Gabriela Ananieva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gabriela Ananieva has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Bram Bicknese
Elitac Wearables B.V. Utrecht Netherlands
1 shared publication- Cédric Plesse
LPPI CY Cergy Paris Université Cergy‐Pontoise France
1 shared publication - Cédric Vancaeyzeele
LPPI CY Cergy Paris Université Cergy‐Pontoise France
1 shared publication Felix Dransfeld
Elitac Wearables B.V. Utrecht Netherlands
1 shared publicationFrédéric Vidal
LPPI CY Cergy Paris Université Cergy‐Pontoise France
1 shared publication- Giao Tran Minh Nguyen
LPPI CY Cergy Paris Université Cergy‐Pontoise France
1 shared publication
Latest Publications
- Open Access
Dual‐Functionality, Bio‐Friendly Artificial Muscles for Actuation and Motion Sensing in Smart Wearable Systems
Herein, we report a biofriendly, air‐operating electrochemical platform based on a unipolar coiled carbon nanotube (CNT) yarn artificial muscle that can operate either as an ionic actuator or as an ionotronic strain sensor. The device comprises two coiled CNT yarn electrodes coated with complementary ion‐selective eutectogels, consisting of fixed‐charge polymer networks swollen with a diluted deep eutectic solvent (DES), enabling selective ion transport. Under an applied potential difference, the complementary electrochemical responses of both electrodes produce synchronized unipolar contraction, whereas in sensing mode the device generates a strain‐dependent open‐circuit voltage (OCV) variation. In actuation mode, the device achieves a maximal reversible contractile stroke of 2.9% under a 90 mN pre‐load. In sensing mode, it operates as a self‐powered strain sensor with a sensitivity of 0.5 mV.% −1 . Poisson–Nernst–Planck modelling is consistent with the proposed mechanism of strain‐induced ion redistribution within the quasi‐solid‐state matrix. Two yarn artificial muscles were woven into a custom‐made, bi‐stretch auxetic structure with a folded zigzag geometry, enabling parallel actuation and strain monitoring, delivering peak‐to‐peak OCV signals of 4 mV at 10% extension. Finally, we demonstrate a wireless wearable armband for real‐time motion monitoring, highlighting the potential of this platform for smart fabrics, wearable electronics, and adaptive soft robotics.
Open AccessDual‐Functionality, Bio‐Friendly Artificial Muscles for Actuation and Motion Sensing in Smart Wearable Systems
Herein, we report a biofriendly, air‐operating electrochemical platform based on a unipolar coiled carbon nanotube (CNT) yarn artificial muscle that can operate either as an ionic actuator or as an ionotronic strain sensor. The device comprises two coiled CNT yarn electrodes coated with complementary ion‐selective eutectogels, consisting of fixed‐charge polymer networks swollen with a diluted deep eutectic solvent (DES), enabling selective ion transport. Under an applied potential difference, the complementary electrochemical responses of both electrodes produce synchronized unipolar contraction, whereas in sensing mode the device generates a strain‐dependent open‐circuit voltage (OCV) variation. In actuation mode, the device achieves a maximal reversible contractile stroke of 2.9% under a 90 mN pre‐load. In sensing mode, it operates as a self‐powered strain sensor with a sensitivity of 0.5 mV.% −1 . Poisson–Nernst–Planck modelling is consistent with the proposed mechanism of strain‐induced ion redistribution within the quasi‐solid‐state matrix. Two yarn artificial muscles were woven into a custom‐made, bi‐stretch auxetic structure with a folded zigzag geometry, enabling parallel actuation and strain monitoring, delivering peak‐to‐peak OCV signals of 4 mV at 10% extension. Finally, we demonstrate a wireless wearable armband for real‐time motion monitoring, highlighting the potential of this platform for smart fabrics, wearable electronics, and adaptive soft robotics.
- Open Access
- 16 February 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (6)
Impact of Textile Architecture on the Electromechanical Behavior of Conductive Carbon: Silicone Composite Strain Sensors
Stretchable strain sensors can be used to track motion or biophysical stimuli in a variety of applications, yet their adoption is hindered by complex fabrication processes and unpredictable electromechanical behavior. To overcome this limitation, we have integrated a stretchable carbon black composite consisting of commercially available materials directly onto a textile using stencil printing to realize a strain sensor. We find that the knit structure significantly influences sensor uniformity, dimensional stability, and stretchability, while yarn morphology dictates the hysteresis effect. This is demonstrated using a double weft (1 × 1 rib) and a double warp (tricot) knit. The stitch density of the textile is inversely proportional to the sensor's initial resistance and to the gauge factor, irrespective of the textile's mechanical or chemical properties. This study presents a novel model for estimating nominal resistance at a given strain near the percolation threshold, using solely the textile architecture, which can greatly assist in the development of wearable electronics in textiles.
- 16 February 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (6)
Open AccessImpact of Textile Architecture on the Electromechanical Behavior of Conductive Carbon: Silicone Composite Strain Sensors
Stretchable strain sensors can be used to track motion or biophysical stimuli in a variety of applications, yet their adoption is hindered by complex fabrication processes and unpredictable electromechanical behavior. To overcome this limitation, we have integrated a stretchable carbon black composite consisting of commercially available materials directly onto a textile using stencil printing to realize a strain sensor. We find that the knit structure significantly influences sensor uniformity, dimensional stability, and stretchability, while yarn morphology dictates the hysteresis effect. This is demonstrated using a double weft (1 × 1 rib) and a double warp (tricot) knit. The stitch density of the textile is inversely proportional to the sensor's initial resistance and to the gauge factor, irrespective of the textile's mechanical or chemical properties. This study presents a novel model for estimating nominal resistance at a given strain near the percolation threshold, using solely the textile architecture, which can greatly assist in the development of wearable electronics in textiles.