N. Kamikubota
N. Kamikubota has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Akio Ueno
Horonobe Research Institute for the Subsurface Environment (H-RISE), Northern Advancement Centre for Science and Technology (NOASTEC), Sakae-machi 5-3, Horonobe-cho, Hokkaido, 098-3221, Japan
1 shared publication H. Akikawa
Japan Atomic Energy Agency#TAB
1 shared publicationI. Abe
National Laboratory for High Energy Physics(KEK), Oho 1-1, Tsukuba-shi, Ibaraki-ken, 305 Japan
1 shared publicationK. Nakahara
National Laboratory for High Energy Physics(KEK), Oho 1-1, Tsukuba-shi, Ibaraki-ken, 305 Japan
1 shared publication- Kazuro Furukawa
High Energy Accelerator Research Organization
1 shared publication - Masiki Ikegami
Bioproduction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Sapporo 062-8517, Japan
1 shared publication
Latest Publications
- 15 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19444680,p. 2777-2779
Developments of the Calibation Tools for Beam Position Monitor at J-PARC Linac
In the J-PARC LINAC, there are mainly two requirements for calibration of beam position monitors (BPMs). One is that BPMs need to be calibrated with the accuracy of less than about a hundred micrometers to minimize beam loss for the world highest class of proton intensity. The other is that about a hundred of BPMs need to be calibrated and maintained consistently. To achieve these requirements, the calibration tools are being developed. During development, experiences on real beam in a MEBT line set for the DTL commissioning are utilized. The status of the development of calibration tools is described in this paper.
- 15 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19444680,p. 2777-2779
Developments of the Calibation Tools for Beam Position Monitor at J-PARC Linac
In the J-PARC LINAC, there are mainly two requirements for calibration of beam position monitors (BPMs). One is that BPMs need to be calibrated with the accuracy of less than about a hundred micrometers to minimize beam loss for the world highest class of proton intensity. The other is that about a hundred of BPMs need to be calibrated and maintained consistently. To achieve these requirements, the calibration tools are being developed. During development, experiences on real beam in a MEBT line set for the DTL commissioning are utilized. The status of the development of calibration tools is described in this paper.
- 1 December 1994
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 352 (1-2) , 131-134
New control system with VME and workstations for the KEK e−/e+ linac
- 1 December 1994
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 352 (1-2) , 131-134
New control system with VME and workstations for the KEK e−/e+ linac