UCUmberto Crimaldi

Umberto Crimaldi

*This is an algorithmically generated author record based on publicly available information.

Umberto Crimaldi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Giovanni Mettivier

    Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, I-80126 Napoli, Italy; Dipartimento di Fisica "Ettore Pancini", Università di Napoli Federico II, I-80126 Napoli, Italy

    2 shared publications
  • Laura Antonia Cerbone

    Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, I-80126 Napoli, Italy; Scuola Superiore Meridionale, I-80138 Napoli, Italy; Dipartimento di Fisica "Ettore Pancini", Università di Napoli Federico II, I-80126 Napoli, Italy

    2 shared publications
  • Nastassja Luongo

    Azienza Ospedaliera Universitaria Policlinico Federico II, I-80131 Napoli, Italy

    2 shared publications
  • Paolo Russo

    Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, I-80126 Napoli, Italy; Dipartimento di Fisica "Ettore Pancini", Università di Napoli Federico II, I-80126 Napoli, Italy

    2 shared publications
  • Roberto Pacelli

    Department of Cardiovascular Sciences, Diagnostic Imaging and Time-Dependent Network of Cardiovascular Emergencies, University Hospital “Federico II”, Via Pansini, 80128 Napoli, Italy

    2 shared publications

Latest Publications

  • Open Access

    Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy

    by Umberto Crimaldi, Nastassja Luongo, Laura Antonia Cerbone, Roberto Pacelli, Paolo Russo, Giovanni Mettivier

    Spatially fractionated radiotherapy with X-ray minibeams (x-MBRT) aims to increase normal-tissue tolerance by delivering alternating high- and low-dose regions. We provide a Monte Carlo-based framework to design and optimize multi-slit collimators, quantifying how geometry and material govern peak–valley modulation. A validated digital twin of the SmART X-RAD225Cx irradiator was implemented in TOPAS/Geant4. Various x-MBRT collimators were simulated with parallel or divergent slits. The parameter space covered a slit width w (0.1–0.9 mm), center-to-center spacing CTC (1–3 mm), thickness T (1–5 mm), and acceptance angle θ. Dose was scored in a 2 × 2 × 2 cm3 water phantom at a 1 cm depth. For fixed w/CTC, peak-valley dose ratio PVDR increases with larger CTC via an increase in peak dose, with the valley dose nearly constant. Peak transmission saturated at θ ≈ 3°, indicating minimal benefit from larger acceptance. Divergent slits yielded flatter lateral profiles but higher valley doses than parallel slits, reducing PVDR around the central axis. This Monte Carlo study provides insights for optimizing collimator geometries in x-MBRT using small-animal irradiators, informing the design of more effective collimation systems to enhance treatment precision and normal-tissue sparing.

  • Open Access

    Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy

    by Umberto Crimaldi, Nastassja Luongo, Laura A. Cerbone, Roberto Pacelli, Paolo Russo, Giovanni Mettivier

    Spatially fractionated radiotherapy with X ray minibeams (x MBRT) aims to increase normal tissue tolerance by delivering alternating high and low dose regions. We provide a Monte Carlo–based framework to design and optimize multislit collimators, quantifying how geometry and material govern peak–valley modulation. A validated digital twin of the SmART X RAD225Cx irradiator was implemented in TOPAS/Geant4. Various x-MBRT collimators were simulated with parallel or divergent slits. The parameter space covered slit width w (0.1–0.9 mm), center to center spacing CTC (1–3 mm), thickness T (1–5 mm), and acceptance angle θ. Dose was scored in a 2 × 2 × 2 cm³ water phantom at 1 cm depth. The valley dose increased linearly with the filling factor (w/CTC) and as ~T². For fixed w/CTC, PVDR increases with larger CTC via an increase of peak dose, with valley dose nearly constant. Peak transmission saturated at θ ≈ 3°, indicating minimal benefit from larger acceptance. Divergent slits yielded flatter lateral profiles but higher valley doses than parallel slits, reducing PVDR around the central axis. This Monte Carlo study provides insights for optimizing collimator geometries in x-MBRT using small-animal irradiators, informing the design of more effective collimation systems to enhance treatment precision and normal tissue sparing.