Pierre Kubiak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pierre Kubiak has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrew John Pollard
National Physical Laboratory
1 shared publication - Carmen M. Lopez
Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
1 shared publication - Daniel O’COnnor
National Physical Laboratory
1 shared publication - Giannis Chatzopolous
National Physical Laboratory
1 shared publication - James Marco
University of Warwick
1 shared publication - Ken Mingard
National Physical Laboratory
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by The Electrochemical Society in ECS Advances
- Vol. 5 (3) , 030504
Investigating Formation Cycles in Lithium-Ion Pouch Cells Using in Operando Chromatic Confocal Microscopy
Chromatic Confocal Microscopy (CCM) is an optical, non-contact method that can be used to monitor changes in Lithium-ion cell thickness in operando. Additionally, this method is ideal for quality control of cells as the equipment used is compact and can be deployed in research environments as well as production lines. In this work we demonstrated for the first time a new measurement protocol and mathematical treatment to perform correlative differential analysis (CDA) with cell cycling and CCM data. We investigated the formation cycles of full pouch cells containing NMC 111 positive electrodes and either silicon-carbon blended negative electrodes or carbon-only negative electrodes. A total of eight cells, four for each chemistry, were measured; we discussed the validation of the experimental set-up and the data treatment. The method proved to be good at elucidating aspects of cell formation and an excellent tool for quality control of electrodes as well as for the fabrication of the pouch cells themselves. An unexpected finding, a contraction measured upon first polarizing the cells, was attributed to changes in electrostriction of the specifically absorbed ions primarily due to reorganization of their solvation shells.
- 1 September 2026
- Published by The Electrochemical Society in ECS Advances
- Vol. 5 (3) , 030504
Open AccessInvestigating Formation Cycles in Lithium-Ion Pouch Cells Using in Operando Chromatic Confocal Microscopy
Chromatic Confocal Microscopy (CCM) is an optical, non-contact method that can be used to monitor changes in Lithium-ion cell thickness in operando. Additionally, this method is ideal for quality control of cells as the equipment used is compact and can be deployed in research environments as well as production lines. In this work we demonstrated for the first time a new measurement protocol and mathematical treatment to perform correlative differential analysis (CDA) with cell cycling and CCM data. We investigated the formation cycles of full pouch cells containing NMC 111 positive electrodes and either silicon-carbon blended negative electrodes or carbon-only negative electrodes. A total of eight cells, four for each chemistry, were measured; we discussed the validation of the experimental set-up and the data treatment. The method proved to be good at elucidating aspects of cell formation and an excellent tool for quality control of electrodes as well as for the fabrication of the pouch cells themselves. An unexpected finding, a contraction measured upon first polarizing the cells, was attributed to changes in electrostriction of the specifically absorbed ions primarily due to reorganization of their solvation shells.
- Open Access
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
The Instrumentation and In-situ Gas Pressure Monitoring of Li-ion pouch cells
Internal gas pressure monitoring during lithium-ion battery (LIB) operation is a key area of interest, it has the potential to provide a better in-depth understanding of battery operating status, as it varies with state of charge (SOC), electrical and thermal dynamic loading, and ageing. For the first time, we present a methodology that directly measures the internal gas pressure via a bespoke interphase fitting on different pouch cell variants. This method provides an accurate representation of the internal gas pressure within pouch cells compared to current state-of-the-art methodologies that measure the change in the volume of the pouch bag and do not directly sample the internal gas. This methodology also offers the potential for adaptation for simultaneous gas composition analysis. Initial results from this work highlight the extensive gas generation observed during formation of lithium iron phosphate (LFP)/graphite pouch cells (12 cm x 5 cm) and nickel manganese cobalt (NMC)622/graphite A7 pouch cells. The reversible pressure change due to lithiation/delithiation of the electrodes is also observed with the SOC dependant trends in pressure for both cell chemistries. Our study further highlights the non-linear relationship between gas pressure and temperature under no electrical load and verifies the instrumentation methodology does not have an adverse effect on battery performance.
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Instrumentation and In-situ Gas Pressure Monitoring of Li-ion pouch cells
Internal gas pressure monitoring during lithium-ion battery (LIB) operation is a key area of interest, it has the potential to provide a better in-depth understanding of battery operating status, as it varies with state of charge (SOC), electrical and thermal dynamic loading, and ageing. For the first time, we present a methodology that directly measures the internal gas pressure via a bespoke interphase fitting on different pouch cell variants. This method provides an accurate representation of the internal gas pressure within pouch cells compared to current state-of-the-art methodologies that measure the change in the volume of the pouch bag and do not directly sample the internal gas. This methodology also offers the potential for adaptation for simultaneous gas composition analysis. Initial results from this work highlight the extensive gas generation observed during formation of lithium iron phosphate (LFP)/graphite pouch cells (12 cm x 5 cm) and nickel manganese cobalt (NMC)622/graphite A7 pouch cells. The reversible pressure change due to lithiation/delithiation of the electrodes is also observed with the SOC dependant trends in pressure for both cell chemistries. Our study further highlights the non-linear relationship between gas pressure and temperature under no electrical load and verifies the instrumentation methodology does not have an adverse effect on battery performance.