Carlos Furnieles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlos Furnieles has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Camilo Zapata-Hernandez
Institución Universitaria Pascual Bravo, Medellin, Colombia, Colombia
1 shared publication - Erick Reyes-Vera
Grupo Automática, Electrónica y Ciencias Computacionales, Faculty of Engineering, Instituto Tecnológico Metropolitano—ITM, Medellin 050034, Colombia
1 shared publication - Javier Leonardo Araque Quijano
Department of Electrical and Electronic Engineering, Universidad Nacional de Colombia, Bogotá D.C. 111321, Colombia
1 shared publication - Jorge Montoya-Cardona
Department of Electronics and Telecommunications, Engineering Faculty, Institución Universitaria ITM, Medellín 050026, Colombia
1 shared publication - Juan Sebastián Botero Valencia
Grupo sistemas de Control y Robótica, Faculty of Engineering, Instituto Tecnológico Metropolitano, Medellin 050034, Colombia
1 shared publication - Paula Ortiz-Santana
Department of Electronics and Telecommunications Medellín Antioquia 050026 Instituto Tecnologico Metropolitano
1 shared publication
Latest Publications
- Open Access
Multiphysical Characterization of a Tissue-Mimicking Phantom: Composition, Thermal Behavior, and Broadband Electromagnetic Properties from Visible to Terahertz and Microwave Frequencies
A water-rich muscle-equivalent tissue-mimicking phantom within a polymeric matrix was experimentally evaluated through a multimodal characterization methodology to determine whether it reproduces the coupled dielectric–thermal behavior of hydrated biological tissue under exposure to electromagnetic waves. The material was analyzed using thermogravimetric analysis, microwave dielectric spectroscopy from 1.5 to 4.0 GHz, VIS–NIR spectroscopy between 350 and 1200 nm, and terahertz time-domain reflection. The thermogravimetric results confirmed dominant water content, with primary mass loss below 200 °C, establishing hydration as the governing factor of its thermal response. Next, the microwave dielectric measurements show that the phantom exhibits a relative permittivity of 37.4 and an electrical conductivity of 2.4 S/m. On the other hand, the VIS–NIR spectra show smooth broadband absorption with limited spatial variability, and principal component analysis reveals macroscopic optical homogeneity without structural spectral distortion. In the THz regime, strong broadband attenuation characteristic of water-rich matrices is observed, and reflection-mode measurements enable robust assessment of temporal stability through time- and frequency-domain signatures. Finally, a microwave thermal validation demonstrates stable behavior under low-power excitation, whereas under hyperthermia-level irradiation, a significant thermal drift of −3.985 °C/h was reached under non-adiabatic conditions, identifying hydration-mediated moisture redistribution as the principal limitation during prolonged high-power exposure. Collectively, these results demonstrate cross-regime dielectric–thermal consistency while explicitly defining the hydration-driven constraints governing long-term stability, providing a validated reference material for broadband electromagnetic and thermal biomedical experimentation.
Open AccessMultiphysical Characterization of a Tissue-Mimicking Phantom: Composition, Thermal Behavior, and Broadband Electromagnetic Properties from Visible to Terahertz and Microwave Frequencies
A water-rich muscle-equivalent tissue-mimicking phantom within a polymeric matrix was experimentally evaluated through a multimodal characterization methodology to determine whether it reproduces the coupled dielectric–thermal behavior of hydrated biological tissue under exposure to electromagnetic waves. The material was analyzed using thermogravimetric analysis, microwave dielectric spectroscopy from 1.5 to 4.0 GHz, VIS–NIR spectroscopy between 350 and 1200 nm, and terahertz time-domain reflection. The thermogravimetric results confirmed dominant water content, with primary mass loss below 200 °C, establishing hydration as the governing factor of its thermal response. Next, the microwave dielectric measurements show that the phantom exhibits a relative permittivity of 37.4 and an electrical conductivity of 2.4 S/m. On the other hand, the VIS–NIR spectra show smooth broadband absorption with limited spatial variability, and principal component analysis reveals macroscopic optical homogeneity without structural spectral distortion. In the THz regime, strong broadband attenuation characteristic of water-rich matrices is observed, and reflection-mode measurements enable robust assessment of temporal stability through time- and frequency-domain signatures. Finally, a microwave thermal validation demonstrates stable behavior under low-power excitation, whereas under hyperthermia-level irradiation, a significant thermal drift of −3.985 °C/h was reached under non-adiabatic conditions, identifying hydration-mediated moisture redistribution as the principal limitation during prolonged high-power exposure. Collectively, these results demonstrate cross-regime dielectric–thermal consistency while explicitly defining the hydration-driven constraints governing long-term stability, providing a validated reference material for broadband electromagnetic and thermal biomedical experimentation.