Francesca Dalla Corte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Francesca Dalla Corte has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Alberto Volta
Department of Morphology, Surgery and Experimental Medicine, Section of Anaesthesia and Intensive Care, Azienda Ospedaliera-Universitaria Sant’ Anna, University of Ferrara, Ferrara, Italy
2 shared publications - Savino Spadaro
University of Ferrara
2 shared publications A. Rundo
UOC Anestesia e Rianimazione, Polo ospedaliero Belcolle ASL, Viterbo, Italy
1 shared publication- Antonio Pesenti
Department of Pathophysiology and Transplantation, Università di Milano, Milan, Italy
1 shared publication B. Pavlovsky
Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
1 shared publication- Dan Stieper Karbing
Respiratory and Critical Care Group, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
1 shared publication
Latest Publications
- Open Access
- 3 May 2021
- Published by Oxford University Press (OUP)
- p. A2775
Effects of High Flow Nasal Cannula on Respiratory Effort in Patients with Extra-Pulmonary Sepsis or Septic Shock: A Sub-Phenotypes Analysis
- 3 May 2021
- Published by Oxford University Press (OUP)
- p. A2775
Open AccessEffects of High Flow Nasal Cannula on Respiratory Effort in Patients with Extra-Pulmonary Sepsis or Septic Shock: A Sub-Phenotypes Analysis
- 1 July 2018
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 46 (7) , e642-e648
An Open-Loop, Physiologic Model–Based Decision Support System Can Provide Appropriate Ventilator Settings
Objectives: To evaluate the physiologic effects of applying advice on mechanical ventilation by an open-loop, physiologic model–based clinical decision support system. Design: Prospective, observational study. Setting: University and Regional Hospitals’ ICUs. Patients: Varied adult ICU population. Interventions: Advice were applied if accepted by physicians for a period of up to 4–8 hours. Measurements and Main Results: Seventy-two patients were included for data analysis. Acceptance of advice was high with 95.7% of advice applied. In 41 patients in pressure support ventilation, following system advice led to significant decrease in PS, with PS reduced below 8 cm H2O in 15 patients (37%), a level not prohibiting extubation. Fraction of end-tidal CO2 values did not change, and increase in respiratory rate/VT was within clinical limits, indicating that in general, the system maintained appropriate patient breathing effort. In 31 patients in control mode ventilation, pressure control and tidal volume settings were decreased significantly, with tidal volume reduced below 8 mL/kg predicted body weight in nine patients (29%). Minute ventilation was maintained by a significant increase in respiratory rate. Significant reductions in Fio 2 were seen on elevated baseline median values of 50% in both support and control mode–ventilated patients, causing clinically acceptable reductions in oxygen saturation. Conclusions: The results indicate that during a short period, the clinical decision support system provided appropriate suggestions of mechanical ventilation in a varied ICU population, significantly reducing ventilation to levels which might be considered safe and beneficial.
- 1 July 2018
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 46 (7) , e642-e648
An Open-Loop, Physiologic Model–Based Decision Support System Can Provide Appropriate Ventilator Settings
Objectives: To evaluate the physiologic effects of applying advice on mechanical ventilation by an open-loop, physiologic model–based clinical decision support system. Design: Prospective, observational study. Setting: University and Regional Hospitals’ ICUs. Patients: Varied adult ICU population. Interventions: Advice were applied if accepted by physicians for a period of up to 4–8 hours. Measurements and Main Results: Seventy-two patients were included for data analysis. Acceptance of advice was high with 95.7% of advice applied. In 41 patients in pressure support ventilation, following system advice led to significant decrease in PS, with PS reduced below 8 cm H2O in 15 patients (37%), a level not prohibiting extubation. Fraction of end-tidal CO2 values did not change, and increase in respiratory rate/VT was within clinical limits, indicating that in general, the system maintained appropriate patient breathing effort. In 31 patients in control mode ventilation, pressure control and tidal volume settings were decreased significantly, with tidal volume reduced below 8 mL/kg predicted body weight in nine patients (29%). Minute ventilation was maintained by a significant increase in respiratory rate. Significant reductions in Fio 2 were seen on elevated baseline median values of 50% in both support and control mode–ventilated patients, causing clinically acceptable reductions in oxygen saturation. Conclusions: The results indicate that during a short period, the clinical decision support system provided appropriate suggestions of mechanical ventilation in a varied ICU population, significantly reducing ventilation to levels which might be considered safe and beneficial.