Dan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dan Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xian Zhou
University of Science and Technology Beijing
3 shared publications - Fei Liu
University of Science and Technology Beijing
2 shared publications - Zhi Wang
University of Science and Technology Beijing
2 shared publications - Ziyi Xu2 shared publications
Fei Cui
University of Science and Technology Beijing
1 shared publicationFei Liu
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (5) , 7101110
Range-Adaptive Wavelength Calibration Fusion Method for Enhanced Demodulation Precision of Optical Frequency Domain Reflectometry
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (5) , 7101110
Open AccessRange-Adaptive Wavelength Calibration Fusion Method for Enhanced Demodulation Precision of Optical Frequency Domain Reflectometry
- Open Access
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Millimeter-Resolution Distributed Fiber-Optic Thermal Imaging for Hotspot and Consistency Diagnosis in Sodium-Ion Batteries
This study develops a millimeter-resolution distributed temperature-sensing platform using all-grating fiber (AGF)-assisted optical frequency domain reflectometry (OFDR) for research and development (R&D) sodium-ion batteries (SIBs). The system achieved a 1.28 mm of sensing spatial resolution, with ~13.16 pm/pm/°C of uniform temperature sensitivity, 0.149°C of uniform temperature precision, and 99.45% of the highest linearity. It successfully visualized dynamic hotspot migration on R&D pouch SIBs, identifying localized hotspots and thermal gradients that were undetectable by point sensors. Compared with conventional thermocouples (TCs), the proposed distributed temperature sensing method successfully reveals an additional 1.88 °C in the maximum surface temperature difference () during the discharging. When applied to a two-cell R&D SIBs module, the method can be employed to diagnose inter-cell thermal inconsistency. As the related results, the two cells exhibited distinctly different NUT trends starting as early as 30% DoD. Furthermore, Cell A illustrated a of 3.63°C and a faster decaying a normalized uniformity temperature (NUT) index of 0.11 at the final moment. Compared to Cell A, the Cell B shown the lower values at 2.56 °C with a final NUT index of 0.2. These relative comparisons suggested weaker thermal stability and higher dead sodium risk of Cell A than Cell B. Hence, this method can be demonstrated as a useful approach for high-resolution SIB thermal diagnosis and consistency screening in batteries.
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMillimeter-Resolution Distributed Fiber-Optic Thermal Imaging for Hotspot and Consistency Diagnosis in Sodium-Ion Batteries
This study develops a millimeter-resolution distributed temperature-sensing platform using all-grating fiber (AGF)-assisted optical frequency domain reflectometry (OFDR) for research and development (R&D) sodium-ion batteries (SIBs). The system achieved a 1.28 mm of sensing spatial resolution, with ~13.16 pm/pm/°C of uniform temperature sensitivity, 0.149°C of uniform temperature precision, and 99.45% of the highest linearity. It successfully visualized dynamic hotspot migration on R&D pouch SIBs, identifying localized hotspots and thermal gradients that were undetectable by point sensors. Compared with conventional thermocouples (TCs), the proposed distributed temperature sensing method successfully reveals an additional 1.88 °C in the maximum surface temperature difference () during the discharging. When applied to a two-cell R&D SIBs module, the method can be employed to diagnose inter-cell thermal inconsistency. As the related results, the two cells exhibited distinctly different NUT trends starting as early as 30% DoD. Furthermore, Cell A illustrated a of 3.63°C and a faster decaying a normalized uniformity temperature (NUT) index of 0.11 at the final moment. Compared to Cell A, the Cell B shown the lower values at 2.56 °C with a final NUT index of 0.2. These relative comparisons suggested weaker thermal stability and higher dead sodium risk of Cell A than Cell B. Hence, this method can be demonstrated as a useful approach for high-resolution SIB thermal diagnosis and consistency screening in batteries.