primary ions and the collection of the ejected secondary ions. The primary ions, Au4004+, are separated in time and space, and this enables the analysis of the secondary ions from each individual impact. Thin films (≈25 nm thick) of spin-cast PMMA of different molecular weights (35, 200, 495, and 950 kDa) on the silicon substrate were investigated regarding postincident fragmentation patterns. Three circular areas of 125 μm diameter were analyzed, and a total of 1–1.5 × 106 spectra were taken for each sample.
- 7 August 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Investigation of as-cast polymethylmethacrylate based homopolymer resists in negative ion mode with nano projectile secondary ion mass spectrometry
Polymethylmethacrylate (PMMA) undergoes chain scission under exposure of high-energy photons or electrons, leading to a solubility switch in exposed areas. It is often used as a model photoresist for mechanistic studies due to its chemical and mechanistic simplicity. Nano projectile secondary ion mass spectrometry (NP-SIMS) can be used to gain chemical information about the surface composition of a sample with high lateral resolution. NP-SIMS involves the bombardment of the surface with primary ions, Au4004+ in this case, and the collection of the ejected secondary ions. The separation of the primary ions in time and space enables the analysis of the secondary ions from each individual impact. Thin films (≈25 nm thickness) of spin-cast PMMA of different molecular weights (between 1.3 and 950 kDa) on the silicon substrate were investigated regarding postincident fragmentation patterns. Three circular areas of 125 μm diameter were analyzed and a total of 2–3 × 106 spectra were taken for each sample.
- 7 August 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Investigation of as-cast polymethylmethacrylate based homopolymer resists in negative ion mode with nano projectile secondary ion mass spectrometry
Polymethylmethacrylate (PMMA) undergoes chain scission under exposure of high-energy photons or electrons, leading to a solubility switch in exposed areas. It is often used as a model photoresist for mechanistic studies due to its chemical and mechanistic simplicity. Nano projectile secondary ion mass spectrometry (NP-SIMS) can be used to gain chemical information about the surface composition of a sample with high lateral resolution. NP-SIMS involves the bombardment of the surface with primary ions, Au4004+ in this case, and the collection of the ejected secondary ions. The separation of the primary ions in time and space enables the analysis of the secondary ions from each individual impact. Thin films (≈25 nm thickness) of spin-cast PMMA of different molecular weights (between 1.3 and 950 kDa) on the silicon substrate were investigated regarding postincident fragmentation patterns. Three circular areas of 125 μm diameter were analyzed and a total of 2–3 × 106 spectra were taken for each sample.
- 27 July 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Nanoprojectile-secondary ion mass spectrometry negative spectra of common substrates: Gold and silicon
Gold and silicon are the most common substrates used in surface science, hence the most analyzed with any surface analysis technique. In that regard, SIMS is no exception. Reference spectra have been reported in classical ToF-SIMS with bismuth as the primary projectile. They are not reported using fullerene as the primary projectile. They have also never been reported in the frame of nanoprojectile secondary ion mass spectrometry (NP-SIMS). NP-SIMS involves bombarding the target with individual nanoparticles resolved in space and time, and ultimately recording the secondary ions from each individual impact. The experiments were run on a custom-built ToF-mass spectrometer equipped with a fullerene effusion source. Two different fullerenes were used, C60+ and C60++, accelerated at 25 keV.
- 27 July 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Nanoprojectile-secondary ion mass spectrometry negative spectra of common substrates: Gold and silicon
Gold and silicon are the most common substrates used in surface science, hence the most analyzed with any surface analysis technique. In that regard, SIMS is no exception. Reference spectra have been reported in classical ToF-SIMS with bismuth as the primary projectile. They are not reported using fullerene as the primary projectile. They have also never been reported in the frame of nanoprojectile secondary ion mass spectrometry (NP-SIMS). NP-SIMS involves bombarding the target with individual nanoparticles resolved in space and time, and ultimately recording the secondary ions from each individual impact. The experiments were run on a custom-built ToF-mass spectrometer equipped with a fullerene effusion source. Two different fullerenes were used, C60+ and C60++, accelerated at 25 keV.
- 20 July 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Cholic acid spin-coated with acetone mass spectrum in NP-SIMS in negative mode
Cholic acid is a primary bile acid and is an important biological molecule. Despite its biological importance, it is reported for the first time in nanoprojectile-SIMS (NP-SIMS) and to the best of our knowledge in SIMS in general. The samples were prepared by spin-coating a solution of cholic acid in acetone onto a clean silicon wafer. The spin-coating resulted in a porous surface structure. Mass spectra were acquired by NP-SIMS, which involves bombarding the target with individual nanoparticles resolved in space and time, and ultimately recording the secondary ions from each impact individually. The experiments were run on a custom-built ToF-mass spectrometer equipped with a fullerene effusion source. Fullerene projectiles were accelerated at 25 keV for the mass spectra acquisition. The data presented here encompass the results not specific to NP-SIMS, i.e., the secondary ion distribution, the ion co-emission, and the secondary ion spatial distribution on the detector.
- 20 July 2026
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 33 (2)
Cholic acid spin-coated with acetone mass spectrum in NP-SIMS in negative mode
Cholic acid is a primary bile acid and is an important biological molecule. Despite its biological importance, it is reported for the first time in nanoprojectile-SIMS (NP-SIMS) and to the best of our knowledge in SIMS in general. The samples were prepared by spin-coating a solution of cholic acid in acetone onto a clean silicon wafer. The spin-coating resulted in a porous surface structure. Mass spectra were acquired by NP-SIMS, which involves bombarding the target with individual nanoparticles resolved in space and time, and ultimately recording the secondary ions from each impact individually. The experiments were run on a custom-built ToF-mass spectrometer equipped with a fullerene effusion source. Fullerene projectiles were accelerated at 25 keV for the mass spectra acquisition. The data presented here encompass the results not specific to NP-SIMS, i.e., the secondary ion distribution, the ion co-emission, and the secondary ion spatial distribution on the detector.
- 11 February 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (2)
Secondary ion mass spectrometry in the transmission mode: Update and outlook
Secondary ion mass spectrometry (SIMS) in the transmission mode generates secondary ion yields, which are typically an order of magnitude higher than in the customary reflection setup. The forward emission technique requires ultrathin samples, such as fractions of a monolayer or isolated nanosized objects deposited on substrates like a layer of graphene. We describe the methodology of transmission SIMS and cases of extreme detection sensitivity obtained in bombardment with C60 and Au4004+ of ∼1 keV/atom and Au28008+ of ∼360 eV/atom impact energies.
- 11 February 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (2)
Secondary ion mass spectrometry in the transmission mode: Update and outlook
Secondary ion mass spectrometry (SIMS) in the transmission mode generates secondary ion yields, which are typically an order of magnitude higher than in the customary reflection setup. The forward emission technique requires ultrathin samples, such as fractions of a monolayer or isolated nanosized objects deposited on substrates like a layer of graphene. We describe the methodology of transmission SIMS and cases of extreme detection sensitivity obtained in bombardment with C60 and Au4004+ of ∼1 keV/atom and Au28008+ of ∼360 eV/atom impact energies.