Zhihui Shan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhihui Shan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Fengzhang Luo
State Key Laboratory of Smart Power Distribution Equipment and System, Tianjin University, Tianjin 300072, China
2 shared publications - Qingwei Wang
Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518048, China
1 shared publication - Ruosong Hou
State Grid Hebei Economic Research Institute, Shijiazhuang 050000, China
1 shared publication - Wei Guo
State Grid Hebei Economic Research Institute, Shijiazhuang 050000, China
1 shared publication - Xiaolin Tan
State Grid Hebei Economic Research Institute, Shijiazhuang 050000, China
1 shared publication - Zhou Shu
Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518048, China
1 shared publication
Latest Publications
- Open Access
- 15 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (22) , 11319
Source-Load Complementarity-Guided Siting and Sizing of Soft Open Points in Multi-Region Distribution Networks
The increasing penetration of distributed renewable energy has intensified source-load mismatches and net-load fluctuations in distribution networks. Existing soft open point (SOP) planning methods mainly rely on network topology and electrical performance indicators, while interregional source-load complementarity is rarely explicitly considered in candidate-location selection. To address this gap, this paper proposes a source-load complementarity-guided SOP siting-and-sizing framework for multi-region distribution networks. A temporal complementarity coefficient and an aggregated fluctuation reduction coefficient are combined to evaluate and prioritize candidate interconnection boundaries. Subsequently, a bi-objective optimization model is developed to jointly determine SOP locations, capacities, and operating strategies while considering planning economics and regional net-load fluctuation mitigation. The ε-constraint method is employed to generate Pareto solutions, and a normalized maximum-distance criterion is adopted to identify a representative knee-point scheme. Case-study results indicate that the proposed framework can support candidate-location prioritization, while the selected compromise scheme achieves a favorable balance between economic performance and net-load fluctuation mitigation. The findings provide a practical reference for SOP planning in multi-region distribution networks.
- 15 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (22) , 11319
Open AccessSource-Load Complementarity-Guided Siting and Sizing of Soft Open Points in Multi-Region Distribution Networks
The increasing penetration of distributed renewable energy has intensified source-load mismatches and net-load fluctuations in distribution networks. Existing soft open point (SOP) planning methods mainly rely on network topology and electrical performance indicators, while interregional source-load complementarity is rarely explicitly considered in candidate-location selection. To address this gap, this paper proposes a source-load complementarity-guided SOP siting-and-sizing framework for multi-region distribution networks. A temporal complementarity coefficient and an aggregated fluctuation reduction coefficient are combined to evaluate and prioritize candidate interconnection boundaries. Subsequently, a bi-objective optimization model is developed to jointly determine SOP locations, capacities, and operating strategies while considering planning economics and regional net-load fluctuation mitigation. The ε-constraint method is employed to generate Pareto solutions, and a normalized maximum-distance criterion is adopted to identify a representative knee-point scheme. Case-study results indicate that the proposed framework can support candidate-location prioritization, while the selected compromise scheme achieves a favorable balance between economic performance and net-load fluctuation mitigation. The findings provide a practical reference for SOP planning in multi-region distribution networks.
- Open Access
Potential Assessment and Optimization Configuration Method for Flexible Interconnection of Distribution Transformer Areas
In the context of high penetration of distributed energy resources and new load integration, existing research primarily focuses on capacity optimization under pre-established interconnection structures, addressing issues such as uneven spatiotemporal distribution of loads and low equipment utilization in distribution transformer areas. However, these studies lack a planning-stage interconnection object selection mechanism. To address this, this paper proposes a planning-oriented flexible interconnection potential assessment and optimization configuration method for distribution transformer areas. First, a quantitative interconnection potential assessment model is developed, integrating load rate improvement after interconnection and geographical connection costs, enabling the ranking and selection of candidate transformer area combinations. On this basis, a flexible interconnection system optimization configuration model is established, aiming to minimize the overall system cost, and collaboratively optimizing converter and energy storage capacities. A case study of 20 distribution transformer areas in a certain city shows that the optimal transformer area combination increases the load factor from 64.6% to 79.4%, an improvement of 22.9%; when considering energy storage configuration, the total economic cost of the interconnection system is reduced by approximately 20.2% compared to the independent operation mode. The results validate the effectiveness of the proposed method in improving equipment utilization and reducing the system’s total lifecycle cost, providing decision support for flexible planning of urban distribution networks.
Open AccessPotential Assessment and Optimization Configuration Method for Flexible Interconnection of Distribution Transformer Areas
In the context of high penetration of distributed energy resources and new load integration, existing research primarily focuses on capacity optimization under pre-established interconnection structures, addressing issues such as uneven spatiotemporal distribution of loads and low equipment utilization in distribution transformer areas. However, these studies lack a planning-stage interconnection object selection mechanism. To address this, this paper proposes a planning-oriented flexible interconnection potential assessment and optimization configuration method for distribution transformer areas. First, a quantitative interconnection potential assessment model is developed, integrating load rate improvement after interconnection and geographical connection costs, enabling the ranking and selection of candidate transformer area combinations. On this basis, a flexible interconnection system optimization configuration model is established, aiming to minimize the overall system cost, and collaboratively optimizing converter and energy storage capacities. A case study of 20 distribution transformer areas in a certain city shows that the optimal transformer area combination increases the load factor from 64.6% to 79.4%, an improvement of 22.9%; when considering energy storage configuration, the total economic cost of the interconnection system is reduced by approximately 20.2% compared to the independent operation mode. The results validate the effectiveness of the proposed method in improving equipment utilization and reducing the system’s total lifecycle cost, providing decision support for flexible planning of urban distribution networks.