CGCarlos Gonzalez Gonzalez

Carlos Gonzalez Gonzalez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carlos Gonzalez Gonzalez has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Musculoskeletal Disorders Among Endourologists: A Review of Occupational Risk in Endourological Procedures

    by Pietro Scilipoti, Federico Zorzi, Carlos Gonzalez Gonzalez, Luca Villa, Eugenio Ventimiglia, Andrea Salonia, Alberto Briganti, Francesco Montorsi, Chady Ghnatios, Carlotta Nedbal, et al.

    Objective: Work-related musculoskeletal disorders (WMSDs) are increasingly recognized among surgeons, yet their burden across the full spectrum of endourological practice has not been systematically characterized. This review aimed to assess the prevalence, anatomical distribution, and determinants of MSDs among endourologists. Evidence Acquisition: A preregistered protocol (PROSPERO: CRD420261394815) guided a systematic search of PubMed and EMBASE. Thirty studies met the inclusion criterion, encompassing surveys, prospective cohort studies, randomized controlled trials, surface electromyography studies, biomechanical experiments, and clinical registries. Quality was assessed using the Newcastle–Ottawa Scale and Cochrane RoB 2 tool. Heterogeneity in study design and outcome precluded formal meta-analysis, and a narrative synthesis was performed. Evidence Synthesis: WMSDs affect the majority of practicing endourologists, with prevalence estimates ranging from 32% to 86%. Endourology independently predicted chronic MSDs (odds ratio 3.06, 95% confidence interval 1.37–6.80). Flexible ureteroscopy (fURS) was associated with the highest anatomical burden, affecting the neck, shoulder, upper back, and hand–wrist complex; heavier reusable fiber-optic scopes generate significantly greater muscle activation than lighter single-use digital instruments. Percutaneous nephrolithotomy can result in substantial erector spinae loading, with prone positioning the most demanding configuration; heavy lithotripter handpieces received consistently poor ergonomic ratings. Transurethral endoscopy (transurethral resection of the prostate/bladder tumor) commonly causes trapezius fatigue in most procedures, with predicted muscular endurance time approximating operative duration; video-assisted monitor endoscopy halved fatigue incidence. Laser prostatectomy (holmium laser enucleation of the prostate) is associated with high neck and shoulder burden, compounded by gland size and operative duration. Several reports demonstrated that robotic fURS dramatically reduced ergonomic burden (total score 5.6 vs 31.3, p < 0.01). Conclusions: MSDs are a significant, under-addressed occupational hazard in endourology. Ergonomics deserve the same priority afforded to robotics in surgical innovation. Instrument redesign, ergonomic operating room configuration, structured training, and greater awareness, including within residency curricula, offer actionable mitigation. Prospective, standardized, multicenter research is urgently needed.

  • Flexible and navigable suction ureteric access sheath and direct‐in‐scope suction in endourology: a systematic evidence map of study characteristics and research trends

    by Pietro Scilipoti, Federico Zorzi, Carlos Gonzalez Gonzalez, Nicola Nannola, Marie Chicaud, Luigi Candela, Eugenio Ventimiglia, Alberto Briganti, Andrea Salonia, Francesco Montorsi, et al.

    Objective: To characterise the global research landscape of suction technologies in flexible ureteroscopy, specifically the flexible and navigable suction ureteric access sheath (FANS) and direct‐in‐scope suction (DISS), mapping study design, geographical and temporal trends, risk of bias, and clinical and experimental applications. Methods: A systematic search of PubMed, the Excerpta Medica dataBASE (EMBASE), and Web of Science was performed per Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines (International Prospective Register of Systematic Reviews: CRD420261371338). All study designs were eligible, including randomised controlled trials (RCTs), prospective and retrospective observational studies, experimental studies ( in vivo , ex vivo , in vitro ), and case series. Country was assigned by first‐author affiliation as a proxy for research leadership. Risk of bias was assessed with design‐appropriate tools: the Cochrane Risk of Bias 2 (RoB 2) tool for RCTs, Risk Of Bias In Non‐randomised Studies of Interventions (ROBINS‐I) for non‐randomised studies, Quality Assessment Tool For In Vitro Studies (QUIN) for laboratory studies, and the Newcastle–Ottawa Scale for case series. Results: A total of 154 studies were included (2022–2026). Annual publication rate increased from three studies in 2022 to >80 in 2025. China accounted for 48.7% of publications, followed by Singapore (11.7%) and Armenia (5.2%). Retrospective comparative studies were the largest design group (49 [31.8%]), followed by in vitro experiments (22 [14.3%]), prospective comparative studies (19 [12.3%]), and RCTs (11 [7.1%]). Most clinical studies were single‐centre (55.8%); multicentre collaboration was more common in prospective and European Association of Urology‐affiliated research. Adult urolithiasis accounted for 72% of clinical studies; paediatric studies, 2.6% (FANS only). Under ROBINS‐I, 61% of observational studies were rated moderate risk of bias; 81% of RCTs raised some concerns under RoB 2; laboratory studies were predominantly low risk. Conclusions: This evidence map shows FANS and DISS have generated a rapidly expanding literature, heavily dominated by single‐centre retrospective studies from Asia. RCT‐level evidence is emerging for FANS, while DISS evidence remains earlier‐stage and less mature. Standardised outcome reporting, multicentre prospective designs, and broader geographic representation are the priorities this evidence map identifies for the field.

  • CT urography and urinary cytology in surveillance of endoscopically managed UTUC

    by Pietro Scilipoti, Raffaele La Mura, Federico Zorzi, Marie Chicaud, Nicola Nannola, Carlos Gonzalez Gonzalez, Andrea Folcia, Angelo Occhi, Andrea Cosenza, Eugenio Ventimiglia, et al.

    Objective: Our objective was to assess whether non‐invasive surveillance with computed tomography (CT) urography and urinary cytology could safely reduce the need for ureteroscopy (URS) in patients with upper tract urothelial carcinoma treated with endoscopic kidney‐sparing surgery (eKSS). Patients and Methods: We performed a retrospective multicentre analysis of patients undergoing eKSS for upper tract urothelial carcinoma at two tertiary centres (2006–2025). Surveillance included second‐look URS at 4–6 weeks, then every 6 months for 2 years and annually thereafter. CT urography and urinary cytology were performed within 3 months before each URS, and this served as the reference standard. Four trigger strategies were evaluated for diagnostic performance. Analysis started from the third URS. Recurrence over time was analysed using annualized rates per person‐year, accounting for multiple recurrences and treating radical nephroureterectomy as a competing event, overall and by risk group. Results: A total of 133 patients and 256 ureteroscopic assessments were included. Combined CT and/or cytology showed sensitivity of 35.5%, specificity of 75.0%, a positive predictive value of 64.1% (95% confidence interval [CI] 52.4–74.7), and a negative predictive value of 48.0% (95% CI 40.4–55.7), avoiding 69.2% of URS (95% CI 63.1–74.8) but missing 64.5% of recurrences (95% CI 56.0–72.4). Cytology alone was highly specific (97%) but poorly sensitive (11%); CT alone showed moderate sensitivity (27%) and good specificity (78%); requiring both to be positive yielded near‐perfect specificity but near‐zero sensitivity (2.8%). Recurrence rates were stable across follow‐up years at 0.34, 0.35, 0.35, and 0.28 events/person‐year at years 1–4 in the low‐risk group, and 0.33, 0.38, 0.32, and 0.32 in the high‐risk group. Conclusions: CT urography and urinary cytology may reduce the frequency of URS but cannot safely replace endoscopic surveillance because of the high rate of missed recurrences. Stable recurrence rates over time support the need for continued long‐term endoscopic follow‐up after eKSS.

  • Optimizing Tissue Acquisition in Upper Tract Urothelial Carcinoma: A Systematic Review and Meta-Analysis of Ureteroscopy Biopsy Forceps

    by Carlos González González, Pietro Scilipoti, Federico Zorzi, Nicola Nannola, Marie Chicaud, Frédéric Panthier, Olivier Traxer

    Objectives: To evaluate the performance of flexible ureteroscopy (fURS) biopsy forceps for tissue acquisition in upper tract urothelial carcinoma (UTUC), stratified by device, and their concordance with surgical pathology. Methods: Preregistered systematic review and meta-analysis (PROSPERO CRD420261392641; PRISMA 2020). MEDLINE and Embase were searched to 1 May 2026 for studies of forceps-based fURS biopsy in UTUC. The primary outcome was diagnostic yield; secondary outcomes included specimen adequacy, lamina propria presence, grade concordance, undergrading, and upstaging to muscle-invasive disease. Pooled proportions used the Freeman-Tukey double-arcsine transformation with DerSimonian-Laird random-effects models; heterogeneity was assessed with Cochran’s Q. Results: Nineteen studies (1397 patients; 1,773 biopsies; 1985–2025) were included. Pooled diagnostic yield was 84.6% (95% confidence interval 77.5%–90.6%; Q = 80.90, df = 10, p < 0.001), and specimen adequacy was 82.0% (76.7%–86.8%). Neither was distinguished by device category (subgroup Q = 6.12, df = 3, p = 0.11 and Q = 6.88, df = 3, p = 0.076). Overall grade concordance was 78.8% (69.9%–86.7%), and 28.3% of tumors were undergraded (18.1%–39.7%). Lamina propria was present in only 71.8% of specimens, and 54.6% (35.8%–72.7%) of tumors appearing non-muscle-invasive at biopsy were upstaged to ≥pT2 at nephroureterectomy. Ex vivo , backloaded forceps caused 6.4-fold less deflection loss than the Piranha (12.7° vs 80.7°) without improving yield. Conclusions: Across four decades of evidence, ureteroscopic biopsy forceps achieve approximately 85% diagnostic yield, with no single design demonstrably superior. The determinants of a diagnostic, accurately graded biopsy may therefore lie less in the instrument than in factors this review could not test directly, including operator experience and sampling strategy; whether systematic multisite sampling improves diagnostic yield is a hypothesis that requires prospective evaluation. At the same time, frequent undergrading and upstaging, with often inadequate specimens, expose the diagnostic ceiling of current devices and make dedicated device redesign and prospective, device-stratified research a clear priority.

  • Endoscopic kidney‐sparing surgery for upper tract urothelial carcinoma in patients with a solitary kidney

    by Pietro Scilipoti, Federico Zorzi, Carlos Gonzalez Gonzalez, Nicola Nannola, Stefano Moretto, Letizia Maria Ippolita Jannello, Ugo Gradilone, Marie Chicaud, Andrea Folcia, Angelo Occhi, et al.

    Objective: To evaluate cancer control, renal function trajectories, and dialysis risk in patients with a solitary kidney treated with endoscopic kidney‐sparing surgery (eKSS) for upper tract urothelial carcinoma (UTUC). Patients and Methods: We conducted a retrospective multicentre cohort study including 62 consecutive patients with UTUC and a solitary kidney treated with primary eKSS between 2006 and 2024 at two tertiary referral centres. All patients underwent ureteroscopic biopsy and laser ablation followed by intensified surveillance with mandatory second‐look ureteroscopy and repeat retreatment as needed. Primary endpoints were upper tract recurrence, progression, cancer‐specific mortality, and dialysis dependency. Competing‐risk cumulative incidence functions and linear mixed‐effects models were used. Results: Median age was 71 years (interquartile range [IQR] 67–77), and baseline estimated glomerular filtration rate (eGFR) was 48 mL/min/1.73 m 2 (IQR 40–70). High‐grade disease at initial ureteroscopy was present in 12 patients (19%). Over a median follow‐up of 65 months, patients underwent a median of five ureteroscopies (IQR 3–9), and 16 (26%) ultimately underwent radical nephroureterectomy. The cumulative incidence of upper tract recurrence was 70% (95% confidence interval [CI] 58–83) at 5 years. The 5‐year cumulative incidence of progression was 40% (95% CI 26–54). Cancer‐specific mortality was 20% (95% CI 7.9–32) at 5 years. Dialysis dependency occurred in 32% (95% CI 18–45) at 5 years, predominantly among patients with baseline eGFR 2 (hazard ratio 5.68; 95% CI 1.20–27.0, P = 0.029). Mixed‐effects modelling showed a mean annual eGFR decline of 2.9 mL/min/1.73 m 2 (95% CI 1.2–4.6). Conclusions: In patients with UTUC and a solitary kidney, eKSS delivered within an intensive surveillance programme provided durable renal preservation with acceptable oncological outcomes. Despite frequent recurrences requiring repeated ureteroscopic interventions, cancer‐specific mortality remained limited, supporting eKSS as a viable alternative to radical nephroureterectomy in imperative clinical settings.

  • Endoluminal anatomy in retrograde ureteroscopy: surgical landmarks and clinical implications

    by Carlos González, Pietro Scilipoti, Federico Zorzi, Nicola Nannola, Raffaele La Mura, Hubert Werth, Marie Chicaud, Steeve Doizi, Olivier Traxer, Frédéric Panthier

  • Kidney stones composition prediction using artificial intelligence ( KiSCAI) study

    by Louise Duffaut, Pietro Scilipoti, Zine‐Eddine Khene, Steeve Doizi, Vincent Frochot, Laurent Berthe, Federico Zorzi, Nicola Nannola, Carlos Gonzalez Gonzalez, Jean Philippe Haymann, et al.

    Objectives: To develop and validate explainable machine learning (ML) models predicting urinary stone composition from routinely available clinical variables and standardised morphological features, and to quantify the incremental value of morphology. Patients and Methods: This retrospective cohort study included consecutive patients undergoing endourological treatment or spontaneous stone expulsion, with laboratory analysis showing a major component exceeding 50% of stone composition, between 2019 and 2024. The outcome was dominant stone composition, classified into five categories: calcium oxalate monohydrate (COM), calcium oxalate dihydrate (COD), calcium phosphate, uric acid, and cystine. Predictors included demographics, comorbidities, stone metrics, procedural details, and Daudon‐based morphological descriptors. Data were split into stratified training and validation cohorts (80% and 20%, respectively). Predictor stability was assessed using repeated‐resampling multiclass Least Absolute Shrinkage and Selection Operator (LASSO). Multiple supervised classifiers (logistic regression, support vector machine, random forest, ExtraTrees, Adaptive Boosting [AdaBoost] variants, Extreme Gradient Boosting [XGBoost], Categorical Boosting [CatBoost]) were fine‐tuned using GridSearch. Discrimination was assessed using macro‐averaged one‐vs‐rest area under the curve (AUC) and accuracy. Explainability relied on SHapley Additive exPlanations (SHAP). Results: Among 442 patients (median age 51 years; 67% male), stone composition was COM in 41.0% ( n = 181), COD in 24.9% ( n = 110), calcium phosphate in 19.7% ( n = 87), uric acid in 10.9% ( n = 49), and cystine in 3.6% ( n = 16). LASSO stability highlighted reproducible predictors, including age, hereditary disease type, stone density, maximal diameter, and location. Clinical‐only models achieved good discrimination (macro‐AUC up to 0.809). Adding morphological features markedly improved performance, with ensemble models achieving excellent discrimination in validation (macro‐AUC up to 0.983 with CatBoost). Morphological variables ranked among the strongest contributors on SHAP. Conclusions: A clinical‐only model can predict the major stone component and may support preoperative decision‐making. Performance further improved when morpho‐constitutional features were added, confirming Daudon's classification as the ground truth; however, this combined model relies on intra‐ and postoperative descriptors and is best regarded as an intra‐ or postoperative decision‐support tool rather than a preoperative one. External prospective validation is needed before clinical implementation.

  • Open Access

    Diagnostic performance of intraoperative urine dipstick testing during ureteroscopy: association with culture positivity and severe infection

    by Carlos González González, Pietro Scilipoti, Federico Zorzi, Nicola Nannola, Marie Chicaud, Frédéric Panthier, Olivier Traxer

    Ureteroscopy (URS) is a widely performed procedure for urinary stone disease, yet infectious complications, including sepsis, remain a concern despite negative preoperative urine cultures. Intraoperative urine dipstick testing offers a rapid point-of-care assessment, but its diagnostic performance for predicting culture positivity and severe infection at different sampling sites during URS remains unclear. In this retrospective, single-center study, 238 patients undergoing URS were included. Paired urine dipstick and culture samples were obtained from bladder urine, intraoperative pelvic urine, and post-laser pelvic urine. Dipstick positivity was defined using two criteria: leukocytes and/or nitrites (OR definition) and leukocytes and nitrites (AND definition). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals were calculated for predicting culture positivity. Receiver operating characteristic (ROC) curve analysis was performed, including a composite dipstick score (0–2). Severe postoperative infection was assessed as a secondary exploratory outcome. Culture positivity ranged from 18.4% (bladder) to 22.9% (intraoperative pelvic urine). Using the OR definition, pooled sensitivity was 80.5% and specificity 47.6%, whereas the AND definition yielded lower sensitivity (43.8%) and higher specificity (86.4%). Diagnostic performance varied by sampling site, with intraoperative pelvic urine demonstrating the most balanced metrics. ROC analysis showed moderate discriminative performance, with the highest AUC observed for pelvic urine sampled prior to laser fragmentation (AUC 0.723, 95% CI 0.646–0.801). For severe infection (4.2%), dipstick testing demonstrated low sensitivity (30%), and this analysis was considered exploratory. Intraoperative urine dipstick testing demonstrates moderate diagnostic performance for predicting culture positivity during URS, with results influenced by sampling site and positivity definition. Pre-laser pelvic sampling provides the most informative results. A negative intraoperative dipstick, particularly from pre-laser pelvic urine, may help identify patients at lower likelihood of culture positivity; however, the test remains insufficient to guide antimicrobial or postoperative decision-making in isolation. Further prospective studies are required to validate its role in perioperative risk stratification.

  • Open Access

    Bacterial biofilms in calcium oxalate kidney stones: Where do we stand?

    by Carlos González González, Federico Zorzi, Michel Daudon, Olivier Traxer


  • Open Access

    Flexible ureterorenoscopy and lithotripsy with pulsed thulium: YAG laser: a multicenter retrospective study

    by Carlos González González, Jia-Lun Kwok, Pietro Scilipoti, Federico Zorzi, Laurent Berthe, Nicola Nannola, Hubert Werth, Chicaud Marie, Stefano Moretto, Juan Manuel López Martínez, et al.

    Introduction: In vivo data on volumetric laser efficiency and clinical outcomes of the p-Tm: YAG laser from large multicenter cohorts remain limited. The present study aimed to evaluate the real-world in vivo volumetric ablation efficiency of the p-Tm: YAG laser during flexible ureterorenoscopy (FURS), with secondary assessment of clinical outcomes and safety in a multicenter cohort. Methods: We conducted a retrospective multicenter cohort study including adult patients (≥ 18 years) who underwent p-Tm: YAG–based FURS for ureteral and/or renal calculi at three tertiary referral centers between 2023 and 2025. Preoperative stone volume was quantified using manual three-dimensional CT segmentation. Laser-on time (LOT), total delivered energy, and laser settings were prospectively recorded. Volumetric ablation speed (mm³/s) and energy consumption (J/mm³) were calculated using standardized definitions based on segmented pre- and postoperative stone volumes in patients with postoperative non-contrast CT (NCCT). Stone-free rate (SFR) was assessed 1–3 months postoperatively using NCCT and classified as Grade A (no residual fragments), Grade B (residual fragments ≤ 2 mm), and Grade C (residual fragments ≤ 4 mm). In patients without postoperative NCCT, SFR was assessed by intraoperative endoscopic evaluation and analyzed separately. Results: Of 222 screened patients, 167 met the inclusion criteria. Median preoperative stone volume was 987 mm³ (IQR 329–3,124), and 47% of patients presented with multiple/complex stones. Median LOT was 21.4 min, and median total delivered energy was 12 kJ. In the 108 patients with paired volumetric data and postoperative NCCT, median ablation speed was 0.55 mm³/s (IQR 0.30–0.95), and median energy consumption was 13 J/mm³ (IQR 8–23). In this NCCT subgroup, SFR were 47%, 59%, and 66% for Grade A, B, and C, respectively. Among the 59 patients assessed endoscopically only, complete stone clearance was visually assessed in 20 patients (34%). Overall, 45 patients (27%) required additional stone-related treatment. Complications were uncommon, with 4.8% Clavien–Dindo grade I–II events and 0.6% grade III events; no grade IV–V complications were observed. Conclusion: In this multicenter real-world cohort, p-Tm: YAG laser lithotripsy showed measurable volumetric efficiency and was associated with acceptable stone clearance and a favorable safety profile during FURS. These findings support the clinical feasibility of this technology in routine endourological practice; however, prospective comparative studies are warranted to further define its relative performance compared with established laser platforms.