Karla Nogueira Matos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Karla Nogueira Matos has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hugo Henrique dos Santos Dantas Guimarães
Department of Restorative Dentistry Federal University of Minas Gerais Belo Horizonte Minas Gerais Brazil
11 shared publications - Leonardo Matos de Faria Almeida
Department of Restorative Dentistry, São Judas Tadeu University, São Paulo, SP, Brazil
3 shared publications Marcos de Faria Almeida
3 shared publications- Pedro Vitor dos Santos Sobrinho
Department of Restorative Dentistry, Catholic University of Brasília, Brasília, DF, Brazil
3 shared publications - Celso Luiz Caldeira
Universidade de São Paulo, Brazil
2 shared publications - Giovanna Fontgalland Ferreira
Biophotonics-medicine Posgradate Program, Universidade Nove de Julho (UNINOVE), São Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by Wiley in European Journal of Oral Sciences
Artificial intelligence for facial soft‐tissue landmark localization, measurement, and classification in orthodontics: A systematic review
This systematic review provides a broad overview of three distinct applications of artificial intelligence (AI) in facial soft‐tissue assessment: landmark localization, automated facial measurement, and classification of soft‐tissue conditions in orthodontic and dentofacial evaluation. PubMed, Embase, Scopus, Web of Science, Cochrane Library, ClinicalTrials.gov, Google Scholar, and Open Science Framework were searched. Studies using 2D facial photographs, 3D facial scans, or AI‐generated facial models were included. Risk of bias was assessed with an adapted QUADAS‐2 tool and certainty of evidence with GRADE. The protocol was registered in PROSPERO (CRD420261452521). Fifteen studies were included. Landmark‐localization performance varied substantially by imaging modality, landmark definition, data set, reference standard, and error metric; central and anatomically well‐defined landmarks were generally more accurate than peripheral or subjective points. Agreement for AI‐derived measurements ranged from poor to excellent, with ICCs of approximately 0.01–0.984. Classification accuracy ranged from approximately 0.83 to 0.98, with AUCs up to 0.98. Given only two narrowly scoped classification studies, these findings should be considered exploratory and hypothesis‐generating rather than broadly generalizable. Because of substantial methodological heterogeneity, findings were synthesized qualitatively. Current evidence supports AI as an adjunctive tool, but routine clinical implementation requires robust external validation and clinician oversight. PROSPERO registration: CRD420261452521
- 22 October 2026
- Published by Wiley in European Journal of Oral Sciences
Open AccessArtificial intelligence for facial soft‐tissue landmark localization, measurement, and classification in orthodontics: A systematic review
This systematic review provides a broad overview of three distinct applications of artificial intelligence (AI) in facial soft‐tissue assessment: landmark localization, automated facial measurement, and classification of soft‐tissue conditions in orthodontic and dentofacial evaluation. PubMed, Embase, Scopus, Web of Science, Cochrane Library, ClinicalTrials.gov, Google Scholar, and Open Science Framework were searched. Studies using 2D facial photographs, 3D facial scans, or AI‐generated facial models were included. Risk of bias was assessed with an adapted QUADAS‐2 tool and certainty of evidence with GRADE. The protocol was registered in PROSPERO (CRD420261452521). Fifteen studies were included. Landmark‐localization performance varied substantially by imaging modality, landmark definition, data set, reference standard, and error metric; central and anatomically well‐defined landmarks were generally more accurate than peripheral or subjective points. Agreement for AI‐derived measurements ranged from poor to excellent, with ICCs of approximately 0.01–0.984. Classification accuracy ranged from approximately 0.83 to 0.98, with AUCs up to 0.98. Given only two narrowly scoped classification studies, these findings should be considered exploratory and hypothesis‐generating rather than broadly generalizable. Because of substantial methodological heterogeneity, findings were synthesized qualitatively. Current evidence supports AI as an adjunctive tool, but routine clinical implementation requires robust external validation and clinician oversight. PROSPERO registration: CRD420261452521
- Open Access
- 27 September 2026
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 16 (6)
Conversational artificial intelligence compared with orthodontic reference standards for orthodontic information: A systematic review of accuracy, readability, safety, and certainty of evidence
- 27 September 2026
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 16 (6)
Open AccessConversational artificial intelligence compared with orthodontic reference standards for orthodontic information: A systematic review of accuracy, readability, safety, and certainty of evidence
- Open Access
- 5 September 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 214
Antimicrobial photodynamic therapy mediated by phenothiazine photosensitizers against Candida albicans and Candida auris: a systematic review
Fungal infections caused by Candida albicans and Candida auris represent an increasing clinical challenge, particularly due to biofilm formation and rising antifungal resistance. Antimicrobial photodynamic therapy (aPDT) has emerged as a potential alternative strategy, with phenothiazine-based photosensitizers being among the most extensively investigated compounds. This systematic review aimed to evaluate the application of phenothiazine-mediated aPDT in in vitro studies against C. albicans and C. auris . A comprehensive search was conducted in PubMed, Embase, and Scopus, including studies published within the last 10 years. Forty in vitro studies met the eligibility criteria and were synthesized descriptively due to substantial methodological heterogeneity. Overall, aPDT was associated with reductions in fungal viability, with generally greater effects reported in planktonic models compared with biofilms. Methylene blue was the most frequently investigated photosensitizer, applied across a broad range of concentrations and dosimetric parameters, resulting in variable antifungal responses. Other phenothiazine derivatives, including toluidine blue O, dimethyl methylene blue, new methylene blue, and S137, were also associated with antifungal activity under specific experimental conditions but remain comparatively underexplored. Studies involving C. auris were less frequent and suggested lower susceptibility compared with C. albicans , particularly in biofilm models. Given the substantial variability in experimental protocols, especially regarding photosensitizer concentration, light parameters, and biofilm maturation, the findings should be interpreted with caution and limit direct comparison across studies. These findings support the antifungal potential of phenothiazine-mediated aPDT while emphasizing the need for methodological standardization and expanded investigation of C. auris.
- 5 September 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 214
Open AccessAntimicrobial photodynamic therapy mediated by phenothiazine photosensitizers against Candida albicans and Candida auris: a systematic review
Fungal infections caused by Candida albicans and Candida auris represent an increasing clinical challenge, particularly due to biofilm formation and rising antifungal resistance. Antimicrobial photodynamic therapy (aPDT) has emerged as a potential alternative strategy, with phenothiazine-based photosensitizers being among the most extensively investigated compounds. This systematic review aimed to evaluate the application of phenothiazine-mediated aPDT in in vitro studies against C. albicans and C. auris . A comprehensive search was conducted in PubMed, Embase, and Scopus, including studies published within the last 10 years. Forty in vitro studies met the eligibility criteria and were synthesized descriptively due to substantial methodological heterogeneity. Overall, aPDT was associated with reductions in fungal viability, with generally greater effects reported in planktonic models compared with biofilms. Methylene blue was the most frequently investigated photosensitizer, applied across a broad range of concentrations and dosimetric parameters, resulting in variable antifungal responses. Other phenothiazine derivatives, including toluidine blue O, dimethyl methylene blue, new methylene blue, and S137, were also associated with antifungal activity under specific experimental conditions but remain comparatively underexplored. Studies involving C. auris were less frequent and suggested lower susceptibility compared with C. albicans , particularly in biofilm models. Given the substantial variability in experimental protocols, especially regarding photosensitizer concentration, light parameters, and biofilm maturation, the findings should be interpreted with caution and limit direct comparison across studies. These findings support the antifungal potential of phenothiazine-mediated aPDT while emphasizing the need for methodological standardization and expanded investigation of C. auris.
- Open Access
- 31 August 2026
- Published by Elsevier in International Orthodontics
- Vol. 24 (4)
Diagnostic performance of artificial intelligence for orthodontic and dentofacial assessment using 2D and 3D facial images: A systematic review
- 31 August 2026
- Published by Elsevier in International Orthodontics
- Vol. 24 (4)
Open AccessDiagnostic performance of artificial intelligence for orthodontic and dentofacial assessment using 2D and 3D facial images: A systematic review
- Open Access
- 28 July 2026
- Published by Caleo in European Endodontic Journal
Diagnostic Potential of Artificial Intelligence for Detecting Vertical Root Fractures on Dental Imaging: A Systematic Review and Diagnostic Meta-analysis
Vertical root fracture (VRF) remains a diagnostic challenge because radiographic signs are often subtle, non-specific and influenced by imaging modality, fracture characteristics, artefacts and observer interpretation. This systematic review and meta-analysis assessed the accuracy of artificial intelligence (AI)-based models for VRF detection on cone-beam computed tomography (CBCT), periapical radiographs and panoramic radiographs and evaluated the certainty of evidence. This review followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy Studies recommendations and was prospectively registered in International Prospective Register of Systematic Reviews. Studies evaluating AI-based models for VRF detection on dental imaging were included. Sensitivity and specificity were pooled using bivariate random-effects models when complete 2 × 2 contingency tables were available. Summary receiver operating characteristic curves were generated. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach adapted for diagnostic test accuracy. Post-hoc sensitivity analyses retained one representative dataset per study to assess the influence of multiple model-specific datasets. Six studies were included, of which 4 contributed to quantitative synthesis. The CBCT-based AI models showed high diagnostic performance under predominantly controlled or partially controlled conditions, with a pooled sensitivity of 85.3% and specificity of 89.0% (area under the curve [AUC]=0.921). The CBCT convolutional neural network–only subgroup showed sensitivity of 88.3% and specificity of 87.6% (AUC=0.929). Periapical radiograph-based models showed high sensitivity but limited specificity, with pooled sensitivity of 86.9% and specificity of 61.2% (AUC=0.708). The probabilistic neural network-only periapical subgroup improved sensitivity, but specificity remained limited. Sensitivity analyses confirmed preserved CBCT performance and persistently low periapical specificity. Panoramic radiography was assessed qualitatively because complete 2 × 2 data were unavailable. Certainty of evidence was moderate for CBCT and low for periapical radiographs. AI-based models show promising diagnostic potential for VRF detection, particularly on CBCT. However, current evidence mainly reflects performance under controlled or partially controlled conditions and should not be interpreted as definitive real-world diagnostic effectiveness. AI should currently be considered an adjunctive decision-support tool rather than an autonomous diagnostic method, especially for 2-dimensional imaging modalities. Prospective, multicentre clinical validation studies are needed.
- 28 July 2026
- Published by Caleo in European Endodontic Journal
Open AccessDiagnostic Potential of Artificial Intelligence for Detecting Vertical Root Fractures on Dental Imaging: A Systematic Review and Diagnostic Meta-analysis
Vertical root fracture (VRF) remains a diagnostic challenge because radiographic signs are often subtle, non-specific and influenced by imaging modality, fracture characteristics, artefacts and observer interpretation. This systematic review and meta-analysis assessed the accuracy of artificial intelligence (AI)-based models for VRF detection on cone-beam computed tomography (CBCT), periapical radiographs and panoramic radiographs and evaluated the certainty of evidence. This review followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy Studies recommendations and was prospectively registered in International Prospective Register of Systematic Reviews. Studies evaluating AI-based models for VRF detection on dental imaging were included. Sensitivity and specificity were pooled using bivariate random-effects models when complete 2 × 2 contingency tables were available. Summary receiver operating characteristic curves were generated. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 and certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach adapted for diagnostic test accuracy. Post-hoc sensitivity analyses retained one representative dataset per study to assess the influence of multiple model-specific datasets. Six studies were included, of which 4 contributed to quantitative synthesis. The CBCT-based AI models showed high diagnostic performance under predominantly controlled or partially controlled conditions, with a pooled sensitivity of 85.3% and specificity of 89.0% (area under the curve [AUC]=0.921). The CBCT convolutional neural network–only subgroup showed sensitivity of 88.3% and specificity of 87.6% (AUC=0.929). Periapical radiograph-based models showed high sensitivity but limited specificity, with pooled sensitivity of 86.9% and specificity of 61.2% (AUC=0.708). The probabilistic neural network-only periapical subgroup improved sensitivity, but specificity remained limited. Sensitivity analyses confirmed preserved CBCT performance and persistently low periapical specificity. Panoramic radiography was assessed qualitatively because complete 2 × 2 data were unavailable. Certainty of evidence was moderate for CBCT and low for periapical radiographs. AI-based models show promising diagnostic potential for VRF detection, particularly on CBCT. However, current evidence mainly reflects performance under controlled or partially controlled conditions and should not be interpreted as definitive real-world diagnostic effectiveness. AI should currently be considered an adjunctive decision-support tool rather than an autonomous diagnostic method, especially for 2-dimensional imaging modalities. Prospective, multicentre clinical validation studies are needed.
- Open Access
- 13 July 2026
- Published by Elsevier in International Orthodontics
- Vol. 24 (4) , 101211
Clinical, biomechanical, and digital factors associated with refinement after the first series of clear aligners: A systematic review
- 13 July 2026
- Published by Elsevier in International Orthodontics
- Vol. 24 (4) , 101211
Open AccessClinical, biomechanical, and digital factors associated with refinement after the first series of clear aligners: A systematic review
- Open Access
- 23 June 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70116
Artificial intelligence for detection and segmentation of accessory root canals in endodontic imaging: A systematic review
Accessory root canal anatomy, including second mesiobuccal (MB2) and middle mesial canals (MMC), is difficult to identify and may compromise endodontic outcomes when missed, supporting artificial intelligence (AI)‐based diagnostic tools. This systematic review (CRD420261415943) included studies evaluating AI models for accessory canal or root canal orifice identification, emphasizing MB2, MMC, and canal orifice detection. Study characteristics, imaging modalities, AI architectures, reference standards, outcomes, and validation strategies were extracted. Risk of bias was assessed using QUADAS‐2 and certainty of evidence using GRADE. Seven studies were included. Most evaluated MB2 detection or segmentation on cone‐beam computed tomography (CBCT); one assessed root canal orifice detection using dental operating microscope images, and one evaluated MMC detection. AI approaches included U‐Net, YOLO, CNN‐based pipelines, Inception V3‐based machine learning, ChatGPT‐4o, and nnU‐Net. For MB2 detection/classification, sensitivity or recall ranged from 80.0% to 100%, specificity from 99.4% to 100% when reported, accuracy from 84.9% to 97.8%, and area under the curve from 0.57 to approximately 0.90. Segmentation/localization outcomes were heterogeneous. AI shows promise as an adjunct for accessory canal detection, particularly MB2 on CBCT, but evidence remains limited.
- 23 June 2026
- Published by Wiley in European Journal of Oral Sciences
- p. e70116
Open AccessArtificial intelligence for detection and segmentation of accessory root canals in endodontic imaging: A systematic review
Accessory root canal anatomy, including second mesiobuccal (MB2) and middle mesial canals (MMC), is difficult to identify and may compromise endodontic outcomes when missed, supporting artificial intelligence (AI)‐based diagnostic tools. This systematic review (CRD420261415943) included studies evaluating AI models for accessory canal or root canal orifice identification, emphasizing MB2, MMC, and canal orifice detection. Study characteristics, imaging modalities, AI architectures, reference standards, outcomes, and validation strategies were extracted. Risk of bias was assessed using QUADAS‐2 and certainty of evidence using GRADE. Seven studies were included. Most evaluated MB2 detection or segmentation on cone‐beam computed tomography (CBCT); one assessed root canal orifice detection using dental operating microscope images, and one evaluated MMC detection. AI approaches included U‐Net, YOLO, CNN‐based pipelines, Inception V3‐based machine learning, ChatGPT‐4o, and nnU‐Net. For MB2 detection/classification, sensitivity or recall ranged from 80.0% to 100%, specificity from 99.4% to 100% when reported, accuracy from 84.9% to 97.8%, and area under the curve from 0.57 to approximately 0.90. Segmentation/localization outcomes were heterogeneous. AI shows promise as an adjunct for accessory canal detection, particularly MB2 on CBCT, but evidence remains limited.
- Open Access
- 18 June 2026
- Published by Elsevier in Dentistry Review
- Vol. 6 (3)
Diagnostic accuracy of deep learning models for the detection of pulpal calcifications in dental radiographs: A systematic review and meta-analysis
- 18 June 2026
- Published by Elsevier in Dentistry Review
- Vol. 6 (3)
Open AccessDiagnostic accuracy of deep learning models for the detection of pulpal calcifications in dental radiographs: A systematic review and meta-analysis