ZXZhiqiang Xia

Zhiqiang Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiqiang Xia has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Chi Li

    Laboratory of Nanophotonic Materials and Devices, Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China

    1 shared publication
  • Liye Zhao

    School of Instrument Science and Engineering, Southeast University, Nanjing, China

    1 shared publication
  • Shichao Feng

    China Ship Scientific Research Center, Wuxi 214082, China

    1 shared publication
  • Xiaodong Sun

    Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology, Ministry of Education, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China

    1 shared publication
  • Zhenjun Li

    CAS Key Laboratory of Nanophotonic Materials and Devices (Preparatory), National Center for Nanoscience and Technology, Beijing 100190, China

    1 shared publication

Latest Publications

  • Open Access

    Thermal-Assisted Field Emission Characteristics of Carbon Nanotubes and Application in Pulsed X-Ray Imaging

    by Zhiqiang Xia, Shichao Feng, Xiaodong Sun, Chi Li, Zhenjun Li, Liye Zhao

    Carbon nanotube (CNT) cathode materials exhibit excellent electron emission performance and have become a key research focus in the field of vacuum electronics. However, their practical applications are still restricted by challenges, including emission instability and ambiguity in temporal resolution capability. This work investigated the thermal-assisted field emission characteristics of CNT and their application in pulsed X-ray imaging. Systematic characterization of the turn-on field strength, emission stability, pulse response characteristics, and pulsed X-ray imaging performance demonstrated that the thermal-assisted operating mode reduced current fluctuations to below 1%. Increasing the heating power further enhanced emission stability and lowered the turn-on field strength. In thermal-assisted pulsed emission mode, CNT cathodes exhibited reduced power consumption compared to conventional thermionic cathodes and achieved microsecond-scale pulse response. Further X-ray imaging experiments confirmed that the X-ray dose generated by CNT in this operational mode exhibited higher stability, enabling 100 μs pulsed imaging and clear visualization of rotating blades operating at 600 Hz. This study validated the feasibility of CNT cathodes for high-speed X-ray imaging and could provide a reference for the development of advanced pulsed X-ray sources and related technologies.