Zdeňka Čermáková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zdeňka Čermáková has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Janka Hradilová
Academy of Fine Arts in Prague, ALMA laboratory, U Akademie 4, 170 22 Prague 7, Czech Republic
2 shared publications- Petr Bezdička
Institute of Inorganic Chemistry of the Czech Academy of Sciences, Husinec-Řež 1001, 250 68 Řež, Czech Republic
2 shared publications - Silvie Švarcová
Institute of Inorganic Chemistry of the Czech Academy of Sciences, Husinec 1001, 250 68 Husinec-Řež, Czech Republic
2 shared publications - Adriana Lančok
Institute of Inorganic Chemistry AS CR, v. v. i., 250 68 Husinec-Řež 1001, Czech Republic
1 shared publication - Dalibor Valik
Department of Laboratory Medicine, Masaryk University and University Hospital Brno, 62500 Brno, Czech Republic
1 shared publication David Hradil
Institute of Inorganic Chemistry of the AS CR, v.v.i., ALMA Laboratory & Laboratory of Low Temperatures, Husinec-Řež 1001, 250 68 Řež, Czech Republic; Academy of Fine Arts in Prague, ALMA Laboratory, U Akademie 4, 170 22 Prague 7, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 20 October 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (3) , 1805-1809
Interpretive discrepancies caused by target values inter‐batch variations in chemiluminescence immunoassay for SARS‐CoV‐2 IgM/IgG by MAGLUMI
Plasma specimens from coronavirus disease 2019 patients were double‐tested for anti‐severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) antibodies by two different batches of MAGLUMI 2019‐nCov immunoglobulin M/immunoglobulin G (IgM/IgG) assays to evaluate IgM/IgG levels, qualitative interpretation, antibody kinetics, and linearity of diluted specimen. Here we show that (i) high‐level IgM specimens need to be diluted with negative human plasma but not kit diluents and (ii) measured anti‐SARS‐CoV‐2 IgM/IgG concentrations are substantially higher with later marketed immunoassay batch leading to (iii) the change of qualitative interpretation (positive vs. negative) in 12.3% of specimens measured for IgM, (iv) the informative time‐course pattern of antibody production only when data from different immunoassay batches are not combined.
- 20 October 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (3) , 1805-1809
Open AccessInterpretive discrepancies caused by target values inter‐batch variations in chemiluminescence immunoassay for SARS‐CoV‐2 IgM/IgG by MAGLUMI
Plasma specimens from coronavirus disease 2019 patients were double‐tested for anti‐severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) antibodies by two different batches of MAGLUMI 2019‐nCov immunoglobulin M/immunoglobulin G (IgM/IgG) assays to evaluate IgM/IgG levels, qualitative interpretation, antibody kinetics, and linearity of diluted specimen. Here we show that (i) high‐level IgM specimens need to be diluted with negative human plasma but not kit diluents and (ii) measured anti‐SARS‐CoV‐2 IgM/IgG concentrations are substantially higher with later marketed immunoassay batch leading to (iii) the change of qualitative interpretation (positive vs. negative) in 12.3% of specimens measured for IgM, (iv) the informative time‐course pattern of antibody production only when data from different immunoassay batches are not combined.
- 1 April 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 140, 101-110
Temperature-related degradation and colour changes of historic paintings containing vivianite
- 1 April 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 140, 101-110
Temperature-related degradation and colour changes of historic paintings containing vivianite
- 22 July 2014
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 45 (9) , 848-858
Crocoite PbCrO4 and mimetite Pb5(AsO4)3Cl: rare minerals in highly degraded mediaeval murals in Northern Bohemia
Mural paintings of exceptional quality, which can be discerned in spite of their extensive mechanical damage and colour fading, have been uncovered in the church of St. Gallus in Kuřívody, Northern Bohemia, dated to the second half of the 13th century. Materials research with particular use of portable X‐ray fluorescence, Raman micro‐spectroscopy and powder X‐ray micro‐diffraction revealed the presence of rare pigments. In Kuřívody, it is only a second identification of intentionally used yellow mineral crocoite (PbCrO4) in European art. Its identification is facilitated by providing a very good Raman scattering, even when present in small amounts in fragmentarily preserved colour layers. Light yellow mimetite (Pb5(AsO4)3Cl) was never before mentioned as intentionally used pigment in Europe. Its finding in Kuřívody, however, corresponds more likely with undesirable physical–chemical conditions causing its formation by alteration of orpiment (As2S3) and minium (Pb3O4). Obtained results highlight the importance of Raman spectroscopy for direct identification of mineral pigments in low concentrations, which may be crucial for interpreting cultural heritage objects in historical context. By materials, the almost forgotten paintings in Kuřívody can be seen as outstanding and rare example of ancient artistic tradition that has spread to Europe from Mediterranean in early Middle Ages. After all, mineral crocoite was already used by ancient Egyptians to paint sarcophagi and degraded orpiment decorates the walls of the Nefertari's tomb in Thebes. Copyright © 2014 John Wiley & Sons, Ltd.
- 22 July 2014
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 45 (9) , 848-858
Crocoite PbCrO4 and mimetite Pb5(AsO4)3Cl: rare minerals in highly degraded mediaeval murals in Northern Bohemia
Mural paintings of exceptional quality, which can be discerned in spite of their extensive mechanical damage and colour fading, have been uncovered in the church of St. Gallus in Kuřívody, Northern Bohemia, dated to the second half of the 13th century. Materials research with particular use of portable X‐ray fluorescence, Raman micro‐spectroscopy and powder X‐ray micro‐diffraction revealed the presence of rare pigments. In Kuřívody, it is only a second identification of intentionally used yellow mineral crocoite (PbCrO4) in European art. Its identification is facilitated by providing a very good Raman scattering, even when present in small amounts in fragmentarily preserved colour layers. Light yellow mimetite (Pb5(AsO4)3Cl) was never before mentioned as intentionally used pigment in Europe. Its finding in Kuřívody, however, corresponds more likely with undesirable physical–chemical conditions causing its formation by alteration of orpiment (As2S3) and minium (Pb3O4). Obtained results highlight the importance of Raman spectroscopy for direct identification of mineral pigments in low concentrations, which may be crucial for interpreting cultural heritage objects in historical context. By materials, the almost forgotten paintings in Kuřívody can be seen as outstanding and rare example of ancient artistic tradition that has spread to Europe from Mediterranean in early Middle Ages. After all, mineral crocoite was already used by ancient Egyptians to paint sarcophagi and degraded orpiment decorates the walls of the Nefertari's tomb in Thebes. Copyright © 2014 John Wiley & Sons, Ltd.
- 17 September 2013
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 51 (1) , 110-113
Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory
Background: The present study was aimed at determining the effect of the tube type used for primary sample collection and the manner of transport prior to assessment (either manual or by pneumatic tube) on the degree of pseudohyperkalaemia in leukaemic patients. Methods: Blood from six leukaemic patients was collected into seven primary sample tubes (Monovette®, Sarstedt): sample A, heparinized blood gas syringe (potassium reference value); sample B, plasma Li-heparin without separator gel; sample C, plasma Li-heparin with separator gel; and sample D, serum with separator gel. The primary sample tubes designated B, C and D were transported to the laboratory manually. Duplicates of the same sample tubes, B PT , C PT and D PT , were sent to the laboratory by pneumatic tube. Results: In patients with chronic lymphocytic leukaemia (CLL), there was no increase in the concentration of potassium in samples B, C and D when compared to the reference value. Transport of the samples by pneumatic tube led to a pronounced increase in potassium concentration in samples B PT and C PT , whereas there was no increase in sample D PT when compared to the reference value. In the patient with chronic myeloid leukaemia (CML), an increase in potassium concentration occurred in sample D and in samples B PT , C PT and D PT . A similar finding was observed in the patient with acute lymphocytic leukaemia (ALL), furthermore with an extremely high concentration of potassium in samples C and C PT . Conclusions: Manual transport of non-coagulable blood (plasma Li-heparin without separator gel) to the laboratory results in the least possible artificial increase in potassium concentration in the sample.
- 17 September 2013
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 51 (1) , 110-113
Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory
Background: The present study was aimed at determining the effect of the tube type used for primary sample collection and the manner of transport prior to assessment (either manual or by pneumatic tube) on the degree of pseudohyperkalaemia in leukaemic patients. Methods: Blood from six leukaemic patients was collected into seven primary sample tubes (Monovette®, Sarstedt): sample A, heparinized blood gas syringe (potassium reference value); sample B, plasma Li-heparin without separator gel; sample C, plasma Li-heparin with separator gel; and sample D, serum with separator gel. The primary sample tubes designated B, C and D were transported to the laboratory manually. Duplicates of the same sample tubes, B PT , C PT and D PT , were sent to the laboratory by pneumatic tube. Results: In patients with chronic lymphocytic leukaemia (CLL), there was no increase in the concentration of potassium in samples B, C and D when compared to the reference value. Transport of the samples by pneumatic tube led to a pronounced increase in potassium concentration in samples B PT and C PT , whereas there was no increase in sample D PT when compared to the reference value. In the patient with chronic myeloid leukaemia (CML), an increase in potassium concentration occurred in sample D and in samples B PT , C PT and D PT . A similar finding was observed in the patient with acute lymphocytic leukaemia (ALL), furthermore with an extremely high concentration of potassium in samples C and C PT . Conclusions: Manual transport of non-coagulable blood (plasma Li-heparin without separator gel) to the laboratory results in the least possible artificial increase in potassium concentration in the sample.