E. Weder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
E. Weder has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Aurel Mihai Vlaicu
National Institute of Materials Physics, Atomiştilor 405A, 077125 Măgurele, Romania
1 shared publication - Fernando Parente
Laboratório de Instrumentação, Engenharia Biomédica e Física da Radiação (LIBPhys-UNL), Departamento de Física, Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, Monte da Caparica, 2892-516 Caparica, Portugal
1 shared publication - Jorge Miguel Sampaio
LIP - Laboratory of Instrumentation and Experimental Particle Physics, Lisbon, Portugal; FCUL - Faculty of Sciences of the University of Lisbon, Lisbon, Portugal, Portugal
1 shared publication - Jose Paulo Santos
Laboratory of Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UNL), Department of Physics, NOVA School of Science and Technology, NOVA University Lisbon, 2829-516 Caparica, Portugal
1 shared publication - José Pires Marques
Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal
1 shared publication K. Sawicka
Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Gagarina7, 87-100 Toruń, Poland
1 shared publication
Latest Publications
- 11 May 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (5) , 052505
Structure of high-resolution x-ray emission spectra for the elements from Ca to GeThe x-ray spectra of the elements from Ca to Ge have been systematically investigated using a high-resolution antiparallel double-crystal x-ray spectrometer. Each natural linewidth has been corrected using the instrumental function of this type of x-ray spectrometer, and the spin doublet energies have been obtained from the peak position values in x-ray spectra. For all studied elements the corrected x-ray lines FWHM increase linearly as a function of . However, for x-ray lines this dependence is generally not linear in the case of elements but increases from Sc to Co elements. It has been found that the contributions of satellite lines are considered to be shake processes. Our theoretically predicted synthetic spectra of Ca, Mn, Cu, and Zn are in very good agreement with our high-resolution measurements, except in the case of Mn, due to the open-shell valence configuration effect (more than 7000 transitions for diagram lines and more than transitions for satellite lines) and the influence of the complicated structure of the metallic Mn.- 11 May 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (5) , 052505
Structure of high-resolution x-ray emission spectra for the elements from Ca to GeThe x-ray spectra of the elements from Ca to Ge have been systematically investigated using a high-resolution antiparallel double-crystal x-ray spectrometer. Each natural linewidth has been corrected using the instrumental function of this type of x-ray spectrometer, and the spin doublet energies have been obtained from the peak position values in x-ray spectra. For all studied elements the corrected x-ray lines FWHM increase linearly as a function of . However, for x-ray lines this dependence is generally not linear in the case of elements but increases from Sc to Co elements. It has been found that the contributions of satellite lines are considered to be shake processes. Our theoretically predicted synthetic spectra of Ca, Mn, Cu, and Zn are in very good agreement with our high-resolution measurements, except in the case of Mn, due to the open-shell valence configuration effect (more than 7000 transitions for diagram lines and more than transitions for satellite lines) and the influence of the complicated structure of the metallic Mn.