Dina Ermanova
Dina Ermanova has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Askar Abdykadyrov
Department of Electronics, Telecommunications and Space Technologies, Satbayev University, Almaty 050013, Kazakhstan
2 shared publications - Nurlan Kystaubayev
Department of Electronics, Telecommunications and Space Technologies, Satbayev University, Almaty 050013, Kazakhstan
2 shared publications - Nurzhigit Smailov
Department of Electronics, Telecommunications and Space Technologies, Satbayev University, Almaty 050013, Kazakhstan
2 shared publications - Ainur Kuttybayeva
Satbayev University
1 shared publication - Gulbakhar Yussupova
1 Department of Radio Engineering and Telecommunications ALT University, Shevchenko str., 97, Almaty, 050010, Republic of Kazakhstan
1 shared publication - Madina Koshkinbayeva
Department of Mathematics, Physics and Computer Science, Central Asian Innovation University, 80A Baitursynov Street, Shymkent 160000, Kazakhstan
1 shared publication
Latest Publications
- Open Access
- 16 July 2026
- Published by JVE International Ltd. in Vibroengineering PROCEDIA
- Vol. 63, 145-152
Analytical assessment of the reliability of the FBG multi-sensor network for monitoring CFRP structures based on the k-out-of-n model
In this paper, an analytical assessment of the long-term operability of the FBG multi-sensor network used for monitoring defects in CFRP structures was carried out. The main focus of the article is devoted to assessing the reliability level of a generalized FBG sensor network, and not the effectiveness of experimental detection of a defect in a specific CFRP sample. For this reason, the study does not consider the diagnostic sensitivity of the structural health monitoring system or the probability of detecting a defect, but the functional stability of the network in the event of sensor failure. The system reliability was calculated using the k-out-of-n model, and the time-dependent reliability of an individual sensor was characterized by an exponential law. The configuration n = 120 and k = 100 was chosen as the main calculation scenario. This configuration was considered a representative redundancy model that characterized the system’s operability even in the event of a failure of about 16.7 % of the sensors. Calculations were carried out for 0-60 months for failure intensities λ = 0.005, 0.01, 0.02 and 0.05 months -1 . The results showed that as the degradation intensity of an individual sensor increases, system reliability decreases dramatically. At the same time, a sensitivity analysis of k/n configurations was performed, demonstrating an engineering trade-off between redundancy and the minimum number of operating sensors. The results obtained enable the selection of the maintenance interval, sensor replacement strategy, and level of redundancy on a scientific basis when designing SHM systems based on FBG.
- 16 July 2026
- Published by JVE International Ltd. in Vibroengineering PROCEDIA
- Vol. 63, 145-152
Open AccessAnalytical assessment of the reliability of the FBG multi-sensor network for monitoring CFRP structures based on the k-out-of-n model
In this paper, an analytical assessment of the long-term operability of the FBG multi-sensor network used for monitoring defects in CFRP structures was carried out. The main focus of the article is devoted to assessing the reliability level of a generalized FBG sensor network, and not the effectiveness of experimental detection of a defect in a specific CFRP sample. For this reason, the study does not consider the diagnostic sensitivity of the structural health monitoring system or the probability of detecting a defect, but the functional stability of the network in the event of sensor failure. The system reliability was calculated using the k-out-of-n model, and the time-dependent reliability of an individual sensor was characterized by an exponential law. The configuration n = 120 and k = 100 was chosen as the main calculation scenario. This configuration was considered a representative redundancy model that characterized the system’s operability even in the event of a failure of about 16.7 % of the sensors. Calculations were carried out for 0-60 months for failure intensities λ = 0.005, 0.01, 0.02 and 0.05 months -1 . The results showed that as the degradation intensity of an individual sensor increases, system reliability decreases dramatically. At the same time, a sensitivity analysis of k/n configurations was performed, demonstrating an engineering trade-off between redundancy and the minimum number of operating sensors. The results obtained enable the selection of the maintenance interval, sensor replacement strategy, and level of redundancy on a scientific basis when designing SHM systems based on FBG.
- Open Access
- 1 June 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (6) , 237-252
Development and experimental validation of intelligent control systems for high-frequency ozonators
Improving the environmental safety and energy efficiency of water disinfection technologies is a key challenge in ecological engineering. This study proposes and experimentally validates a hybrid intelligent control system for a high – frequency ozonator based on a plasma – liquid process,...
- 1 June 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (6) , 237-252
Open AccessDevelopment and experimental validation of intelligent control systems for high-frequency ozonators
Improving the environmental safety and energy efficiency of water disinfection technologies is a key challenge in ecological engineering. This study proposes and experimentally validates a hybrid intelligent control system for a high – frequency ozonator based on a plasma – liquid process,...
- Open Access
- 3 March 2026
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 15 (2) , 26
Research and Development of Intelligent Control Systems for High-Frequency Ozone Generators
This paper presents the development and investigation of an intelligent control system for a high-frequency ozone generator integrated into an IoT-based and telecommunication environment. A cyber-physical nonlinear mathematical model combining the electrical, thermal, gas-dynamic, and chemical subsystems of the ozone generation process is proposed. The model was implemented in discrete-time form and experimentally validated using the corona–discharge-based high-frequency ozonator ETRO-02. The deviation between simulation and experimental results did not exceed 5.3% for settling time, 6.7% for overshoot, 1.6% for steady-state ozone concentration, and 0.9% for gas temperature, confirming the adequacy of the proposed model. Based on this model, a hierarchical two-level intelligent control architecture is synthesized, consisting of a fast local control loop with a cycle time of 1–5 ms and a supervisory monitoring layer. The proposed adaptive state-feedback control law with online gain adjustment ensures stable real-time operation under nonlinear dynamics, ±20% parameter variations, network delays of 1–10 ms, and packet loss probabilities of up to 5%. As a result, the settling time is reduced from 420 ms to 160 ms, the overshoot from 12.5% to 3.1%, and the steady-state error from 6.5% to 1.6%, while the specific energy consumption decreases from 11.8 to 6.2 Wh/m3. The obtained results demonstrate that the integration of a cyber-physical model with a millisecond-level intelligent control system significantly improves the dynamic performance, robustness, and energy efficiency of high-frequency ozone generators compared to classical control and monitoring-oriented IoT systems. Unlike cloud-centric IoT monitoring architectures that operate at second-level update cycles, the proposed system closes the control loop locally at the millisecond scale, enabling stabilization of fast nonlinear electro-plasma dynamics. The results demonstrate that edge-intelligent adaptive control significantly enhances both dynamic performance and energy efficiency, confirming the feasibility of millisecond-level cyber-physical regulation for industrial ozone generation systems.
- 3 March 2026
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 15 (2) , 26
Open AccessResearch and Development of Intelligent Control Systems for High-Frequency Ozone Generators
This paper presents the development and investigation of an intelligent control system for a high-frequency ozone generator integrated into an IoT-based and telecommunication environment. A cyber-physical nonlinear mathematical model combining the electrical, thermal, gas-dynamic, and chemical subsystems of the ozone generation process is proposed. The model was implemented in discrete-time form and experimentally validated using the corona–discharge-based high-frequency ozonator ETRO-02. The deviation between simulation and experimental results did not exceed 5.3% for settling time, 6.7% for overshoot, 1.6% for steady-state ozone concentration, and 0.9% for gas temperature, confirming the adequacy of the proposed model. Based on this model, a hierarchical two-level intelligent control architecture is synthesized, consisting of a fast local control loop with a cycle time of 1–5 ms and a supervisory monitoring layer. The proposed adaptive state-feedback control law with online gain adjustment ensures stable real-time operation under nonlinear dynamics, ±20% parameter variations, network delays of 1–10 ms, and packet loss probabilities of up to 5%. As a result, the settling time is reduced from 420 ms to 160 ms, the overshoot from 12.5% to 3.1%, and the steady-state error from 6.5% to 1.6%, while the specific energy consumption decreases from 11.8 to 6.2 Wh/m3. The obtained results demonstrate that the integration of a cyber-physical model with a millisecond-level intelligent control system significantly improves the dynamic performance, robustness, and energy efficiency of high-frequency ozone generators compared to classical control and monitoring-oriented IoT systems. Unlike cloud-centric IoT monitoring architectures that operate at second-level update cycles, the proposed system closes the control loop locally at the millisecond scale, enabling stabilization of fast nonlinear electro-plasma dynamics. The results demonstrate that edge-intelligent adaptive control significantly enhances both dynamic performance and energy efficiency, confirming the feasibility of millisecond-level cyber-physical regulation for industrial ozone generation systems.