Jie Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Xie has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Haiyang Jiang
State Key Laboratory of Veterinary Public Health and Safety, Department of Veterinary Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
2 shared publications - Sihan Wang
Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
2 shared publications Boyan Sun
State Key Laboratory of Veterinary Public Health and Safety, Key Laboratory for Detection of Veterinary Drug Residues and Illegal Additives of Ministry of Agriculture and Rural Affairs, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
1 shared publication- Boyan Sun
State Key Laboratory of Veterinary Public Health and Safety, Department of Veterinary Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
1 shared publication Chujun Liu
State Key Laboratory of Veterinary Public Health and Safety, Key Laboratory for Detection of Veterinary Drug Residues and Illegal Additives of Ministry of Agriculture and Rural Affairs, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
1 shared publication- Chujun Liu
State Key Laboratory of Veterinary Public Health and Safety, Department of Veterinary Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
1 shared publication
Latest Publications
- 22 April 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (21) , 4363-4374
Development and validation of an LC-MS/MS/MS method for the sensitive quantification of trace β-agonists in complex animal-derived food matrices
The LC-MS 3 method, which overcomes matrix interference and enhances selectivity, sensitivity, and specificity through its multi-stage fragmentation capabilities, was first applied to simultaneously quantify nine β-agonists in high-fat milk and pork.
- 22 April 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (21) , 4363-4374
Development and validation of an LC-MS/MS/MS method for the sensitive quantification of trace β-agonists in complex animal-derived food matrices
The LC-MS 3 method, which overcomes matrix interference and enhances selectivity, sensitivity, and specificity through its multi-stage fragmentation capabilities, was first applied to simultaneously quantify nine β-agonists in high-fat milk and pork.
- Open Access
- 26 February 2026
- Published by MDPI AG in Agriculture
- Vol. 16 (5) , 519
Efficient Determination of β-Agonists in Environmental Water and Animal-Derived Matrices by NH2-UiO-66 Based d-SPE Coupled with UPLC-MS/MS: Performance, Mechanism and Application
β-agonists are prohibited antibiotics that have raised concerns due to their illegal use in the livestock industry, posing potential toxicity risks to human health. For ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) analysis of β-agonists, effective sample pretreatment is a crucial and challenging process that dictates the overall reliability and sensitivity of the method. Thus, this study developed a reliable method utilizing dispersive solid-phase extraction (d-SPE) with NH2-UiO-66 as a superior adsorbent, coupled with UPLC-MS/MS, to extract and quantify β-agonists in environmental water, swine urine, and milk. The synthesized NH2-UiO-66 exhibited outstanding adsorption capacities (146.06–358.00 mg/g) towards the target analytes. The optimized method demonstrated excellent performance: low matrix effects (−13.10–15.30%), wide linearity (0.1–50 μg/L), low limits of detection (0.04–0.09 μg/L), and satisfactory recoveries (81.48–106.67%) with good precision (intra-day RSDs 1.51–6.24%; inter-day RSDs 2.06–10.96%). Adsorption mechanism studies revealed that the extraction process, which followed the Langmuir isotherm and pseudo-second-order kinetic models, was driven primarily by electrostatic interactions, π-π stacking, and hydrogen bonding. Moreover, the material could be reused up to 10 times, with satisfactory recoveries of 81.30% to 116.10%. The proposed NH2-UiO-66-d-SPE-UPLC-MS/MS protocol is generic and provides a robust and practical solution for monitoring trace β-agonists in animal-derived foods and environmental samples, ensuring food safety and environmental health.
- 26 February 2026
- Published by MDPI AG in Agriculture
- Vol. 16 (5) , 519
Open AccessEfficient Determination of β-Agonists in Environmental Water and Animal-Derived Matrices by NH2-UiO-66 Based d-SPE Coupled with UPLC-MS/MS: Performance, Mechanism and Application
β-agonists are prohibited antibiotics that have raised concerns due to their illegal use in the livestock industry, posing potential toxicity risks to human health. For ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) analysis of β-agonists, effective sample pretreatment is a crucial and challenging process that dictates the overall reliability and sensitivity of the method. Thus, this study developed a reliable method utilizing dispersive solid-phase extraction (d-SPE) with NH2-UiO-66 as a superior adsorbent, coupled with UPLC-MS/MS, to extract and quantify β-agonists in environmental water, swine urine, and milk. The synthesized NH2-UiO-66 exhibited outstanding adsorption capacities (146.06–358.00 mg/g) towards the target analytes. The optimized method demonstrated excellent performance: low matrix effects (−13.10–15.30%), wide linearity (0.1–50 μg/L), low limits of detection (0.04–0.09 μg/L), and satisfactory recoveries (81.48–106.67%) with good precision (intra-day RSDs 1.51–6.24%; inter-day RSDs 2.06–10.96%). Adsorption mechanism studies revealed that the extraction process, which followed the Langmuir isotherm and pseudo-second-order kinetic models, was driven primarily by electrostatic interactions, π-π stacking, and hydrogen bonding. Moreover, the material could be reused up to 10 times, with satisfactory recoveries of 81.30% to 116.10%. The proposed NH2-UiO-66-d-SPE-UPLC-MS/MS protocol is generic and provides a robust and practical solution for monitoring trace β-agonists in animal-derived foods and environmental samples, ensuring food safety and environmental health.