MKM. Shahrul Amir Kamarulzaman

M. Shahrul Amir Kamarulzaman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


M. Shahrul Amir Kamarulzaman has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Condition and Position Estimation Using Spatial Ultrasound and Machine Learning

    by M. Shahrul Amir Kamarulzaman, Shun Sato, Yuto Yasuda, Ryotaro Ohara, Shintaro Izumi, Hiroshi Kawaguchi

    This study addresses the significant risk of bathroom-related injuries, often exacerbated by slippery surfaces and delays in accident detection, particularly as individuals frequently bathe unattended. Traditional accident detection methods, including those based on radio waves, optical sensors, and cameras, have inherent limitations. Although previous research has explored beamforming with low-cost ultrasound array sensors for object detection, its considerable computational load necessitates alternative approaches, such as machine learning. This paper presents a novel position and condition estimation method employing a Transformer-based model coupled with ultrasound array sensors tailored for bathroom environments. The proposed model architecture incorporates an encoder and two distinct decoders to generate binary segmentation masks and depth estimations, complemented by a multilayer perceptron classification block for condition estimation. The model was trained on binary masks and depth images acquired from a depth camera. Input signals received at 227 kHz are processed through cross-correlation with 25 kHz transmitted signals, followed by downsampling. The performance evaluation was conducted in two areas: bathtub and general washroom. In the bathtub area, condition estimation achieved 97.5 ± 2.0% accuracy, whereas position estimation yielded a mean absolute error (MAE) of 11.9 ± 2.9 cm and an intersection over union (IoU) of 0.735 ± 0.022. Similarly, for the washroom area, condition estimation accuracy was 96.5 ± 0.8%, with position estimation resulting in an MAE of 14.1 ± 2.0 cm and an IoU of 0.656 ± 0.023. Notably, In the context of critical incident detection, the recall rates for drowning and falls were exceptionally high, exceeding 99.3 ± 1.5 and 99.5 ± 1.0%, respectively. These results demonstrate the significant potential and effectiveness of the proposed method for robust accident detection within bathroom environments.

  • Open Access

    Conformer-Based Sound Event Detection for Bathroom Activity Monitoring

    by M. Shahrul Amir Kamarulzaman, Koki Mori, Takayuki Genda, Shun Sato, Ryotaro Ohara, Shintaro Izumi, Hiroshi Kawaguchi