Bibhu Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bibhu Sharma has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Adrienne Ji
Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
1 shared publication- Chi Cong Nguyen
School of Mechanical and Manufacturing Engineering Faculty of Engineering University of New South Wales (UNSW Sydney) Sydney New South Wales Australia
1 shared publication - Christopher Simon Hayward
Faculty of Medicine University of New South Wales Kensington New South Wales Australia
1 shared publication Emanuele Nicotra
Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
1 shared publication- Hoang-Phuong Phan
School of Mechanical and Manufacturing Engineering The University of New South Wales Sydney New South Wales Australia
1 shared publication - James Davies
UNSW Sydney
1 shared publication
Latest Publications
- 25 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (94) , eado4553
Soft robotic artificial left ventricle simulator capable of reproducing myocardial biomechanics
The heart’s intricate myocardial architecture has been called the Gordian knot of anatomy, an impossible tangle of intricate muscle fibers. This complexity dictates equally complex cardiac motions that are difficult to mimic in physical systems. If these motions could be generated by a robotic system, then cardiac device testing, cardiovascular disease studies, and surgical procedure training could reduce their reliance on animal models, saving time, costs, and lives. This work introduces a bioinspired soft robotic left ventricle simulator capable of reproducing the minutiae of cardiac motion while providing physiological pressures. This device uses thin-filament artificial muscles to mimic the multilayered myocardial architecture. To demonstrate the device’s ability to follow the cardiac motions observed in the literature, we used canine myocardial strain data as input signals that were subsequently applied to each artificial myocardial layer. The device’s ability to reproduce physiological volume and pressure under healthy and heart failure conditions, as well as effective simulation of a cardiac support device, were experimentally demonstrated in a left-sided mock circulation loop. This work also has the potential to deliver faithful simulated cardiac motion for preclinical device and surgical procedure testing, with the potential to simulate patient-specific myocardial architecture and motion.
- 25 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (94) , eado4553
Soft robotic artificial left ventricle simulator capable of reproducing myocardial biomechanics
The heart’s intricate myocardial architecture has been called the Gordian knot of anatomy, an impossible tangle of intricate muscle fibers. This complexity dictates equally complex cardiac motions that are difficult to mimic in physical systems. If these motions could be generated by a robotic system, then cardiac device testing, cardiovascular disease studies, and surgical procedure training could reduce their reliance on animal models, saving time, costs, and lives. This work introduces a bioinspired soft robotic left ventricle simulator capable of reproducing the minutiae of cardiac motion while providing physiological pressures. This device uses thin-filament artificial muscles to mimic the multilayered myocardial architecture. To demonstrate the device’s ability to follow the cardiac motions observed in the literature, we used canine myocardial strain data as input signals that were subsequently applied to each artificial myocardial layer. The device’s ability to reproduce physiological volume and pressure under healthy and heart failure conditions, as well as effective simulation of a cardiac support device, were experimentally demonstrated in a left-sided mock circulation loop. This work also has the potential to deliver faithful simulated cardiac motion for preclinical device and surgical procedure testing, with the potential to simulate patient-specific myocardial architecture and motion.