HTHaining Tang

Haining Tang

*This is an algorithmically generated author record based on publicly available information.

Haining Tang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Changpo Song

    School of Automation, Wuxi University, Wuxi 214105, China

    3 shared publications
  • Fengyong Sun

    Jiangsu Province Key Laboratory of Aerospace Power System, College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

    2 shared publications
  • Manxiang Gao

    Jiangsu Province Key Laboratory of Aerospace Power System, College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

    2 shared publications
  • Xingxing Fan

    Jiangsu Province Key Laboratory of Aerospace Power System, College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

    2 shared publications
  • Yong Wang

    Jiangsu Province Key Laboratory of Aerospace Power System, College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

    2 shared publications
  • Tianbin Jiang

    Xinjiang Lvfa Electric Power Energy Co., Ltd., Urumqi 830017, China

    1 shared publication

Latest Publications

  • Open Access

    Plant-Level Coordinated Frequency Support for Renewable Power Plants with Wind, PV, and Hybrid Energy Storage Using Model Predictive Control

    by Tianbin Jiang, Zhongming Gong, Wenbo Cao, Haining Tang, Changpo Song

    High penetration of inverter-interfaced renewable generation reduces power system inertia and increases the demand for fast plant-level frequency support. This paper proposes a model predictive control (MPC)-based coordinated frequency support strategy for renewable power plants integrating wind power, photovoltaic (PV) generation, and hybrid energy storage systems (HESSs). An equivalent grid frequency response model is first established and combined with aggregated dynamic models of wind, PV, and heterogeneous HESS units to develop a unified control-oriented state-space formulation. In this framework, renewable reserve limits, storage power constraints, and state-of-charge (SoC) dynamics are explicitly incorporated to characterize the time-varying feasible support capability of the plant. On this basis, the coordinated frequency support problem is formulated as a constrained receding-horizon optimization problem, in which frequency deviation suppression, plant-level supplementary power coordination, and HESS energy-state management are considered simultaneously. Simulation studies under step-change and random load disturbances demonstrate the effectiveness of the proposed strategy. Under the representative step-change disturbance, the maximum frequency deviation is limited to approximately 4.5×10−4 p.u., and the frequency rapidly recovers to a steady operating region. Under random load disturbances, the frequency deviation remains bounded within approximately ±1.0×10−3 p.u. Moreover, the SoC values of all heterogeneous storage units remain within the prescribed range of 0.3–0.7 p.u. throughout the support process. These results demonstrate that the proposed strategy achieves effective transient frequency support while maintaining coordinated active power allocation and feasible HESS energy-state operation.

  • Open Access

    Beyond Scale Variability: Dynamic Cross-Scale Modeling and Efficient Sparse Heads for Wind Turbine Blade Defect Detection

    by Xingxing Fan, Manxiang Gao, Yong Wang, Haining Tang, Fengyong Sun, Changpo Song

    Images of wind turbine blades captured by drones often feature complex backgrounds, and small targets such as minor defects or images have low resolution, leading to reduced recognition rates. To address environments with complex feature backgrounds, this paper proposes the PPS-MSDeim model. Based on the lightweight end-to-end detection framework DEIM-N, it introduces three core innovations to tackle the challenge of detecting small, irregular defects on wind turbine blades against complex backgrounds. First, we design an inverted multi-scale deep separable convolutional module (MDSC). After compressing channels via a bottleneck layer, it concurrently processes 3 × 3, 5 × 5, and 7 × 7 inverted deep separable convolutions. By first fusing channel information and then extracting multi-receiver-field spatial features, this approach enhances the ability to characterize morphologically variable defects while reducing computational overhead. The MDSC is then embedded into the backbone network HGNetv2. Second, we construct a Multi-Scale Feature Aggregation and Diffusion Pyramid Network (MFADPN). Through a Multi-Scale Feature Aggregation Module (MSFAM), it directly fuses features from layers P2 to P5, achieving deep integration of high-level semantics and low-level details. Combining dilated convolutions with expansion ratios of 1, 3, and 5 captures multi-level context, and a Sobel edge branch is introduced to enhance defect contours; subsequently, a feature diffusion operation is performed to distribute the enhanced features back to each level, shortening information paths and preventing signal decay; simultaneously, a high-resolution detection head is added to P2 and the P5 head is removed to improve sensitivity for small object detection. Finally, we propose the PPSformer module to replace the original Transformer encoding layer. It uses patch embedding to convert images into sequences and introduces a multi-head probabilistic sparse self-attention mechanism that focuses only on key-value pairs during attention computation. This design efficiently captures irregularly varying feature information and globally detects data anomalies induced by external defects. This study uses real engineering data sets, and the results show that PPS-MSDeim, based on DEIM, increased mAP@0.5 by 6.7%, reaching 95.1%. mAP@0.5–0.95 increased by 12.0%, reaching 70.1%. This indicates that the proposed method has a significant advantage in detecting defects in wind turbine blades.


  • Open Access

    Data-Efficient Insulator Defect Detection in Power Transmission Systems via Multi-Granularity Feature Learning and Latent Context-Aware Fusion

    by Xingxing Fan, Manxiang Gao, Yong Wang, Haining Tang, Fengyong Sun, Changpo Song

    Real-world power transmission inspection faces acute data scarcity and severe class imbalance, as defective insulator instances are exceptionally rare compared to normal samples. To enable robust defect detection under such constraints, we present MS-LaT—a backbone networkthat fuses multi-granularity feature learning with latent context-aware fusion. The architecture processes visual inputs through a streamlined pipeline: an input stage employing AdaptTeLU-augmented inverted multi-scale separable-residual convolutions to discern subtle local anomalies; a contextual reasoning stage powered by a Latent Transformer encoder with Multi-Head Latent Attention (MLA) for holistic scene understanding; and an output stage utilizing AdaptTeLU-refined inverted multi-scale convolutions to produce precise diagnostic decisions. Domain-adaptive batch normalization (AdaBN) is embedded to minimize cross-domain feature divergence, substantially boosting generalization across diverse operational environments. Research utilising real-world engineering datasets demonstrates the proposed method’s robust insulator defect detection capability in complex environments.