Fabiana Antenucci

Fabiana Antenucci

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabiana Antenucci has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinically Robust Deep Learning for Contrast-Enhanced Mammography: Multicenter Evaluation Across Convolutional Neural Network Architectures

    by Roberta Fusco, Vincenza Granata, Paolo Vallone, Teresa Petrosino, Maria Daniela Iasevoli, Roberta Galdiero, Mauro Mattace Raso, Davide Pupo, Filippo Tovecci, Annamaria Porto, et al.

    Background: This study investigates the impact of anatomically constrained preprocessing and deep learning architecture selection on benign versus malignant breast lesion classification in contrast-enhanced mammography (CEM), with the goal of improving robustness and clinical reliability across heterogeneous data sources. Methods: In this retrospective multicenter study, CEM images from 300 patients (314 lesions) were combined with 1003 publicly available CEM images, yielding a total of 1120 breast cases. Automatic breast segmentation was performed using the LIBRA framework to generate breast-mask images. Eleven deep learning models, including classical convolutional neural networks, attention-based networks, hybrid convolutional neural networks (CNNs), Transformer architectures, and mammography-specific models, were trained and evaluated using both original DICOM images and breast-mask inputs. Performance was assessed using accuracy, balanced accuracy, sensitivity, specificity, AUROC, and AUPRC on cross-validation and independent test sets. Hyperparameter optimization was conducted for the best-performing architecture. Results: Models trained on breast-mask images consistently outperformed those trained on original DICOM images across all architectures and metrics, with AUROC improvements ranging from +0.06 to +0.21. Among all models, ResNet50 trained on breast-mask images achieved the best performance (AUROC = 0.931; AUPRC = 0.933; balanced accuracy = 0.834), further improved after optimization (balanced accuracy = 0.886; sensitivity = 0.842; specificity = 0.930). Classical CNN architectures demonstrated performance comparable to or exceeding that of more complex hybrid CNN–Transformer models when anatomically focused preprocessing and rigorous optimization were applied. Conclusions: Anatomically constrained preprocessing through breast-mask segmentation substantially enhances deep learning performance and stability in CEM-based breast lesion classification. These findings indicate that input representation quality and training optimization are critical determinants of clinically relevant performance, often outweighing architectural complexity, and may support more reliable AI-assisted decision support in CEM workflows.


  • Open Access

    Engineering the Image Representation for Deep Learning in Contrast-Enhanced Mammography: A Systematic Analysis of Preprocessing and Anatomical Masking

    by Roberta Fusco, Vincenza Granata, Paolo Vallone, Teresa Petrosino, Maria Daniela Iasevoli, Mauro Mattace Raso, Davide Pupo, Piero Trovato, Igino Simonetti, Paolo Pariante, et al.

    Deep-learning models applied to contrast-enhanced mammography (CEM) are known to be highly sensitive to the input image representation. However, preprocessing is often treated as a secondary step and rarely analyzed as an independent design variable. In this work, we present a systematic engineering analysis of a deterministic, label-independent preprocessing pipeline for CEM images. The pipeline integrates intensity normalization, global histogram matching, local contrast enhancement, denoising, and anatomically constrained breast masking. Using a controlled experimental design, identical deep-learning architectures were trained under different input representations to isolate the impact of preprocessing on classification performance and stability. Across convolutional neural network architectures, anatomically constrained preprocessing consistently improves discrimination performance, reduces variability across cross-validation folds, and enhances training stability. Breast mask-based representations demonstrate substantial gains in AUROC and AUPRC compared to raw DICOM inputs. These findings highlight image preprocessing as a first-class engineering component in medical AI pipelines. Breast masking significantly improves robustness and generalization, independently of network architecture complexity. From a clinical perspective, improving model robustness and sensitivity to malignant lesions may contribute to more reliable AI-assisted decision support in contrast-enhanced mammography, particularly in settings characterized by acquisition variability and heterogeneous patient populations.