Tigran G. Gevorkyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tigran G. Gevorkyan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Nikolaevich Pronichev
National Research Nuclear University “MEPhI”, Moscow, Russian Federation
1 shared publication - Alexey Lazarev
Bioinformatics and Big Data Analysis Laboratory, N.N. Blokhin National Medical Research Center for Oncology, Moscow 115478, Russia
1 shared publication - Anna Borunova
N. N. Blokhin National Medical Research Center of Oncology, Ministry of Health of Russia, 24 Kashirskoe Shosse, 115522 Moscow, Russia
1 shared publication - Arsenii Litvinov
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication Aydar Akhmetzyanov
LLC “GlavGidroStroy”, 17-Y Mar'iny Roshchi Proezd, 4, Building 1, Room 18/19, 127521, Moscow, Russia;, Russia
1 shared publication- Egor Ushakov
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication
Latest Publications
- Open Access
Evaluation of Computational Neoantigen Prioritization Strategies for Personalized Cancer Vaccines
Background: Identification of immunogenic neoantigens remains one of the major computational bottlenecks limiting the development of effective personalized cancer vaccines. Although various computational methods have been proposed for neoantigen discovery, there is little independent evidence regarding which approaches most effectively prioritize vaccine candidates using experimentally validated datasets. We focused on an independent multi-cohort benchmark of widely used neoantigen discovery pipelines and neoantigen scoring tools using publicly available datasets with experimentally validated immunogenic peptide–Major Histocompatibility complexes (MHC). Methods: In order to evaluate computational strategies used for selection of candidate vaccine peptides, five end-to-end neoantigen prediction pipelines and seven neoantigen scoring and prioritization tools were independently benchmarked using experimentally validated neoantigen datasets. End-to-end pipelines were evaluated on the TESLA cohort using raw WES and RNA-seq data from five patients, while individual prediction tools were additionally assessed on the TESLA, NCI, and HiTIDE validation cohorts comprising experimentally verified immunogenic and non-immunogenic peptide–MHC complexes. Results: NeoHunter achieved the highest overall recovery of experimentally validated neoantigens among the evaluated pipelines, while the scoring and prioritization tools NetMHCpan, MixMHCpred, and MHCFlurry generally showed the strongest ranking performance, although their relative performance varied substantially between datasets and patients. Precision–recall, average precision, and top K analyses demonstrated that no single predictor consistently dominated across cohorts and revealed a clear trade-off between candidate list size, precision, and recovery of validated neoantigens. Analysis of clinically relevant candidate selection thresholds demonstrated that restricting vaccine design to only the highest-ranked peptides substantially reduces sensitivity, whereas broader candidate selection improves recovery at the expense of increased experimental burden. Conclusions: These findings provide practical recommendations for computational selection of vaccine targets and highlight current limitations that must be addressed to improve the success of personalized neoantigen-based vaccines.
Open AccessEvaluation of Computational Neoantigen Prioritization Strategies for Personalized Cancer Vaccines
Background: Identification of immunogenic neoantigens remains one of the major computational bottlenecks limiting the development of effective personalized cancer vaccines. Although various computational methods have been proposed for neoantigen discovery, there is little independent evidence regarding which approaches most effectively prioritize vaccine candidates using experimentally validated datasets. We focused on an independent multi-cohort benchmark of widely used neoantigen discovery pipelines and neoantigen scoring tools using publicly available datasets with experimentally validated immunogenic peptide–Major Histocompatibility complexes (MHC). Methods: In order to evaluate computational strategies used for selection of candidate vaccine peptides, five end-to-end neoantigen prediction pipelines and seven neoantigen scoring and prioritization tools were independently benchmarked using experimentally validated neoantigen datasets. End-to-end pipelines were evaluated on the TESLA cohort using raw WES and RNA-seq data from five patients, while individual prediction tools were additionally assessed on the TESLA, NCI, and HiTIDE validation cohorts comprising experimentally verified immunogenic and non-immunogenic peptide–MHC complexes. Results: NeoHunter achieved the highest overall recovery of experimentally validated neoantigens among the evaluated pipelines, while the scoring and prioritization tools NetMHCpan, MixMHCpred, and MHCFlurry generally showed the strongest ranking performance, although their relative performance varied substantially between datasets and patients. Precision–recall, average precision, and top K analyses demonstrated that no single predictor consistently dominated across cohorts and revealed a clear trade-off between candidate list size, precision, and recovery of validated neoantigens. Analysis of clinically relevant candidate selection thresholds demonstrated that restricting vaccine design to only the highest-ranked peptides substantially reduces sensitivity, whereas broader candidate selection improves recovery at the expense of increased experimental burden. Conclusions: These findings provide practical recommendations for computational selection of vaccine targets and highlight current limitations that must be addressed to improve the success of personalized neoantigen-based vaccines.
- Open Access
- 31 July 2026
- Published by MDPI AG in Informatics
- Vol. 13 (8) , 125
Optimizing the Mammography AI Pipeline: From Data Filtering to Vision-Language Models
The performance of AI solutions in mammography is largely determined by data quality, preprocessing methods, and augmentation strategies. However, systematic evaluation of these factors for models trained on aggregated multicenter datasets remains underexplored. This article presents a comparative assessment of the effects of different stages of the training pipeline on the final diagnostic accuracy. Using a pooled dataset (VinDr-Mammo, INBreast, CMMD, CBIS-DDSM), we evaluated each pipeline step—from filtering to architecture selection (EfficientNet-B3, CLIP). External testing was conducted on the MosMed database. Among the tested preprocessing steps, filtering the darkest 5% of images proved most effective. For EfficientNet-B3, optimal geometric and photometric augmentations increased test AUROC on the prepared MosMed test set from 0.844 to 0.900. Domain-specific pretraining and high resolution yielded the best performance: Mammo-CLIP achieved an AUROC of 0.949 ± 0.012, and EfficientNet-B3 reached 0.934 ± 0.013. Overall, this study developed a standardized pipeline that includes sequential data filtering and harmonization, augmentation optimization, and architecture selection. This approach ensures reliable and reproducible results for automated mammogram classification.
- 31 July 2026
- Published by MDPI AG in Informatics
- Vol. 13 (8) , 125
Open AccessOptimizing the Mammography AI Pipeline: From Data Filtering to Vision-Language Models
The performance of AI solutions in mammography is largely determined by data quality, preprocessing methods, and augmentation strategies. However, systematic evaluation of these factors for models trained on aggregated multicenter datasets remains underexplored. This article presents a comparative assessment of the effects of different stages of the training pipeline on the final diagnostic accuracy. Using a pooled dataset (VinDr-Mammo, INBreast, CMMD, CBIS-DDSM), we evaluated each pipeline step—from filtering to architecture selection (EfficientNet-B3, CLIP). External testing was conducted on the MosMed database. Among the tested preprocessing steps, filtering the darkest 5% of images proved most effective. For EfficientNet-B3, optimal geometric and photometric augmentations increased test AUROC on the prepared MosMed test set from 0.844 to 0.900. Domain-specific pretraining and high resolution yielded the best performance: Mammo-CLIP achieved an AUROC of 0.949 ± 0.012, and EfficientNet-B3 reached 0.934 ± 0.013. Overall, this study developed a standardized pipeline that includes sequential data filtering and harmonization, augmentation optimization, and architecture selection. This approach ensures reliable and reproducible results for automated mammogram classification.
- Open Access
- 11 March 2026
- Published by MDPI AG in Preprints.org
The Electronic Health Record-Based Artificial Intelligence Model for Predicting Long-Term Outcomes After Radical Surgery for Colorectal Cancer
Background: Accurate prediction of outcomes in colorectal cancer (CRC) is essential for personalized treatment. Conventional prognostic tools, including TNM staging, have limited accuracy. Machine learning (ML) may better capture complex prognostic patterns. Methods: In a retrospective multicenter cohort of 7,253 non-metastatic CRC patients after radical surgery, we compared prognostic accuracy for predicting recurrence and mortality using: a baseline TNM stage model; a logistic regression model with six clinicopatho-logical variables; and ML algorithms (Logistic Regression, Random Forest, XGBoost, LightGBM, CatBoost) with hyperparameter optimization (Optuna) and iterative feature selection. Binary outcomes (recurrence and all-cause mortality at 1 and 3 years) were used for ML training. Performance was assessed using area under the ROC curve (AUC). Results: The stage-only model showed poor discrimination (weighted AUC: 0.541 for mortality, 0.528 for recurrence). Logistic regression improved predictions (AUC: 0.759 and 0.645, respectively). Among ML models, CatBoost achieved the best performance. After iterative feature selection, the optimized CatBoost model utilizing 17 clinical var-iables demonstrated superior cross-validated AUCs of 0.81 for mortality and 0.84 for recurrence, consistently outperforming both baseline models across all time horizons. External validation on 1,452 held-out patients confirmed robustness with AUCs of 0.83 for mortality and 0.91 for recurrence. Conclusion: An optimized CatBoost model significantly outperforms traditional TNM staging and logistic regression in predicting recurrence and mortality in CRC using 17 routinely available variables. This parsimonious, data-driven tool offers improved individualized risk assessment for guiding post-operative man-agement. Prospective validation is warranted.
- 11 March 2026
- Published by MDPI AG in Preprints.org
Open AccessThe Electronic Health Record-Based Artificial Intelligence Model for Predicting Long-Term Outcomes After Radical Surgery for Colorectal Cancer
Background: Accurate prediction of outcomes in colorectal cancer (CRC) is essential for personalized treatment. Conventional prognostic tools, including TNM staging, have limited accuracy. Machine learning (ML) may better capture complex prognostic patterns. Methods: In a retrospective multicenter cohort of 7,253 non-metastatic CRC patients after radical surgery, we compared prognostic accuracy for predicting recurrence and mortality using: a baseline TNM stage model; a logistic regression model with six clinicopatho-logical variables; and ML algorithms (Logistic Regression, Random Forest, XGBoost, LightGBM, CatBoost) with hyperparameter optimization (Optuna) and iterative feature selection. Binary outcomes (recurrence and all-cause mortality at 1 and 3 years) were used for ML training. Performance was assessed using area under the ROC curve (AUC). Results: The stage-only model showed poor discrimination (weighted AUC: 0.541 for mortality, 0.528 for recurrence). Logistic regression improved predictions (AUC: 0.759 and 0.645, respectively). Among ML models, CatBoost achieved the best performance. After iterative feature selection, the optimized CatBoost model utilizing 17 clinical var-iables demonstrated superior cross-validated AUCs of 0.81 for mortality and 0.84 for recurrence, consistently outperforming both baseline models across all time horizons. External validation on 1,452 held-out patients confirmed robustness with AUCs of 0.83 for mortality and 0.91 for recurrence. Conclusion: An optimized CatBoost model significantly outperforms traditional TNM staging and logistic regression in predicting recurrence and mortality in CRC using 17 routinely available variables. This parsimonious, data-driven tool offers improved individualized risk assessment for guiding post-operative man-agement. Prospective validation is warranted.
- 1 January 2026
- Published by Publishing house "Radiotekhnika" in Biomedical Radioelectronics
- p. 50-54
Artificial intelligence in flow cytometry systems: a method to increase the processing speed of big data. Problems and solutions
The development of the paper addresses the interdisciplinary challenge of accelerating data processing for flow cytometry. Traditional use of the pandas library in Python is limited by sequential calculations: processing 500 000 leukocyte cells takes 15 seconds. This long waiting time causes user discomfort and may lead to medical errors. The aim of the study is to develop an original method for increasing processing speed using parallel calculations, building on the authors’ previous work on leukocyte population recognition. The approach employs algorithms from the Ray distributed computing framework and the modin. pandas library. Experiments on clinical laboratory equipment confirm the solution’s effectiveness compared to traditional pandas algorithms. The use of the developed method reduced the processing time for 500 000 cells by 11 times, using data from an open Internet source. The method is scalable for medical diagnostics, treatment, forecasting, and artificial intelligence systems.
- 1 January 2026
- Published by Publishing house "Radiotekhnika" in Biomedical Radioelectronics
- p. 50-54
Artificial intelligence in flow cytometry systems: a method to increase the processing speed of big data. Problems and solutions
The development of the paper addresses the interdisciplinary challenge of accelerating data processing for flow cytometry. Traditional use of the pandas library in Python is limited by sequential calculations: processing 500 000 leukocyte cells takes 15 seconds. This long waiting time causes user discomfort and may lead to medical errors. The aim of the study is to develop an original method for increasing processing speed using parallel calculations, building on the authors’ previous work on leukocyte population recognition. The approach employs algorithms from the Ray distributed computing framework and the modin. pandas library. Experiments on clinical laboratory equipment confirm the solution’s effectiveness compared to traditional pandas algorithms. The use of the developed method reduced the processing time for 500 000 cells by 11 times, using data from an open Internet source. The method is scalable for medical diagnostics, treatment, forecasting, and artificial intelligence systems.