Yunfei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yunfei Wang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ming Lei
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
2 shared publications - Haolan Zeng
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, 611756, People’s Republic of China
1 shared publication - Miao Xu
Chengdu No.7-Yingcai School, Chengdu, 610000, People’s Republic of China
1 shared publication - Xinyu Zuo
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, 611756, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 3 April 2026
- Published by Elsevier in SSRN Electronic Journal
Rapid Extraction Scheme for Dynamic Impedance of Lithium-Ion Batteries Based on a Short-Duration Binary Sequence
Fast and accurate electrochemical impedance spectroscopy measurement is important for state monitoring and fault diagnosis of lithium-ion batteries. Existing methods based on broadband excitation signals can reduce the test time. However, their time-domain sequences are usually complex. This increases the difficulty of hardware implementation and limits their use in high-current measurement scenarios. To address this issue, this paper proposes a rapid extraction method for the dynamic impedance of lithium-ion batteries based on a short-duration binary sequence. A short-duration binary sequence is applied during the battery charge and discharge process. Combined with a second-moment-based impedance extraction algorithm, the method enables real-time and accurate acquisition of dynamic impedance. An interface converter is then used to verify the effectiveness of the proposed method under high-current operating conditions. The results are also compared with quasi-steady-state electrochemical impedance spectra. Experimental results show that the Kramers–Kronig residuals of the dynamic impedance spectra obtained by the proposed method are lower than ±0.5%. In addition, the time-domain length of the excitation sequence is only one-eighth of that required by conventional methods. Theoretical analysis further shows that dynamic operating conditions have little influence on the impedance in the 700 Hz to 1 kHz frequency range. Therefore, a temperature estimation model built from quasi-steady-state impedance in this frequency range can be directly transferred to dynamic conditions. Its estimation error is less than 1.74 °C. These results indicate that the proposed method can provide theoretical support for the online application of dynamic impedance.
- 3 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRapid Extraction Scheme for Dynamic Impedance of Lithium-Ion Batteries Based on a Short-Duration Binary Sequence
Fast and accurate electrochemical impedance spectroscopy measurement is important for state monitoring and fault diagnosis of lithium-ion batteries. Existing methods based on broadband excitation signals can reduce the test time. However, their time-domain sequences are usually complex. This increases the difficulty of hardware implementation and limits their use in high-current measurement scenarios. To address this issue, this paper proposes a rapid extraction method for the dynamic impedance of lithium-ion batteries based on a short-duration binary sequence. A short-duration binary sequence is applied during the battery charge and discharge process. Combined with a second-moment-based impedance extraction algorithm, the method enables real-time and accurate acquisition of dynamic impedance. An interface converter is then used to verify the effectiveness of the proposed method under high-current operating conditions. The results are also compared with quasi-steady-state electrochemical impedance spectra. Experimental results show that the Kramers–Kronig residuals of the dynamic impedance spectra obtained by the proposed method are lower than ±0.5%. In addition, the time-domain length of the excitation sequence is only one-eighth of that required by conventional methods. Theoretical analysis further shows that dynamic operating conditions have little influence on the impedance in the 700 Hz to 1 kHz frequency range. Therefore, a temperature estimation model built from quasi-steady-state impedance in this frequency range can be directly transferred to dynamic conditions. Its estimation error is less than 1.74 °C. These results indicate that the proposed method can provide theoretical support for the online application of dynamic impedance.
- 13 March 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (5) , 050522
A Fractional-Order Model-Based Method for Co-Estimating State-of-Charge and Core Temperature in Lithium-Ion Batteries
Accurate real-time estimation of a battery’s state of charge (SOC) and internal temperature is essential for improving the safety and reliability of battery systems. However, these states are difficult to measure directly in real time. To address this challenge, this paper develops a fractional-order electrothermal coupled model and integrates it with an extended Kalman filter (EKF) to jointly estimate SOC and internal temperature without additional sensors. Experimental results under various operating conditions show that the SOC estimation error is within ±0.01 and the internal temperature error is within ±2 °C. These results demonstrate the effectiveness and feasibility of the proposed joint estimation method.
- 13 March 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (5) , 050522
A Fractional-Order Model-Based Method for Co-Estimating State-of-Charge and Core Temperature in Lithium-Ion Batteries
Accurate real-time estimation of a battery’s state of charge (SOC) and internal temperature is essential for improving the safety and reliability of battery systems. However, these states are difficult to measure directly in real time. To address this challenge, this paper develops a fractional-order electrothermal coupled model and integrates it with an extended Kalman filter (EKF) to jointly estimate SOC and internal temperature without additional sensors. Experimental results under various operating conditions show that the SOC estimation error is within ±0.01 and the internal temperature error is within ±2 °C. These results demonstrate the effectiveness and feasibility of the proposed joint estimation method.