Lyam M. Bailey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lyam M. Bailey has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Clara Knox
Department of Physics & Atmospheric Science, Dalhousie University, Halifax, NS B3H 4R2, Canada
2 shared publications - Timothy Bardouille
Department of Physics & Atmospheric Science, Dalhousie University, Halifax, Canada
2 shared publications Margot J Taylor
Hospital for Sick Children
1 shared publicationMatthew J Brookes
University of Nottingham
1 shared publicationNatalie Rhodes
Hospital for Sick Children
1 shared publicationRobert A Seymour
University of Oxford
1 shared publication
Latest Publications
- Open Access
OPM-MEG reveals protracted maturation of visual phase-amplitude coupling from early childhood to adulthood
Cross-frequency coupling describes interactions between neural ensembles operating at different frequency bands, and has been proposed to underlie coordination of brain activity over multiple temporal and spatial scales. Phase amplitude coupling (PAC) describes modulation of the amplitude of high-frequency oscillations by the phase of low frequency oscillations. MEG work in adults has demonstrated that alpha-gamma PAC may support visual perception. However, very little work has investigated visual PAC in children, or the development of this process between childhood and adulthood. Here we investigated the development of PAC in a sample of 101 individuals, comprising 50 children (aged 2-13 years) and 51 adults (21-34 years). Participants completed a passive visual stimulation paradigm while neural responses were recorded using a wearable whole-head OPM-MEG system. Sensor-level data were spatially resolved to visual cortex, and we quantified coupling between the phase of low-frequency oscillations (5-13 Hz) and the amplitude of broadband gamma oscillations (28-100 Hz) in each participant. In the adult data, we identified a cluster of phase-amplitude frequency pairs (phase: 7-11 Hz, amplitude: 52-66 Hz) in which there was strong evidence for an increase in PAC following stimulus presentation relative to baseline. Within this cluster, the magnitude of stimulus-induced PAC was positively correlated with age across all participants. Meanwhile, we did not see credible evidence for visual PAC at any frequency pair(s) within the child group. These results suggest that, alongside well-documented developmental changes in band-specific oscillatory power and connectivity, visual PAC represents a distinct functional process which matures with age.
Open AccessOPM-MEG reveals protracted maturation of visual phase-amplitude coupling from early childhood to adulthood
Cross-frequency coupling describes interactions between neural ensembles operating at different frequency bands, and has been proposed to underlie coordination of brain activity over multiple temporal and spatial scales. Phase amplitude coupling (PAC) describes modulation of the amplitude of high-frequency oscillations by the phase of low frequency oscillations. MEG work in adults has demonstrated that alpha-gamma PAC may support visual perception. However, very little work has investigated visual PAC in children, or the development of this process between childhood and adulthood. Here we investigated the development of PAC in a sample of 101 individuals, comprising 50 children (aged 2-13 years) and 51 adults (21-34 years). Participants completed a passive visual stimulation paradigm while neural responses were recorded using a wearable whole-head OPM-MEG system. Sensor-level data were spatially resolved to visual cortex, and we quantified coupling between the phase of low-frequency oscillations (5-13 Hz) and the amplitude of broadband gamma oscillations (28-100 Hz) in each participant. In the adult data, we identified a cluster of phase-amplitude frequency pairs (phase: 7-11 Hz, amplitude: 52-66 Hz) in which there was strong evidence for an increase in PAC following stimulus presentation relative to baseline. Within this cluster, the magnitude of stimulus-induced PAC was positively correlated with age across all participants. Meanwhile, we did not see credible evidence for visual PAC at any frequency pair(s) within the child group. These results suggest that, alongside well-documented developmental changes in band-specific oscillatory power and connectivity, visual PAC represents a distinct functional process which matures with age.
- Open Access
Neuromagnetism “On the Cheap”: Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically shielded rooms to reduce external electromagnetic noise and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor coverage. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs, comprising N20m, P35m and P60m components) and event-related (de)synchronization (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.
Open AccessNeuromagnetism “On the Cheap”: Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically shielded rooms to reduce external electromagnetic noise and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor coverage. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs, comprising N20m, P35m and P60m components) and event-related (de)synchronization (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.
- Open Access
- 27 February 2026
- Published by MDPI AG in Preprints.org
Neuromagnetism “On the Cheap”: Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically-shielded rooms to reduce external electro-magnetic noise, and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor cover-age. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs; comprising N20m, P35m and P60m components) and event-related (de)synchronisation (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.
- 27 February 2026
- Published by MDPI AG in Preprints.org
Open AccessNeuromagnetism “On the Cheap”: Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically-shielded rooms to reduce external electro-magnetic noise, and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor cover-age. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs; comprising N20m, P35m and P60m components) and event-related (de)synchronisation (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.