WZWenjing Zhang

Wenjing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenjing Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Theoretical and Experimental Research on Pirani Vacuum Sensors for In Situ Detection in Near Space

    by Dezhi Zheng, Jinghao Chen, Lijing Han, Minze Chen, Wenfeng Liu, Zhiao Zhu, Wenjing Zhang, Zhongxiang Li, Chun Hu, Weidong Dai

    In this paper, a micro-electromechanical system (MEMS) ultra-low pressure sensor is developed, which is specifically tailored for rocket sounding systems and provides an in-situ detection approach for pressure measurement in the near-space environment. To enhance the overload resistance of the sensor, a composite film consisting of aluminum (Al) film and photosensitive polyimide (PSPI) film is adopted. Meanwhile, its sensitivity is improved by optimizing the structural grooves. The structural parameters of the sensor are determined through theoretical analysis and simulation modeling, and its overload resistance capability is evaluated via ground tests. The test results demonstrate that the sensor has a measurement range of 5 - 6000 Pa, an accuracy higher than 7.73%, and an overload resistance exceeding 200g. Furthermore, actual rocket sounding flight tests confirm that the sensor can effectively withstand the overload impact during rocket launch and successfully detect the air pressure data in the near-space range below 72 km, thus verifying its feasibility as an in-situ pressure detection method for near-space.

  • Fast Response Graphene Foam/MoS 2 -Based Humidity Sensor Based on Data-Driven Dynamic Compensation

    by Yikai Wang, Wenjing Zhang, Chun Hu, Yang Yang, Jinghao Chen, Zhongxiang Li, Dezhi Zheng

    A novel humidity sensor based on graphene foam combined with MoS2 was prepared in this paper. MoS2/graphene foam (MGF) composite materials were synthesized by the atmospheric pressure CVD method, then transferred onto a glass substrate, and had electrodes prepared to complete sensor fabrication. Due to the high surface - to - volume ratio and network structure of sensing materials, humidity sensors exhibit shorter response and recovery times by allowing water molecules to be absorbed and released more quickly. Besides, this type of sensor also shows relatively linear sensitivity (0.04%/%RH between 10% and 90% RH) and good repeatability (the maximum offset within 0.41% at 60% RH), so that it can be used for respiratory monitoring. This provides a unique method for respiratory monitoring that can be applied in medical monitoring, with great potential for use. Moreover, to further enhance the dynamic performance of humidity sensors, a dynamic compensation method combined with system identification and particle swarm optimization (PSO) is proposed. By employing this approach, the identified dynamic mathematical model agrees well with the actual measurement results (95.67% in absorption and 91.09% in desorption). In the process of moisture absorption, the sensor component's operational bandwidth is enhanced from 0.06 Hz to 1.91 Hz, and the response time is shortened from 2.06s to 0.29s. During desorption, the sensor component's operational bandwidth is enhanced from 0.02 Hz to 1.75 Hz, and the recovery time is shortened from 3.74s to 0.48s. This dynamic compensation method offers a practical approach to enhance these sensors' performance.