Chenxuan Hao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenxuan Hao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Lei Fan
Sun Yat-Sen University (Zhuhai Campus)
4 shared publications Wenjing Zhu
Sun Yat-Sen University (Zhuhai Campus)
4 shared publicationsYurong Huang
Sun Yat-Sen University (Zhuhai Campus)
4 shared publications- Yong Yan
Sun Yat-Sen University (Zhuhai Campus)
3 shared publications Xingyu Chen
Sun Yat-Sen University (Zhuhai Campus)
2 shared publicationsZizheng Li
Sun Yat-Sen University (Zhuhai Campus)
2 shared publications
Latest Publications
- 13 October 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (30) , 10430-10437
Diffraction-induced local longitudinal phase variations and their limited impact on the interferometric phase
Diffraction can affect precision interferometric displacement measurements by modifying the amplitude and phase of a propagated optical field in space-borne gravitational-wave detection systems. This work investigates the effect of diffraction on the phase variation induced by a small longitudinal displacement of the observation plane relative to the diffracting aperture, corresponding to a change in the distance that light propagates in free space, using the Rayleigh–Sommerfeld diffraction formulation. We find that the local phase response generally deviates from the geometric prediction, with the largest deviations occurring near diffraction-induced amplitude minima. However, these regions contribute little to the detected interferometric phase because of their low optical amplitudes, so the interferometric phase remains close to the geometric prediction. A residual phase is introduced to quantify the diffraction-induced correction. For millimeter-scale apertures and a representative gravitational-wave receiving system, the calculated residual phase for Δz=1pm is approximately 2×10 −10 rad, corresponding to a residual phase response of approximately 2×10 −10 rad/pm. Thus, diffraction introduces only a minor correction to longitudinal displacement measurements over the post-telescope propagation path. Unlike conventional analyses that characterize spatial phase distributions, the present work distinguishes the local longitudinal phase response from the detector-level interferometric phase. The results provide a quantitative basis for assessing diffraction-induced corrections in precision space-borne interferometric displacement measurements.
- 13 October 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (30) , 10430-10437
Diffraction-induced local longitudinal phase variations and their limited impact on the interferometric phase
Diffraction can affect precision interferometric displacement measurements by modifying the amplitude and phase of a propagated optical field in space-borne gravitational-wave detection systems. This work investigates the effect of diffraction on the phase variation induced by a small longitudinal displacement of the observation plane relative to the diffracting aperture, corresponding to a change in the distance that light propagates in free space, using the Rayleigh–Sommerfeld diffraction formulation. We find that the local phase response generally deviates from the geometric prediction, with the largest deviations occurring near diffraction-induced amplitude minima. However, these regions contribute little to the detected interferometric phase because of their low optical amplitudes, so the interferometric phase remains close to the geometric prediction. A residual phase is introduced to quantify the diffraction-induced correction. For millimeter-scale apertures and a representative gravitational-wave receiving system, the calculated residual phase for Δz=1pm is approximately 2×10 −10 rad, corresponding to a residual phase response of approximately 2×10 −10 rad/pm. Thus, diffraction introduces only a minor correction to longitudinal displacement measurements over the post-telescope propagation path. Unlike conventional analyses that characterize spatial phase distributions, the present work distinguishes the local longitudinal phase response from the detector-level interferometric phase. The results provide a quantitative basis for assessing diffraction-induced corrections in precision space-borne interferometric displacement measurements.
- 1 October 2026
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 43 (19) , 195003
Analysis of TTL coupling coefficients for a space gravitational-wave telescope under ground gravity field and recommended integration attitude selection
The tilt-to-length (TTL) coupling coefficient is a critical optical metric for a space gravitational-wave telescope. The transition from ground integration to on-orbit operation induces gravity release, which deforms the structure, distorts the wavefront, and significantly alters the TTL coefficient. To mitigate such variations, we extend the conventional polynomial model relating measured phase to aberrations and angular deviations, by introducing an equivalent defocus correction derived from Fresnel diffraction theory. This extension provides a rigorous basis for evaluating non-geometric TTL coupling under gravity-induced deformation. For an off-axis telescope meeting stringent mechanical specifications, we calculate TTL coefficients under - Y, X , and - Z direction gravity conditions. Results show that the X direction gravity case yields the lowest TTL coupling coefficients: the geometric TTL coefficient is 0.0090 pm nrad −1 , slightly higher than the zero-gravity value, while the non-geometric TTL coefficient is 0.1066 pm nrad −1 , significantly smaller than those for the - Y and - Z direction (1.0541 and 0.5523 pm nrad −1 ) cases, making it the recommended integration attitude. Notably, the non-geometric TTL distribution exhibits a small-angle rotation relative to the zero-gravity state, which is driven primarily by variations in the sixth Zernike coefficient (z6, associated with 45° astigmatism). Guided by TTL coefficient minimization, we determine the recommended ground integration attitude via analytical modeling and numerical simulation.
- 1 October 2026
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 43 (19) , 195003
Analysis of TTL coupling coefficients for a space gravitational-wave telescope under ground gravity field and recommended integration attitude selection
The tilt-to-length (TTL) coupling coefficient is a critical optical metric for a space gravitational-wave telescope. The transition from ground integration to on-orbit operation induces gravity release, which deforms the structure, distorts the wavefront, and significantly alters the TTL coefficient. To mitigate such variations, we extend the conventional polynomial model relating measured phase to aberrations and angular deviations, by introducing an equivalent defocus correction derived from Fresnel diffraction theory. This extension provides a rigorous basis for evaluating non-geometric TTL coupling under gravity-induced deformation. For an off-axis telescope meeting stringent mechanical specifications, we calculate TTL coefficients under - Y, X , and - Z direction gravity conditions. Results show that the X direction gravity case yields the lowest TTL coupling coefficients: the geometric TTL coefficient is 0.0090 pm nrad −1 , slightly higher than the zero-gravity value, while the non-geometric TTL coefficient is 0.1066 pm nrad −1 , significantly smaller than those for the - Y and - Z direction (1.0541 and 0.5523 pm nrad −1 ) cases, making it the recommended integration attitude. Notably, the non-geometric TTL distribution exhibits a small-angle rotation relative to the zero-gravity state, which is driven primarily by variations in the sixth Zernike coefficient (z6, associated with 45° astigmatism). Guided by TTL coefficient minimization, we determine the recommended ground integration attitude via analytical modeling and numerical simulation.
- 24 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (18) , 33042
Diffraction and field-dependent defocus effects on non-geometric tilt-to-length coupling in a gravitational wave interferometric receiving system
Non-geometric tilt-to-length (TTL) coupling in space-borne gravitational-wave interferometric receiving systems is sensitive to wavefront distortions. We investigate the combined effects of field-dependent aberration evolution and diffraction propagation using Fringe Zernike analysis and Rayleigh-Sommerfeld modeling. For the residual aberration distribution of the investigated four-mirror system, the defocus-related Z 4 term dominates: a variation of about 10 −5 λ over ±100 nrad increases the TTL coupling coefficient by nearly a factor of six. Diffraction propagation additionally introduces quadratic phase curvature and redistributes the field amplitude, thereby modifying the spatial weighting of the QPD phase response. These results show that field-dependent defocus evolution and diffraction-induced phase and amplitude changes should be considered jointly for accurate TTL prediction and optimization of receiving optical systems in future space gravitational-wave detectors.
- 24 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (18) , 33042
Diffraction and field-dependent defocus effects on non-geometric tilt-to-length coupling in a gravitational wave interferometric receiving system
Non-geometric tilt-to-length (TTL) coupling in space-borne gravitational-wave interferometric receiving systems is sensitive to wavefront distortions. We investigate the combined effects of field-dependent aberration evolution and diffraction propagation using Fringe Zernike analysis and Rayleigh-Sommerfeld modeling. For the residual aberration distribution of the investigated four-mirror system, the defocus-related Z 4 term dominates: a variation of about 10 −5 λ over ±100 nrad increases the TTL coupling coefficient by nearly a factor of six. Diffraction propagation additionally introduces quadratic phase curvature and redistributes the field amplitude, thereby modifying the spatial weighting of the QPD phase response. These results show that field-dependent defocus evolution and diffraction-induced phase and amplitude changes should be considered jointly for accurate TTL prediction and optimization of receiving optical systems in future space gravitational-wave detectors.
- 27 July 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (22) , 7555-7569
ASF-based method for DWS bias correction and non-geometric tilt-to-length estimation in a receiving telescope for gravitational wave detection
Optical aberrations of the telescope, which is the core payload in space-based gravitational wave detectors, introduce angular and ranging errors and consequently degrade interferometric measurement precision. In this work, we consider a receiving telescope and develop a measurement model based on the complex-amplitude point-spread function to quantify the impact of aberrations on differential wavefront sensing (DWS) for angular readout and on non-geometric tilt-to-length (TTL) coupling for ranging measurement. Numerical simulations show that the point spread function (PSF) centroid shift can be used to describe the DWS bias caused by aberrations, and that applying the proposed correction improves the angular readout accuracy by approximately 66.3% in the studied case. For non-geometric TTL, the zero-angle ASF phase with first-order correction provides a fast estimator whose agreement with the integral method improves with increasing Gaussian waist and reaches a mean accuracy of about 87.6% for waists not smaller than 2.5 mm. These results show that the proposed ASF-based method can serve as a practical approach for analyzing aberration-induced measurement errors and for supporting DWS correction and non-geometric TTL estimation in receiving telescopes for gravitational wave detection.
- 27 July 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (22) , 7555-7569
ASF-based method for DWS bias correction and non-geometric tilt-to-length estimation in a receiving telescope for gravitational wave detection
Optical aberrations of the telescope, which is the core payload in space-based gravitational wave detectors, introduce angular and ranging errors and consequently degrade interferometric measurement precision. In this work, we consider a receiving telescope and develop a measurement model based on the complex-amplitude point-spread function to quantify the impact of aberrations on differential wavefront sensing (DWS) for angular readout and on non-geometric tilt-to-length (TTL) coupling for ranging measurement. Numerical simulations show that the point spread function (PSF) centroid shift can be used to describe the DWS bias caused by aberrations, and that applying the proposed correction improves the angular readout accuracy by approximately 66.3% in the studied case. For non-geometric TTL, the zero-angle ASF phase with first-order correction provides a fast estimator whose agreement with the integral method improves with increasing Gaussian waist and reaches a mean accuracy of about 87.6% for waists not smaller than 2.5 mm. These results show that the proposed ASF-based method can serve as a practical approach for analyzing aberration-induced measurement errors and for supporting DWS correction and non-geometric TTL estimation in receiving telescopes for gravitational wave detection.
- Open Access
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
An accurate measurement method based on the multiple-differential principle for mirror surface degradation due to adhesive bonding
Optical adhesive bonding is extensively employed in precision optical manufacturing. However, adhesive shrinkage during curing can introduce optical surface figure distortion ranging from nanometers to several hundred nanometers. In precision applications, it is essential to isolate and quantify the mirror surface degradation attributable solely to bonding. Yet, measurement accuracy is often compromised by gravity and variations in testing conditions. To address this, this paper proposes a flip differential method and a rotational differential method, both based on a multiple-differential principle. Comparative experiments were performed. The results show measured distortions of (25.4 ± 1.6)nm and (22.5 ± 1.9)nm, respectively. According to the criterion for metrological compatibility, at a 95% confidence level, the difference between the measurements is less than twice the combined standard uncertainty of their difference, indicating that the two methods are consistent within their respective uncertainties and thus validating their accuracy. The rotational method offers safer and simpler operation than the flip differential method, demonstrating broad potential for testing large-aperture mirrors.
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAn accurate measurement method based on the multiple-differential principle for mirror surface degradation due to adhesive bonding
Optical adhesive bonding is extensively employed in precision optical manufacturing. However, adhesive shrinkage during curing can introduce optical surface figure distortion ranging from nanometers to several hundred nanometers. In precision applications, it is essential to isolate and quantify the mirror surface degradation attributable solely to bonding. Yet, measurement accuracy is often compromised by gravity and variations in testing conditions. To address this, this paper proposes a flip differential method and a rotational differential method, both based on a multiple-differential principle. Comparative experiments were performed. The results show measured distortions of (25.4 ± 1.6)nm and (22.5 ± 1.9)nm, respectively. According to the criterion for metrological compatibility, at a 95% confidence level, the difference between the measurements is less than twice the combined standard uncertainty of their difference, indicating that the two methods are consistent within their respective uncertainties and thus validating their accuracy. The rotational method offers safer and simpler operation than the flip differential method, demonstrating broad potential for testing large-aperture mirrors.