Huaqi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huaqi Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jianqiang Shan
School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Xiaoya Kang
Northwest Institute of Nuclear Technology, 28 Pingyu Road, Xi’an 710024, China
2 shared publications - Xiaoyan Tian
Northwest Institute of Nuclear Technology, 28 Pingyu Road, Xi’an 710024, China
2 shared publications - Xinbiao Jiang
Northwest Institute of Nuclear Technology, 28 Pingyu Road, Xi’an 710024, China
2 shared publications - Da Li
Northwest Institute of Nuclear Technology, Xi’an 710024, China
1 shared publication - Huaqi Li
School of Nuclear Science and Technology, Xi’an Jiaotong University, 28 Xianning West Road, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
Improvement and Validation of the System Analysis Model and Code for Heat-Pipe-Cooled Microreactor
Heat-pipe-cooled microreactors (HPMR) use a passive high-temperature alkali metal heat pipe to directly transfer the heat of solid core to the hot end of the intermediate heat exchanger or thermoelectric conversion device, thus avoiding a single point failure. To analyze and evaluate the transient safety characteristics of an HPMR system under accident conditions, such as heat pipe failure in the core or a loss of system heat sink and other accidents, a previously developed model for transient analysis of a heat-pipe-cooled space nuclear reactor power system (HPSR) was improved and validated in this study. The models improved mainly comprise: (1) An entire 2-D solid-core heat transfer model is established to analyze the accident conditions of core heat pipe failure and system heat sink loss. In this model, radial and axial Fourier heat conduction equations are used to divide the core into r-θ direction control volumes. The physical parameters of the material in the control volume are calculated according to the volume-weighted average. (2) By coupling the heat transfer limit model and the two-dimensional thermal resistance network model, the transient model of a heat pipe for HPMR system analysis is improved. (3) Conversion system models are established to simulate the system characteristics of the advanced HPMR concept, such as thermoelectric conversion, Stirling conversion, and the open Brayton conversion analysis model. Based on the improved models, the HPMR system analysis program TAPIRSD was developed, which was verified by experimental data of the separated conversion components and the ground nuclear test device KRUSTY. The maximum deviation of the power output predicted by the energy conversion model is less than 8%. The accident conditions of the KRUSTY tests, such as load change, core heat pipe failure, and heat sink loss accident, were studied by using TAPIRSD. The results show that the simulation results of the TAPIRSD code agree well with the experimental data of the KRUSTY prototype reactor. The maximum error between the TAPIRSD code prediction and the measured value of the core temperature under accident conditions is less than 10 K, and the maximum deviation is less than 2%. The results show that the developed code can predict the transient response process of the HPMR system well. At the same time, the accuracy and reliability of the improved model are proved. The TAPIRSD is suitable for system transient analysis of different types of HPMRs and provides an optional tool for the system safety characteristics analysis of HPMR.
Open AccessImprovement and Validation of the System Analysis Model and Code for Heat-Pipe-Cooled Microreactor
Heat-pipe-cooled microreactors (HPMR) use a passive high-temperature alkali metal heat pipe to directly transfer the heat of solid core to the hot end of the intermediate heat exchanger or thermoelectric conversion device, thus avoiding a single point failure. To analyze and evaluate the transient safety characteristics of an HPMR system under accident conditions, such as heat pipe failure in the core or a loss of system heat sink and other accidents, a previously developed model for transient analysis of a heat-pipe-cooled space nuclear reactor power system (HPSR) was improved and validated in this study. The models improved mainly comprise: (1) An entire 2-D solid-core heat transfer model is established to analyze the accident conditions of core heat pipe failure and system heat sink loss. In this model, radial and axial Fourier heat conduction equations are used to divide the core into r-θ direction control volumes. The physical parameters of the material in the control volume are calculated according to the volume-weighted average. (2) By coupling the heat transfer limit model and the two-dimensional thermal resistance network model, the transient model of a heat pipe for HPMR system analysis is improved. (3) Conversion system models are established to simulate the system characteristics of the advanced HPMR concept, such as thermoelectric conversion, Stirling conversion, and the open Brayton conversion analysis model. Based on the improved models, the HPMR system analysis program TAPIRSD was developed, which was verified by experimental data of the separated conversion components and the ground nuclear test device KRUSTY. The maximum deviation of the power output predicted by the energy conversion model is less than 8%. The accident conditions of the KRUSTY tests, such as load change, core heat pipe failure, and heat sink loss accident, were studied by using TAPIRSD. The results show that the simulation results of the TAPIRSD code agree well with the experimental data of the KRUSTY prototype reactor. The maximum error between the TAPIRSD code prediction and the measured value of the core temperature under accident conditions is less than 10 K, and the maximum deviation is less than 2%. The results show that the developed code can predict the transient response process of the HPMR system well. At the same time, the accuracy and reliability of the improved model are proved. The TAPIRSD is suitable for system transient analysis of different types of HPMRs and provides an optional tool for the system safety characteristics analysis of HPMR.
- Open Access
Development of a Performance Analysis Model for Free-Piston Stirling Power Convertor in Space Nuclear Reactor Power Systems
Space nuclear reactor power system (SNRPS) is a priority technical solution to meet the future space power requirement of high-power, low-mass, and long-life. The thermoelectric conversion subsystem is the key component of SNRPS, which greatly affects the performance, quality, and volume of SNRPS. Among all kinds of proposed thermoelectric conversion technologies, the free-piston Stirling power converter (FPSPC) has become a preferred conversion technology for small-scale advanced SNPRS due to its moderate waste heat emission temperature and high conversion efficiency, mainly composed of a linear alternator and free-piston Stirling engine (FPSE). For studying the performance of FPSPC, a quasi-steady flow thermodynamic cycle analysis model considering parasitic heat losses has been developed for FPSE. And then the performance analysis model for FPSPC has been established by coupling the thermodynamic cycle analysis model with the mechanical motion model of the piston and volt-ampere characteristic model of the linear alternator. Furthermore, the analysis model was compared and validated by the GPU-3 Stirling engine’s experimental data. The performance parameters of Component Test Power Converter (CTPT) FPSPC designed by NASA for SNRPS were also analyzed. The results show that the amplitudes position of CTPC displacer and piston are 15.1 mm and 11.2 mm, respectively. The corresponding average electric power output of CTPC is 17.316 kW. The input thermal power to the CTPT heater is 66.1 kW, leading to the converter efficiency of 26.2%. The average current and voltage of the CTPC alternator are 86.38 A and 193.15 V, respectively. Among all kinds of parasitic energy losses, the regenerator heat loss accounts for the largest proportion, with an average of about 12.7 kW. The effects of cooler and heater temperature on the performance of CTPC FPSPC were also studied.
Open AccessDevelopment of a Performance Analysis Model for Free-Piston Stirling Power Convertor in Space Nuclear Reactor Power Systems
Space nuclear reactor power system (SNRPS) is a priority technical solution to meet the future space power requirement of high-power, low-mass, and long-life. The thermoelectric conversion subsystem is the key component of SNRPS, which greatly affects the performance, quality, and volume of SNRPS. Among all kinds of proposed thermoelectric conversion technologies, the free-piston Stirling power converter (FPSPC) has become a preferred conversion technology for small-scale advanced SNPRS due to its moderate waste heat emission temperature and high conversion efficiency, mainly composed of a linear alternator and free-piston Stirling engine (FPSE). For studying the performance of FPSPC, a quasi-steady flow thermodynamic cycle analysis model considering parasitic heat losses has been developed for FPSE. And then the performance analysis model for FPSPC has been established by coupling the thermodynamic cycle analysis model with the mechanical motion model of the piston and volt-ampere characteristic model of the linear alternator. Furthermore, the analysis model was compared and validated by the GPU-3 Stirling engine’s experimental data. The performance parameters of Component Test Power Converter (CTPT) FPSPC designed by NASA for SNRPS were also analyzed. The results show that the amplitudes position of CTPC displacer and piston are 15.1 mm and 11.2 mm, respectively. The corresponding average electric power output of CTPC is 17.316 kW. The input thermal power to the CTPT heater is 66.1 kW, leading to the converter efficiency of 26.2%. The average current and voltage of the CTPC alternator are 86.38 A and 193.15 V, respectively. Among all kinds of parasitic energy losses, the regenerator heat loss accounts for the largest proportion, with an average of about 12.7 kW. The effects of cooler and heater temperature on the performance of CTPC FPSPC were also studied.