Charlotte C. Baker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charlotte C. Baker has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Michael Schwab
Department of Orthopaedic Surgery and Traumatology, HFR Cantonal Hospital, University of Fribourg, Fribourg, Switzerland
3 shared publications - Zachary M. Ricciardelli
Total Joint Specialists, Northside Hospital Forsyth, Cumming, GA 30041, USA
3 shared publications - Anita “Alex” Bradham
Total Joint Specialists, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, GA, USA
2 shared publications Courtney Levit
2 shared publicationsGeorge N. Guild
2 shared publicationsJoseph M. Schwab
2 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6343
Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty
Background/Objectives: Collared triple-tapered cementless femoral stems are designed to optimize metaphyseal fit, stability, and osseointegration following total hip arthroplasty (THA). This study evaluated 90-day revision and complication rates, short-term functional recovery, and operative characteristics of a modern collared triple-tapered stem in a same-day discharge ambulatory surgery center cohort. Methods: This retrospective cohort study reviewed 525 consecutive primary direct anterior THAs performed by 15 fellowship-trained arthroplasty surgeons at one group operating across several ASCs between September 2024 and August 2025. Ninety-day all-cause revision, stem-specific revision, periprosthetic fracture, and other early postoperative complications were evaluated. Kaplan–Meier estimates were used to account for variable follow-up within the 90 days. PROMs (HOOS-JR, FJS, VR-12) were collected preoperatively and at 12 weeks. Operative time was evaluated using within-surgeon analyses restricted to surgeons who used both an automated impaction device (AID) and manual impaction. Results: At a mean effective follow-up of 110 ± 39 days, the 90-day Kaplan–Meier revision-free estimate was 99.62% for all-cause revision and 99.81% for stem revision. Two patients (0.4%) underwent revision (one Vancouver B2 fracture; one infection treated with DAIR with stem retention). The early periprosthetic fracture rate was 0.2%. Five patients (1.0%) experienced dislocation, all of whom were managed with closed reduction. HOOS-JR improved by 28.7 points and FJS by 41.9 points at 12 weeks (both p < 0.0001), with 84.2% and 85.8% MCID achievement, respectively. Seven surgeons used both techniques, contributing 384 AID and 58 manual cases to the within-surgeon analysis. AID use was not associated with operative time after accounting for surgeon (adjusted difference, 0.18 min; 95% CI, −2.04 to 2.39; p = 0.8764). Conclusions: This collared, triple-tapered cementless stem was associated with low 90-day revision and complication rates and clinically meaningful short-term functional improvement in a same-day discharge ambulatory population. AID use was not associated with operative time after accounting for surgeon, although the study was not powered to compare uncommon complications between impaction methods.
- 17 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6343
Open AccessEarly Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty
Background/Objectives: Collared triple-tapered cementless femoral stems are designed to optimize metaphyseal fit, stability, and osseointegration following total hip arthroplasty (THA). This study evaluated 90-day revision and complication rates, short-term functional recovery, and operative characteristics of a modern collared triple-tapered stem in a same-day discharge ambulatory surgery center cohort. Methods: This retrospective cohort study reviewed 525 consecutive primary direct anterior THAs performed by 15 fellowship-trained arthroplasty surgeons at one group operating across several ASCs between September 2024 and August 2025. Ninety-day all-cause revision, stem-specific revision, periprosthetic fracture, and other early postoperative complications were evaluated. Kaplan–Meier estimates were used to account for variable follow-up within the 90 days. PROMs (HOOS-JR, FJS, VR-12) were collected preoperatively and at 12 weeks. Operative time was evaluated using within-surgeon analyses restricted to surgeons who used both an automated impaction device (AID) and manual impaction. Results: At a mean effective follow-up of 110 ± 39 days, the 90-day Kaplan–Meier revision-free estimate was 99.62% for all-cause revision and 99.81% for stem revision. Two patients (0.4%) underwent revision (one Vancouver B2 fracture; one infection treated with DAIR with stem retention). The early periprosthetic fracture rate was 0.2%. Five patients (1.0%) experienced dislocation, all of whom were managed with closed reduction. HOOS-JR improved by 28.7 points and FJS by 41.9 points at 12 weeks (both p < 0.0001), with 84.2% and 85.8% MCID achievement, respectively. Seven surgeons used both techniques, contributing 384 AID and 58 manual cases to the within-surgeon analysis. AID use was not associated with operative time after accounting for surgeon (adjusted difference, 0.18 min; 95% CI, −2.04 to 2.39; p = 0.8764). Conclusions: This collared, triple-tapered cementless stem was associated with low 90-day revision and complication rates and clinically meaningful short-term functional improvement in a same-day discharge ambulatory population. AID use was not associated with operative time after accounting for surgeon, although the study was not powered to compare uncommon complications between impaction methods.
- Open Access
- 13 August 2026
- Published by Elsevier in Arthroplasty Today
- Vol. 40
Extended Oral Antibiotics After Primary Total Hip and Knee Arthroplasty in an Ambulatory Surgery Center: A Bayesian Threshold and Cost-Effectiveness Analysis
- 13 August 2026
- Published by Elsevier in Arthroplasty Today
- Vol. 40
Open AccessExtended Oral Antibiotics After Primary Total Hip and Knee Arthroplasty in an Ambulatory Surgery Center: A Bayesian Threshold and Cost-Effectiveness Analysis
- 1 July 2026
- Published by SAGE Publications in HIP International
Short-term survivorship of a novel acetabular component with a combination of non-locking and variable-angle locking screws in complex acetabular reconstruction
Background: Highly porous shells have been used with success to manage acetabular bone loss in complex (cTHA) and revision total hip arthroplasty (rTHA) for nearly 2 decades. Recently, a 3D-printed titanium shell with locking screw technology was developed. Our study sought to evaluate the survivorship of the novel variable-angle locking screw (VALS) acetabular component. Methods: This multicentre retrospective study analysed cTHA ( n = 61) and rTHA (n = 145) using the VALS component. 206 patients were included in the final analysis, with a mean age of 65.1 (range 15–95) years, mean BMI of 30.9 ± 7.3 kg/m 2 , and 60.2% women. Mean follow-up was 1.1 (range 0.1–5.1) years. The Kaplan-Meier analysis was utilised to assess implant survivorship and reoperation. Results: Of the 206 included cases, 20 were reoperations, 9 of which involved acetabular revision. The 1-year and 2-year acetabular component revision-free survivorship was 95 and 94%, and all-cause reoperation was 90 and 86%, respectively. Importantly, there were only 2 cases of aseptic acetabular loosening identified. Conclusions: The novel VALS component demonstrated encouraging early survivorship with a low incidence of complications when utilised in complex acetabular reconstruction. Further studies are warranted to assess long-term survivorship.
- 1 July 2026
- Published by SAGE Publications in HIP International
Short-term survivorship of a novel acetabular component with a combination of non-locking and variable-angle locking screws in complex acetabular reconstruction
Background: Highly porous shells have been used with success to manage acetabular bone loss in complex (cTHA) and revision total hip arthroplasty (rTHA) for nearly 2 decades. Recently, a 3D-printed titanium shell with locking screw technology was developed. Our study sought to evaluate the survivorship of the novel variable-angle locking screw (VALS) acetabular component. Methods: This multicentre retrospective study analysed cTHA ( n = 61) and rTHA (n = 145) using the VALS component. 206 patients were included in the final analysis, with a mean age of 65.1 (range 15–95) years, mean BMI of 30.9 ± 7.3 kg/m 2 , and 60.2% women. Mean follow-up was 1.1 (range 0.1–5.1) years. The Kaplan-Meier analysis was utilised to assess implant survivorship and reoperation. Results: Of the 206 included cases, 20 were reoperations, 9 of which involved acetabular revision. The 1-year and 2-year acetabular component revision-free survivorship was 95 and 94%, and all-cause reoperation was 90 and 86%, respectively. Importantly, there were only 2 cases of aseptic acetabular loosening identified. Conclusions: The novel VALS component demonstrated encouraging early survivorship with a low incidence of complications when utilised in complex acetabular reconstruction. Further studies are warranted to assess long-term survivorship.
- Open Access
- 10 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2110
A Modern Collared Cementless Femoral Stem for the Arthroplasty Treatment of Femoral Neck Fractures
Background/Objectives: For femoral neck fractures (FNFs) treated with hip arthroplasty, cemented femoral fixation is frequently recommended due to its association with reduced early perioperative fracture and reoperation rates. However, newer-generation collared, cementless triple-tapered (CCTT) stems may present benefits compared with conventional press-fit designs. This study sought to assess 30-day survivorship of a CCTT stem in patients undergoing hip arthroplasty for FNF via the direct anterior approach (DAA). Methods: We conducted a retrospective review of all patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for displaced FNF from 2019 to 2023. All procedures were performed through the DAA using a hydroxyapatite-coated CCTT femoral stem. The primary outcome was 30-day stem survival. Secondary outcomes included reoperation, stem revision, complications, readmission, and radiographic outcomes including intraoperative and postoperative periprosthetic fracture and subsidence. Results: A total of 184 patients were included (mean age 76.1 ± 10.0; 70.1% women). THA was performed in 77.7% and HA in 22.3%. At 30 days, no stems required revision. The 30-day reoperation rate was 3.5% (5/184). There were four intraoperative fractures: 3 (1.6%) Vancouver AG and 1 (0.5%) calcar. Postoperatively within 3 months, seven fractures occurred: five (2.7%) Vancouver AG and two (1.1%) Vancouver B1. Conclusions: Use of a modern CCTT femoral stem for FNF demonstrated excellent early survivorship with low rates of intraoperative and postoperative periprosthetic fracture, comparable to published outcomes of cemented fixation. These findings suggest that this stem design may represent a safe and efficient alternative to cemented femoral fixation in FNF. Further studies are warranted to evaluate mid- and long-term outcomes.
- 10 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (6) , 2110
Open AccessA Modern Collared Cementless Femoral Stem for the Arthroplasty Treatment of Femoral Neck Fractures
Background/Objectives: For femoral neck fractures (FNFs) treated with hip arthroplasty, cemented femoral fixation is frequently recommended due to its association with reduced early perioperative fracture and reoperation rates. However, newer-generation collared, cementless triple-tapered (CCTT) stems may present benefits compared with conventional press-fit designs. This study sought to assess 30-day survivorship of a CCTT stem in patients undergoing hip arthroplasty for FNF via the direct anterior approach (DAA). Methods: We conducted a retrospective review of all patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for displaced FNF from 2019 to 2023. All procedures were performed through the DAA using a hydroxyapatite-coated CCTT femoral stem. The primary outcome was 30-day stem survival. Secondary outcomes included reoperation, stem revision, complications, readmission, and radiographic outcomes including intraoperative and postoperative periprosthetic fracture and subsidence. Results: A total of 184 patients were included (mean age 76.1 ± 10.0; 70.1% women). THA was performed in 77.7% and HA in 22.3%. At 30 days, no stems required revision. The 30-day reoperation rate was 3.5% (5/184). There were four intraoperative fractures: 3 (1.6%) Vancouver AG and 1 (0.5%) calcar. Postoperatively within 3 months, seven fractures occurred: five (2.7%) Vancouver AG and two (1.1%) Vancouver B1. Conclusions: Use of a modern CCTT femoral stem for FNF demonstrated excellent early survivorship with low rates of intraoperative and postoperative periprosthetic fracture, comparable to published outcomes of cemented fixation. These findings suggest that this stem design may represent a safe and efficient alternative to cemented femoral fixation in FNF. Further studies are warranted to evaluate mid- and long-term outcomes.